摘要
The tolerances for the alignment of the magnets in the girders of the next machine of the Brazilian Synchrotron Light Laboratory (LNLS), Sirius, are as small as 40 mu m for translations and 0.2 mrad for rotations. Therefore, a novel approach to the well-known vibrating wire technique has been developed and tested for the precise fiducialization of magnets. The alignment bench consists of four commercial linear stages, a stretched wire, a commercial lock-in amplifier working with phase-locked loop (PLL), a coordinate measuring machine (CMM) and a vibration sensor for the wire. This novel sensor has been designed for a larger linear region of operation. For the mechanical metrology step of the fiducialization of quadrupoles an innovative technique, using the vision system of the CMM, is presented. While the work with pitch and yaw orientations is still ongoing with promising partial results, the system already presents an uncertainty level below 10 mu m for translational alignment. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:115 / 123
页数:9
相关论文
共 50 条
  • [21] An evaluation of a non-contact biomotion sensor with actimetry
    Fox, Niall A.
    Heneghan, Conor
    Gonzalez, Monica
    Shouldice, Redmond B.
    de Chazal, Philip
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2664 - +
  • [22] PASSIVE NON-CONTACT AMORPHOUS SPEED SENSOR
    BUSHOFA, BMF
    MEYDAN, T
    IEEE TRANSACTIONS ON MAGNETICS, 1987, 23 (05) : 2197 - 2199
  • [23] A micro sensor for non-contact temperature measurement
    Li, XP
    Chan, WF
    MICROMACHINING AND MICROFABRICATION, 2000, 4230 : 66 - 75
  • [24] On a non-contact DC weak current sensor
    Liu, Lihong
    Wuhan Jiaotong Keji Daxue Xuebao/Journal of Wuhan Transportation University, 22 (03): : 298 - 300
  • [25] Use case of non-contact Caliper sensor
    Nozoe O.
    Totsuka S.
    Kami Pa Gikyoshi/Japan Tappi Journal, 2010, 64 (03): : 43 - 52
  • [26] Truly universal non-contact thickness sensor
    Burnett, C
    Carmichael, G
    Jardina, D
    ALUMINUM 2002, PROCEEDINGS, 2002, : 197 - 204
  • [27] Non-contact miniature lightning overvoltage sensor
    Zhang, Zhiguo
    Zhang, Wenbin
    Li, Hongsheng
    Suo, Chunguang
    FERROELECTRICS, 2019, 549 (01) : 184 - 194
  • [28] An Innovative Non-Contact ECG and Biopotential Sensor
    Sun, Y.
    Yu, X.
    Berilla, J.
    STRUCTURAL HEALTH MONITORING 2011: CONDITION-BASED MAINTENANCE AND INTELLIGENT STRUCTURES, VOL 2, 2013, : 2203 - 2211
  • [29] A non-contact broad bandwidth current sensor
    Zhang, Rui
    Zhang, Qiaogen
    Geng, Jiangtao
    Liu, Fuli
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (10)
  • [30] NON-CONTACT PNEUMATIC SENSOR BOLT.
    Bechtler, H.J.
    Cachon, R.
    O'Dell, R.
    IBM technical disclosure bulletin, 1985, 27 (08): : 4922 - 4923