Radiation hard programmable delay line for LHCb calorimeter upgrade

被引:3
|
作者
Mauricio, J. [1 ]
Gascon, D. [2 ]
Vilasis, X. [1 ]
Picatoste, E. [2 ]
Machefert, F. [3 ]
Lefrancois, J. [3 ]
Duarte, O. [3 ]
Beigbeder, C. [3 ]
机构
[1] Univ Ramon Llull, LIFAELS, Barcelona, Spain
[2] Univ Barcelona, ECM, ICC, Barcelona, Spain
[3] Univ Paris 11, CNRS, LAL, IN2P3, F-91405 Orsay, France
来源
关键词
VLSI circuits; Radiation-hard electronics; Front-end electronics for detector readout;
D O I
10.1088/1748-0221/9/01/C01016
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper describes the implementation of a SPI-programmable clock delay chip based on a Delay Locked Loop (DLL) in order to shift the phase of the LHC clock (25 ns) in steps of 1ns, with less than 5 ps jitter and 23 ps of DNL. The delay lines will be integrated into ICECAL, the LHCb calorimeter front-end analog signal processing ASIC in the near future. The stringent noise requirements on the ASIC imply minimizing the noise contribution of digital components. This is accomplished by implementing the DLL in differential mode. To achieve the required radiation tolerance several techniques are applied: double guard rings between PMOS and NMOS transistors as well as glitch suppressors and TMR Registers. This 5.7 mm(2) chip has been implemented in CMOS 0.35 mu m technology.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] A fiber-optic-based programmable delay line
    不详
    MICROWAVE JOURNAL, 1999, 42 (07) : 176 - +
  • [42] Towards Radiation Hard Sensor Materials for the CMS Tracker Upgrade
    Steinbrueck, Georg
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1828 - 1832
  • [43] Neutron induced radiation damage of plastic scintillators for the upgrade of the Tile Calorimeter of the ATLAS detector
    Mdhluli, J. E.
    Jivan, H.
    Erasmus, R.
    Davydov, Yu I.
    Baranov, V.
    Mthembu, S.
    Mellado, B.
    Sideras-Haddad, E.
    Solovyanov, O.
    Sandrock, C.
    Peter, G.
    Tlou, S.
    Khanye, N.
    Tjale, B.
    INTERNATIONAL WORKSHOP ON DISCOVERY PHYSICS AT THE LHC, 2017, 878
  • [44] A comparative study of the radiation hardness of plastic scintillators for the upgrade of the Tile Calorimeter of the ATLAS detector
    Liao, S.
    Erasmus, R.
    Jivan, H.
    Pelwan, C.
    Peters, G.
    Sideras-Haddad, E.
    HIGH ENERGY PARTICLE PHYSICS WORKSHOP (HEPPW2015), 2015, 645
  • [45] Design and implementation of programmable microwave delay line based on VXIbus
    Li, RT
    Wang, T
    Wang, XB
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 7233 - 7236
  • [46] PROGRAMMABLE PLANAR FOLDED PATH SAW DELAY-LINE
    CHO, FY
    HUNSINGER, BJ
    LEE, LL
    ENRIGHT, J
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1975, SU22 (03): : 214 - 214
  • [47] A LOW-COST PROGRAMMABLE DIGITAL DELAY-LINE
    LAKSHMINARAYANAN, V
    ELECTRONIC ENGINEERING, 1990, 62 (759): : 30 - 30
  • [48] PROGRAMMABLE, FLEXIBLE DELAY-LINE USES FEW PARTS
    RACHMILEVITCH, A
    ELECTRONIC DESIGN, 1988, 36 (18) : 126 - 127
  • [49] Beam Test Results of the RADiCAL-A Radiation Hard Innovative EM Calorimeter
    Wetzel, James
    Blend, Dylan
    Debbins, Paul
    Hermann, Max
    Koseyan, Ohannes Kamer
    Kamaran, Gurkan
    Onel, Yasar
    Anderson, Thomas
    Chigurupati, Nehal
    Cox, Brad
    Dubnowski, Max
    Ledovskoy, Alexander
    Perez-Lara, Carlos
    Barbera, Thomas
    Bostan, Nilay
    Ford, Kiva
    Jessop, Colin
    Ruchti, Randal
    Ruggiero, Daniel
    Smith, Daniel
    Vigneault, Mark
    Wan, Yuyi
    Wayne, Mitchell
    Hu, Chen
    Zhang, Liyuan
    Zhu, Ren-Yuan
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2023, 70 (07) : 1296 - 1300
  • [50] NEW RADIATION HARD PLASTICSCINTILLATOR UPS-98RH FOR HADRON CALORIMETER
    Senchishin, V. G.
    Lebedev, V. N.
    Khlapova, N. P.
    Adadurov, A. F.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2005, (03): : 160 - 163