Development and assessment of an optimized next-generation DNA sequencing approach for the mtgenome using the Illumina MiSeq

被引:87
|
作者
McElhoe, Jennifer A. [1 ]
Holland, Mitchell M. [1 ]
Makova, Kateryna D. [2 ]
Su, Marcia Shu-Wei [2 ]
Paul, Ian M. [3 ]
Baker, Christine H. [4 ]
Faith, Seth A. [4 ]
Young, Brian [4 ]
机构
[1] Penn State Univ, Forens Sci Program, University Pk, PA 16802 USA
[2] Penn State Univ, Dept Biol, University Pk, PA 16802 USA
[3] Penn State Coll Med, Dept Pediat, Hershey, PA 17033 USA
[4] Battelle Mem Inst, Columbus, OH 43201 USA
关键词
MiSeq; mtDNA; NextGENe; Heteroplasmy; Next-generation sequencing; Nextera; WHOLE MITOCHONDRIAL GENOME; FULLY AUTOMATED PROCESS; CONTROL REGION; ION TORRENT; HETEROPLASMY; MUTATIONS; CONSTRUCTION; RESOLUTION; PLATFORMS; AGREEMENT;
D O I
10.1016/j.fsigen.2014.05.007
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
The development of molecular tools to detect and report mitochondrial DNA (mtDNA) heteroplasmy will increase the discrimination potential of the testing method when applied to forensic cases. The inherent limitations of the current state-of-the-art, Sanger-based sequencing, including constrictions in speed, throughput, and resolution, have hindered progress in this area. With the advent of next-generation sequencing (NGS) approaches, it is now possible to clearly identify heteroplasmic variants, and at a much lower level than previously possible. However, in order to bring these approaches into forensic laboratories and subsequently as accepted scientific information in a court of law, validated methods will be required to produce and analyze NGS data. We report here on the development of an optimized approach to NGS analysis for the mtDNA genome (mtgenome) using the Illumina MiSeq instrument. This optimized protocol allows for the production of more than 5 gigabases of mtDNA sequence per run, sufficient for detection and reliable reporting of minor heteroplasmic variants down to approximately 0.5-1.0% when multiplexing twelve samples. Depending on sample throughput needs, sequence coverage rates can be set at various levels, but were optimized here for at least 5000 reads. In addition, analysis parameters are provided for a commercially available software package that identify the highest quality sequencing reads and effectively filter out sequencing-based noise. With this method it will be possible to measure the rates of low-level heteroplasmy across the mtgenome, evaluate the transmission of heteroplasmy between the generations of maternal lineages, and assess the drift of variant sequences between different tissue types within an individual. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:20 / 29
页数:10
相关论文
共 50 条
  • [31] A Review on Next-Generation Wildlife Monitoring using Environmental DNA (eDNA) Detection and Next-Generation Sequencing in Malaysia
    Othman, Nursyuhada
    Munian, Kaviarasu
    Haris, Hidayah
    Ramli, Farah Farhana
    Sariyati, Nur Hartini
    Najmuddin, Mohd Faudzir
    Abdul-Latiff, Muhammad Abu Bakar
    SAINS MALAYSIANA, 2023, 52 (01): : 17 - 33
  • [32] DEVELOPMENT OF MICROSATELLITES USING NEXT-GENERATION SEQUENCING FOR ACACIA CRASSICARPA
    McKinnon, G. E.
    Larcombe, M. J.
    Griffin, A. R.
    Vaillancourt, R. E.
    JOURNAL OF TROPICAL FOREST SCIENCE, 2018, 30 (02) : 252 - 258
  • [33] SNP Development in Penaeus vannamei via Next-Generation Sequencing and DNA Pool Sequencing
    Huang, Yongyu
    Zhang, Lili
    Ge, Hui
    Wang, Guodong
    Huang, Shiyu
    Yang, Zhangwu
    FISHES, 2021, 6 (03)
  • [34] Keeping Up with Advancing Technology in Next-Generation Sequencing (NGS): Validation of the Illumina MiSeq Platform for Use with a Previously Validated NGS Panel Test
    Blommel, J. H.
    Fadra, N.
    Peterson, L. M.
    Klee, E. W.
    Ferber, M. J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2013, 15 (06): : 846 - 846
  • [35] Massively parallel multiplex DNA sequencing for specimen identification using an Illumina MiSeq platform
    Shadi Shokralla
    Teresita M. Porter
    Joel F. Gibson
    Rafal Dobosz
    Daniel H. Janzen
    Winnie Hallwachs
    G. Brian Golding
    Mehrdad Hajibabaei
    Scientific Reports, 5
  • [36] DEVELOPMENT OF GATING NANOPORES FOR NEXT-GENERATION DNA SEQUENCING USING MECHANICALLY CONTROLLABLE BREAK JUNCTIONS
    Taniguchi, Masateru
    Kawai, Tomoji
    FLUID MEASUREMENTS AND INSTRUMENTATION CAVITATION AND MULTIPHASE FLOW ADVANCES IN FLUIDS ENGINEERING EDUCATION MICROFLUIDICS, VOL 2, 2012, : 335 - 338
  • [37] Development and characterization of 26 novel microsatellite loci for the trochid gastropod Gibbula divaricata (Linnaeus, 1758), using Illumina MiSeq next generation sequencing technology
    Lopez-Marquez, Violeta
    Garcia-Jimenez, Ricardo
    Templado, Jose
    Machordom, Annie
    PEERJ, 2016, 4
  • [38] Operationalizing Quality Assurance for Clinical Illumina Somatic Next-Generation Sequencing Pipelines
    Bridgers, Joshua
    Alexander, Kenyon
    Karsan, Aly
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2024, 26 (02): : 96 - 105
  • [39] Reproducibility of Clinical Samples by the Illumina TruSight Myeloid Next-generation Sequencing Panel
    Commander, L.
    Booker, J. K.
    Thorne, L. B.
    Gulley, M. L.
    Montgomery, N. D.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2018, 20 (06): : 918 - 918
  • [40] Detection of DNA Variation in RHD and RHCE using Next-Generation Sequencing
    Wheeler, M.
    Shaffer, T.
    Frazar, C.
    Huston, H.
    Fletcher, S. Nakaya
    Lannert, K.
    Harris, S.
    Nickerson, D.
    Delaney, M.
    Johnsen, J.
    TRANSFUSION, 2016, 56 : 18A - 18A