Steady state and transient ampacities of gas-insulated transmission lines

被引:1
|
作者
Eteiba, MB [1 ]
机构
[1] Cairo Univ, Dept Elect Engn, Al Fayyum, Egypt
关键词
transmission lines; thermal rating; compressed gas cables; transient cable ampacity;
D O I
10.1109/MELECON.2002.1014622
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a thermal model for predicting the lady state and transient ampacities of gas-insulated transmission lines (GILs). Using the thermal model, a computer program has been formulated such that it can estimate the ampacity of a GIL for any time-varying or constant current loading and any variation in environmental conditions. Relations for the convection and radiation heat transfer coefficients for a GIL filled with Sulfur Heaxfluoride (SF(6)), nitrogen, or a gas mixture of both gases are presented. The validity and accuracy of the ampacity model were verified by comparing the predicted temperature of core, gas, and enclosure of the GIL with measured temperatures reported in the literature under the same conditions. Analytically predicted and experimentally measured values both show close agreement to each other. Moreover, Using a 50%-50% mixture of SF(6) and nitrogen resulted in a conductor temperature of only less than 1degreesC hotter than SF(6) alone.
引用
收藏
页码:424 / 428
页数:3
相关论文
共 50 条
  • [21] HEAT-TRANSFER CHARACTERISTICS OF GAS-INSULATED TRANSMISSION-LINES
    MINAGUCHI, D
    GINNO, M
    ITAKA, K
    FURUKAWA, H
    NINOMIYA, K
    HAYASHI, T
    IEEE TRANSACTIONS ON POWER DELIVERY, 1986, 1 (01) : 2 - 9
  • [22] Insulation co-ordination for Gas-Insulated Transmission Lines (GIL)
    Völcker, O
    Koch, H
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 703 - 711
  • [23] Insulation co-ordination for gas-insulated transmission lines (GIL)
    Völcker, O
    Koch, H
    IEEE TRANSACTIONS ON POWER DELIVERY, 2001, 16 (01) : 122 - 130
  • [24] Reliability assessment of EHV gas-insulated transmission lines: Effect of redundancies
    Benato, Roberto
    Napolitano, Domenico
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 2174 - 2181
  • [25] Gas-insulated transmission line (GIL)
    Koch, HJ
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 2480 - 2483
  • [26] Basic properties of hybrid gas-insulated transmission lines (H-GIL)
    Yashima, Masafumi
    Kawamoto, Tadashi
    Fujinami, Hideo
    Takuma, Tadasu
    Hata, Hiroyuki
    Yamaguchi, Hiroaki
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 1997, 119 (03): : 27 - 39
  • [27] Basic properties of hybrid gas-insulated transmission lines (H-GIL)
    Yashima, M
    Kawamoto, T
    Fujinami, H
    Takuma, T
    Hata, H
    Yamaguchi, H
    ELECTRICAL ENGINEERING IN JAPAN, 1997, 119 (03) : 27 - 39
  • [28] Seismic Performance Evaluation and Retrofit Strategy of Overhead Gas-Insulated Transmission Lines
    Li, Xiaoxuan
    Xie, Qiang
    Wen, Jiayi
    BUILDINGS, 2023, 13 (12)
  • [29] Environment-friendly Insulating Gases for HVDC Gas-insulated Transmission Lines
    Chen, Geng
    Tu, Youping
    Wang, Cong
    Wang, Jue
    Yuan, Zhikang
    Ma, Guoming
    Wang, Jian
    Qi, Bo
    Li, Chuanyang
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2021, 7 (03): : 510 - 529
  • [30] Thermal and magnetic analyses of gas-insulated lines
    Metwally, I. A.