DFIG wind turbine grid connected for frequency and amplitude control in a smart grid

被引:0
|
作者
Antonio Cortajarena, Jose [1 ]
De Marcos, Julian [1 ]
Alkorta, Patxi [1 ]
Barambones, Oscar [2 ]
Cortajarena, Jon [3 ]
机构
[1] Univ Basque Country, Eibar, Spain
[2] Univ Basque Country, Vitoria, Spain
[3] Univ Basque Country, Donostia San Sebastian, Spain
关键词
Doubly fed induction generator; droop control for grid frequency and voltage control; generator connection to grid; smart grid; INDUCTION-MACHINE; GENERATION; INVERTERS;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Power generated from wind is a fast growing renewable source of the world energy consumption. A double feed induction generator (DFIG) used in wind turbines, provides dynamic and static active and reactive power support. In this paper, the droop control technique is used to regulate the grid amplitude and frequency according to the criteria defined for the smart grid supervisor. Wind turbine will operate in an unloaded maximum power curve, and according to the reserved active power to correct the frequency deviation, the limit of the reactive power or voltage amplitude correction will be explained. In addition, the offset adjustment of the encoder and the stator synchronization and connection to the grid will be explained. The connection process to the grid and the regulation of a real 7.5kW DFIG is performed controlling the active and reactive powers to their reference values. For that, a platform based on a real-time interface with the DS1103 board is used.
引用
下载
收藏
页码:362 / 369
页数:8
相关论文
共 50 条
  • [31] A Robust Adaptive Controller for a DFIG Wind Turbine with Grid Voltage and Frequency Support
    Okou, Francis A.
    Akhrif, Ouassima
    Gauthier, Sebastien
    2010 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, 2010, : 572 - 577
  • [32] Supervisory control of a grid-connected wind turbine generator
    Achour, Djalloul
    Kesraoui, Mohamed
    Chaib, Ahmed
    WIND ENGINEERING, 2016, 40 (06) : 483 - 496
  • [33] Realization and control of a wind turbine connected to the grid by using PMSG
    Dahbi, Abdeldjalil
    Hachemi, Mabrouk
    Nait-Said, Nasreddine
    Nait-Said, Mohamed-Said
    ENERGY CONVERSION AND MANAGEMENT, 2014, 84 : 346 - 353
  • [34] Improved Control of Grid-connected DFIG-based Wind Turbine using Proportional-Resonant Regulators during Unbalanced Grid
    El Karkri, Yassir
    Rey-Boue, Alexis B.
    El Moussaoui, Hassan
    Stoeckl, Johannes
    Strasser, Thomas, I
    ENERGIES, 2019, 12 (21)
  • [35] Operation and control of a grid-connected DFIG-based wind turbine with series grid-side converter during network unbalance
    Yong Liao
    Hui Li
    Jun Yao
    Kai Zhuang
    ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (01) : 228 - 236
  • [36] Frequency Control in a Micro Grid with Wind Turbine System
    Shahrood, Amir Jalali
    Tafreshi, S. M. Moghaddas
    Viky, A. Houshmand
    Lahiji, Azim Saliminiaie
    Hamidi, Milad Moghassem
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 1116 - 1120
  • [37] Control Strategies for DFIG Based Grid Connected Wind Energy Conversion System
    Archna, Aggarwal
    Mohan, Saini Lalit
    Bhim, Singh
    INTERNATIONAL JOURNAL OF GRID AND DISTRIBUTED COMPUTING, 2014, 7 (03): : 49 - 60
  • [38] A Complete Control Startegy of DFIG Connected to The Grid for Wind Energy Conversion Systems
    Bakouri, Anass
    Mahmoudi, Hassane
    Barara, Mohamed
    Abbou, Ahmed
    Bennassar, Abderrahim
    Moutchou, Mohamed
    PROCEEDINGS OF 2015 3RD IEEE INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC'15), 2015, : 464 - 469
  • [39] Backstepping control of a wind energy conversion systems based on a DFIG connected to the grid
    Abdelhak, Ghalem
    Abdellatif, Naceri
    Youcef, Djeriri
    PRZEGLAD ELEKTROTECHNICZNY, 2023, 99 (12): : 98 - 103
  • [40] Modelling and Adaptive Control of a Wind Turbine for Smart Grid Applications
    Abo-Al-Ez, Khaled M.
    Tzoneva, Raynitchka
    PROCEEDINGS OF THE 13TH CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY, 2015, : 332 - 339