Radiation hard programmable delay line for LHCb calorimeter upgrade

被引:3
|
作者
Mauricio, J. [1 ]
Gascon, D. [2 ]
Vilasis, X. [1 ]
Picatoste, E. [2 ]
Machefert, F. [3 ]
Lefrancois, J. [3 ]
Duarte, O. [3 ]
Beigbeder, C. [3 ]
机构
[1] Univ Ramon Llull, LIFAELS, Barcelona, Spain
[2] Univ Barcelona, ECM, ICC, Barcelona, Spain
[3] Univ Paris 11, CNRS, LAL, IN2P3, F-91405 Orsay, France
来源
关键词
VLSI circuits; Radiation-hard electronics; Front-end electronics for detector readout;
D O I
10.1088/1748-0221/9/01/C01016
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper describes the implementation of a SPI-programmable clock delay chip based on a Delay Locked Loop (DLL) in order to shift the phase of the LHC clock (25 ns) in steps of 1ns, with less than 5 ps jitter and 23 ps of DNL. The delay lines will be integrated into ICECAL, the LHCb calorimeter front-end analog signal processing ASIC in the near future. The stringent noise requirements on the ASIC imply minimizing the noise contribution of digital components. This is accomplished by implementing the DLL in differential mode. To achieve the required radiation tolerance several techniques are applied: double guard rings between PMOS and NMOS transistors as well as glitch suppressors and TMR Registers. This 5.7 mm(2) chip has been implemented in CMOS 0.35 mu m technology.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Crystal Fibers for the LHCb Calorimeter Upgrade
    Martinazzoli, Loris
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (06) : 1003 - 1008
  • [2] Electroweak measurements at LHCb with the calorimeter upgrade
    Arnone, L.
    Lucchesi, D.
    Sestini, L.
    Zuliani, D.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2024, 47 (05):
  • [3] The Phase 2 Upgrade of the LHCb Calorimeter system
    Guz, Yu
    JOURNAL OF INSTRUMENTATION, 2020, 15 (09):
  • [4] Study of a solution with COTS for the LHCb calorimeter upgrade
    Abellan Beteta, C.
    Gascon Fora, D.
    Picatoste Olloqui, E.
    Machefert, F.
    Lefrancois, J.
    Vilasis-Cardona, X.
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 2012, 37 : 1744 - 1749
  • [5] The Phase II upgrade of the LHCb calorimeter system
    Pizzichemi, M.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (05)
  • [6] The LHCb Calorimeter system: design, performance and upgrade
    Guz, Yu.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [7] Low noise front end ICECAL ASIC for the upgrade of the LHCb calorimeter
    Picatoste, E.
    Gascon, D.
    Abellan, C.
    Lefrancois, J.
    Machefert, F.
    Duarte, O.
    Grauges, E.
    Garrido, L.
    Vilasis, X.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [8] The LHCb VELO: Performance, Radiation Damage, and Upgrade
    Hennessy, Karol
    2013 3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION, MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2013,
  • [9] Cast Lead–Polystyrene Spaghetti Type Calorimeter for LHCb ECAL Upgrade II
    I. S. Diachkov
    Physics of Atomic Nuclei, 2023, 86 : 822 - 826
  • [10] OTIS - A radiation hard TDC for LHCb
    Deppe, H
    Feuerstack-Raible, M
    Stange, U
    Trunk, U
    Uwer, U
    PROCEEDINGS OF THE EIGHTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 2002, 2002 (03): : 87 - 90