Development and assessment of an optimized next-generation DNA sequencing approach for the mtgenome using the Illumina MiSeq

被引:87
|
作者
McElhoe, Jennifer A. [1 ]
Holland, Mitchell M. [1 ]
Makova, Kateryna D. [2 ]
Su, Marcia Shu-Wei [2 ]
Paul, Ian M. [3 ]
Baker, Christine H. [4 ]
Faith, Seth A. [4 ]
Young, Brian [4 ]
机构
[1] Penn State Univ, Forens Sci Program, University Pk, PA 16802 USA
[2] Penn State Univ, Dept Biol, University Pk, PA 16802 USA
[3] Penn State Coll Med, Dept Pediat, Hershey, PA 17033 USA
[4] Battelle Mem Inst, Columbus, OH 43201 USA
关键词
MiSeq; mtDNA; NextGENe; Heteroplasmy; Next-generation sequencing; Nextera; WHOLE MITOCHONDRIAL GENOME; FULLY AUTOMATED PROCESS; CONTROL REGION; ION TORRENT; HETEROPLASMY; MUTATIONS; CONSTRUCTION; RESOLUTION; PLATFORMS; AGREEMENT;
D O I
10.1016/j.fsigen.2014.05.007
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
The development of molecular tools to detect and report mitochondrial DNA (mtDNA) heteroplasmy will increase the discrimination potential of the testing method when applied to forensic cases. The inherent limitations of the current state-of-the-art, Sanger-based sequencing, including constrictions in speed, throughput, and resolution, have hindered progress in this area. With the advent of next-generation sequencing (NGS) approaches, it is now possible to clearly identify heteroplasmic variants, and at a much lower level than previously possible. However, in order to bring these approaches into forensic laboratories and subsequently as accepted scientific information in a court of law, validated methods will be required to produce and analyze NGS data. We report here on the development of an optimized approach to NGS analysis for the mtDNA genome (mtgenome) using the Illumina MiSeq instrument. This optimized protocol allows for the production of more than 5 gigabases of mtDNA sequence per run, sufficient for detection and reliable reporting of minor heteroplasmic variants down to approximately 0.5-1.0% when multiplexing twelve samples. Depending on sample throughput needs, sequence coverage rates can be set at various levels, but were optimized here for at least 5000 reads. In addition, analysis parameters are provided for a commercially available software package that identify the highest quality sequencing reads and effectively filter out sequencing-based noise. With this method it will be possible to measure the rates of low-level heteroplasmy across the mtgenome, evaluate the transmission of heteroplasmy between the generations of maternal lineages, and assess the drift of variant sequences between different tissue types within an individual. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
下载
收藏
页码:20 / 29
页数:10
相关论文
共 50 条
  • [1] Concordance and reproducibility of a next generation mtGenome sequencing method for high-quality samples using the Illumina MiSeq
    Peck, Michelle A.
    Brandhagen, Michael D.
    Marshall, Charla
    Diegoli, Toni M.
    Irwin, Jodi A.
    Sturk-Andreaggi, Kimberly
    FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2016, 24 : 103 - 111
  • [2] NEXT GENERATION HLA SEQUENCING ON THE ILLUMINA MiSeq.
    Lind, Curt
    Duke, Jamie
    Ferriola, Deborah
    Mackiewicz, Katarzyna
    Papazoglou, Anna
    Heron, Steven
    Monos, Dimitri
    HUMAN IMMUNOLOGY, 2013, 74 : 136 - 136
  • [3] NEXT-GENERATION BISULFITE SEQUENCING OF CAC-NA1C WITH ILLUMINA MISEQ
    Dukal, Helene
    Schendel, Darja
    Lang, Maren
    Mossner, Maximilian
    Jann, Johann-Christoph
    Frank, Josef
    Treutlein, Jens
    Witt, Stephanie
    Rietschel, Marcella
    EUROPEAN NEUROPSYCHOPHARMACOLOGY, 2017, 27 : S445 - S445
  • [4] An efficient quantitation method of next-generation sequencing libraries by using MiSeq sequencer
    Katsuoka, Fumiki
    Yokozawa, Junji
    Tsuda, Kaoru
    Ito, Shin
    Pan, Xiaoqing
    Nagasaki, Masao
    Yasuda, Jun
    Yamamoto, Masayuki
    ANALYTICAL BIOCHEMISTRY, 2014, 466 : 27 - 29
  • [5] Next-generation DNA sequencing
    Shendure, Jay
    Ji, Hanlee
    NATURE BIOTECHNOLOGY, 2008, 26 (10) : 1135 - 1145
  • [6] Next-generation DNA sequencing
    Jay Shendure
    Hanlee Ji
    Nature Biotechnology, 2008, 26 : 1135 - 1145
  • [7] TOWARDS ALLELE LEVEL HLA GENOTYPING: A COMPARISON OF NEXT-GENERATION SEQUENCING PLATFORMS - ION TORRENT PGM AND ILLUMINA MISEQ
    Lind, Curt
    Mackiewicz, Kate
    Duke, Jamie
    Sasson, Ariella
    Mahoney, Stephen
    Rappaport, Eric
    Derbeneva, Olga
    Wallace, Doug
    Rozemuller, Erik
    Penning, Maarten
    Mulder, Wietse
    Monos, Dimitri
    HUMAN IMMUNOLOGY, 2012, 73 : 16 - 16
  • [8] Ligation Bias in Illumina Next-Generation DNA Libraries: Implications for Sequencing Ancient Genomes
    Seguin-Orlando, Andaine
    Schubert, Mikkel
    Clary, Joel
    Stagegaard, Julia
    Alberdi, Maria T.
    Luis Prado, Jose
    Prieto, Alfredo
    Willerslev, Eske
    Orlando, Ludovic
    PLOS ONE, 2013, 8 (10):
  • [9] Rapid development of microsatellite markers for the critically endangered Saiga (Saiga tatarica) using Illumina® Miseq next generation sequencing technology
    Carsten Nowak
    Steffen Zuther
    Sergey V. Leontyev
    Jutta Geismar
    Conservation Genetics Resources, 2014, 6 : 159 - 162
  • [10] Comparison of Analysis Pipelines for Next-Generation Sequencing Output from MiSeq
    Reddy, N. G.
    Haghshenas, V.
    Patel, K. P.
    Routbort, M. J.
    Luthra, R.
    Singh, R. R.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2013, 15 (06): : 944 - 945