Ambulatory blood pressure data is the best approximation of central aortic pressure in coarctation of aorta

被引:1
|
作者
Egbe, Alexander C. [1 ,2 ]
Miranda, William R. [1 ]
Connolly, Heidi M. [1 ]
Kullo, Iftikhar J. [1 ]
机构
[1] Mayo Clin, Dept Cardiovasc Med, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, 200 First St SW, Rochester, MN 55905 USA
来源
INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE | 2021年 / 4卷
关键词
Coarctation of aorta; Central aortic pressure; Blood pressure monitoring; CARDIOVASCULAR MAGNETIC-RESONANCE; VENTRICULAR DIASTOLIC FUNCTION; REPAIRED TETRALOGY; AMERICAN SOCIETY; FALLOT; PHYSIOLOGY; ECHOCARDIOGRAPHY; HEART; QUANTIFICATION; GUIDELINES;
D O I
10.1016/j.ijcchd.2021.100142
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of the study was to determine which out-of-office BP measurement modality has the best correlation with central aortic systolic BP, arterial stiffness (a determinant of central aortic pressure) and LV mass index (LVMI) which represents LV adaptation to elevated central aortic pressures. In this prospective study, we demonstrated that 24h ambulatory systolic BP has better correlation with central aortic systolic BP (arterial load) and LVMI as compared to home systolic BP. 24h ambulatory systolic BP also correlated with arterial stiffness (determinant of arterial load), although this correlation was comparable to that observed with home systolic BP. Collectively, these results suggest that ambulatory systolic BP provides the best approximation of arterial load, which is the underpinning hemodynamic stress leading to LV remodeling, end-organ dysfunction, and cardiovascular mortality in patients with COA. These findings provide a foundation for further studies to determine whether titrating antihypertensive therapy based on ambulatory BP indices will slow the progression of LV remodeling and end-organ dysfunction due to hypertension, and in turn, reduce cardiovascular death in this population.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] Association between ambulatory blood pressure values and central aortic pressure in a large population of normotensive and hypertensive patients
    Rouxinol-Dias, Ana
    Araujo, Sara
    Silva, Jose A.
    Barbosa, Loide
    Polonia, Jorge
    BLOOD PRESSURE MONITORING, 2018, 23 (01) : 24 - 32
  • [32] ASSOCIATION BETWEEN AMBULATORY BLOOD PRESSURE VALUES AND CENTRAL AORTIC PRESSURE IN LARGE POPULATION OF NORMOTENSIVE AND HYPERTENSIVE SUBJECTS
    Polonia, J.
    Rouxinol-Dias, A.
    Araujo, S.
    Silva, J.
    Barbosa, L.
    JOURNAL OF HYPERTENSION, 2017, 35 : E218 - E218
  • [33] EVALUATION OF EFFICACY AZILSARTAN MEDOXOMIL ON CENTRAL AORTIC BLOOD PRESSURE AND AMBULATORY BLOOD PRESSURE IN PATIENTS WITH MILD TO MODERATE ESSENTIAL HYPERTENSION
    Dobrokhod, A.
    Sirenko, Yu.
    Torbas, O.
    Granich, V.
    Kushnir, S.
    JOURNAL OF HYPERTENSION, 2017, 35 : E280 - E281
  • [34] Central aortic blood pressure measurements
    Christopher J Bulpitt
    C Rajkumar
    James D Cameron
    Journal of Human Hypertension, 2000, 14 : 531 - 531
  • [35] Central aortic blood pressure measurements
    Bulpitt, CJ
    Rajkumar, C
    Cameron, JT
    JOURNAL OF HUMAN HYPERTENSION, 2000, 14 (08) : 531 - 531
  • [36] Effect of stent implantation on blood pressure control in adults with coarctation of the aorta
    van der Burg, Jennifer J.
    Warmerdam, Evangeline G.
    Krings, Gregor J.
    Meijboom, Folkert J.
    van Dijk, Arie P.
    Post, Marco C.
    Veen, Gerrit
    Voskuil, Michiel
    Sieswerda, Gertjan Tj
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2018, 19 (08) : 944 - 950
  • [37] MRI of patients with increased blood pressure and altered blood pressure response after being operated for coarctation of the aorta
    Larsen, TH
    Taxt, A
    Segadal, L
    Greve, G
    Nordgard, G
    RADIOLOGY, 2001, 221 : 201 - 201
  • [38] Ambulatory blood pressure, left ventricular mass, and conduit artery function late after successful repair of coarctation of the aorta
    de Divitiis, M
    Pilla, C
    Kattenhorn, M
    Donald, A
    Zadinello, M
    Wallace, S
    Redington, A
    Deanfield, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (12) : 2259 - 2265
  • [39] Is the area under blood pressure curve the best parameter to evaluate 24-h ambulatory blood pressure monitoring data?
    Nobre, F
    Mion, D
    BLOOD PRESSURE MONITORING, 2005, 10 (05) : 263 - 270
  • [40] Ambulatory blood pressure monitoring after successful repair of coarctation of the aorta at mid-term follow-up
    Eroglu, AG
    Öztunç, EF
    JAPANESE HEART JOURNAL, 2000, 41 (01): : 49 - 58