Comparison of near visual acuity and reading metrics in presbyopia correction

被引:28
|
作者
Gupta, Navneet [1 ]
Wolffsohn, James S. W. [1 ]
Naroo, Shehzad A. [1 ]
机构
[1] Aston Univ, Sch Life & Hlth Sci, Ophthalm Res Grp, Birmingham B4 7ET, W Midlands, England
来源
关键词
ACCOMMODATING INTRAOCULAR-LENS; CONTRAST SENSITIVITY; CLINICAL-EVALUATION; TEXT LEGIBILITY; IMPLANTATION; PERFORMANCE; VISION; RESTOR; CRYSTALENS; OUTCOMES;
D O I
10.1016/j.jcrs.2009.03.026
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To provide a consistent standard for the evaluation of different types of presbyopic correction. SETTING: Eye Clinic, School of Life and Health Sciences, Aston University, Birmingham, United Kingdom. METHODS: Presbyopic corrections examined were accommodating intraocular lenses (IOLs), simultaneous multifocal and monovision contact lenses, and varifocal spectacles. Binocular near visual acuity measured with different optotypes (uppercase letters, lowercase letters, and words) and reading metrics assessed with the Minnesota Near Reading chart (reading acuity, critical print size [CPS], CPS reading speed) were intercorrelated (Pearson product moment correlations) and assessed for concordance (intraclass correlation coefficients [ICC]) and agreement (Bland-Altman analysis) for indication of clinical usefulness. RESULTS: Nineteen accommodating IOL cases, 40 simultaneous contact lens cases, and 38 varifocal spectacle cases were evaluated. Other than CPS reading speed, all near visual acuity and reading metrics correlated well with each other (r>0.70, P<.001). Near visual acuity measured with uppercase letters was highly concordant (ICC, 0.78) and in close agreement with lowercase letters (+/- 0.17 logMAR). Near word acuity agreed well with reading acuity (+/- 0.16 logMAR), which in turn agreed well with near visual acuity measured with uppercase letters 0.16 logMAR). Concordance (ICC, 0.18 to 0.46) and agreement (+/- 0.24 to 0.30 logMAR) of CPS with the other near metrics was moderate. CONCLUSION: Measurement of near visual ability in presbyopia should be standardized to include assessment of near visual acuity with logMAR uppercase-letter optotypes, smallest logMAR print size that maintains maximum reading speed (CPS), and reading speed. J Cataract Refract Surg 2009; 35:1401-1409 (C) 2009 ASCRS and ESCRS
引用
收藏
页码:1401 / 1409
页数:9
相关论文
共 50 条
  • [21] Contribution of sVEP visual acuity testing in comparison with subjective visual acuity
    Vesely, Petr
    [J]. BIOMEDICAL PAPERS-OLOMOUC, 2015, 159 (04): : 616 - 621
  • [22] Comparison of distance and near visual acuity in patients with vision loss due to cataract
    Mercado, Carmel L.
    Doroslovacki, Pavle
    Wang, Jiangxia
    Siddiqui, Aazim A.
    Kolker, Andrew F.
    Kolker, Richard J.
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (01) : 169 - 172
  • [23] Comparison of distance and near visual acuity in patients with vision loss due to cataract
    Carmel L. Mercado
    Pavle Doroslovački
    Jiangxia Wang
    Aazim A. Siddiqui
    Andrew F. Kolker
    Richard J. Kolker
    [J]. International Ophthalmology, 2017, 37 : 169 - 172
  • [24] Prediction of visual acuity with combinations of wavefront aberration metrics
    Marsack, J
    Pesudovs, K
    Applegate, RA
    Thibos, LN
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U1000 - U1000
  • [25] Visual Acuity Results in low vision patients: Distance and near ETDRS charts vs. reading acuity with the MNREAD chart
    Mosheyev, AT
    Zlotina, A
    Aquilante, K
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U428 - U428
  • [26] EYE PREFERENCE, VISUAL ACUITY, AND READING ABILITY
    Spache, George
    [J]. ELEMENTARY SCHOOL JOURNAL, 1943, 43 (09): : 539 - 543
  • [27] Visual Acuity Reserve in Reading Chinese Newspapers
    Zhang, Jun
    Liu, Jingbo
    Suryakumar, Rajaraman
    Bullimore, Mark A.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [28] Topical lipoic acid choline ester eye drop for improvement of near visual acuity in subjects with presbyopia: a safety and preliminary efficacy trial
    Michael S. Korenfeld
    Stella M. Robertson
    Jerry M. Stein
    David G. Evans
    Steven H. Rauchman
    Kenneth N. Sall
    Subha Venkataraman
    Bee-Lian Chen
    Mark Wuttke
    William Burns
    [J]. Eye, 2021, 35 : 3292 - 3301
  • [29] Topical lipoic acid choline ester eye drop for improvement of near visual acuity in subjects with presbyopia: a safety and preliminary efficacy trial
    Korenfeld, Michael S.
    Robertson, Stella M.
    Stein, Jerry M.
    Evans, David G.
    Rauchman, Steven H.
    Sall, Kenneth N.
    Venkataraman, Subha
    Chen, Lian
    Wuttke, Mark
    Burns, William
    [J]. EYE, 2021, 35 (12) : 3292 - 3301
  • [30] VEGA-1: Phentolamine Ophthalmic Solution as a Single Agent Improves Distance-Corrected Near Visual Acuity in Patients with Presbyopia
    Katz, James
    Lazar, Eliot
    Kolli, Ajay
    Patel, Ronil
    Rahmani, Kavon
    Sooch, Mina
    Brigell, Mitchell G.
    Pepose, Jay Stuart
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)