Individually preformed titanium mesh implants for a true-to-original repair of orbital fractures

被引:76
|
作者
Schoen, R. [1 ]
Metzger, M. C. [1 ]
Zizelmann, C. [1 ]
Weyer, N. [1 ]
Schmelzeisen, R. [1 ]
机构
[1] Univ Freiburg, Dept Craniomaxillofacial Surg, D-79106 Freiburg, Germany
关键词
individual preformed mesh; orbital fracture; reconstruction; navigation aided procedure; osteosynthesis template; computer-assisted surgery;
D O I
10.1016/j.ijom.2006.06.018
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this investigation is to present the results using preoperatively-formed titanium mesh implants for a true-to-original primary repair of extensive orbital floor and medial wall fractures. Individually preformed implants were used to repair extensive orbital floor injuries in 19 patients at the University Hospital, Freiburg. The form of the orbital floor and walls was analysed by preoperative diagnostic CT scan data. The form of the virtual reconstructed orbit was transformed into a model of the orbital cavity by a template machine. Postoperative imaging by or CT scan verified the exact 3D reconstruction of the orbital cavity 'true to original'. None of the patients demonstrated diplopia or enophthalmos postoperatively. Using individually preformed titanium mesh implants, the accuracy of the 3D orbital reconstruction was within a range of 1 nun. The reconstruction using preformed implants proved to be less time consuming, more precise and less invasive, compared to 'free hand' efforts, for the repair of orbital injuries using titanium mesh and calvarial grafts.
引用
收藏
页码:990 / 995
页数:6
相关论文
共 50 条
  • [11] Use of Enophthalmic Implants in the Repair of Orbital Floor Fractures
    Kempster, R.
    Beigi, B.
    Galloway, G. D.
    ORBIT-AN INTERNATIONAL JOURNAL ON ORBITAL DISORDERS AND FACIAL RECONSTRUCTIVE SURGERY, 2005, 24 (04): : 219 - 225
  • [12] Porous polyethylene implants with embedded titanium mesh: Use in orbital fracture repair and computed tomography visualization
    Duss, CV
    Langer, PD
    Turbin, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [13] REPAIR OF ORBITAL BLOWOUT FRACTURES WITH MARLEX MESH AND GELFILM
    BURRES, SA
    COHN, AM
    MATHOG, RH
    LARYNGOSCOPE, 1981, 91 (11): : 1881 - 1886
  • [14] Use of Lorenz Titanium Implants in Orbital Fracture Repair
    Chang, Shu-Hong
    Custer, Philip L.
    Mohadjer, Yasaman
    Scott, Evan
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2009, 25 (02): : 119 - 122
  • [15] Comparison of Anatomical Preformed Titanium Implants and Patient-Specific CAD/CAM Implants in the Primary Reconstruction of Isolated Orbital Fractures-A Retrospective Study
    Pietzka, Sebastian
    Wenzel, Markus
    Winter, Karsten
    Wilde, Frank
    Schramm, Alexander
    Ebeling, Marcel
    Kasper, Robin
    Scheurer, Mario
    Sakkas, Andreas
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):
  • [16] Outcome of Precontoured Titanium Mesh in the Reconstruction of Orbital Blowout Fractures
    Munoli, Amarnath
    Bhanushali, Jinisha
    Jagannathan, Mukund
    INDIAN JOURNAL OF PLASTIC SURGERY, 2023, 56 (01) : 62 - 67
  • [17] Reconstruction of Isolated Orbital Floor Fractures with a Prefabricated Titanium Mesh
    Reich, W.
    Seidel, D.
    Bredehorn-Mayr, T.
    Eckert, A. W.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2014, 231 (03) : 246 - 255
  • [18] Cost Analysis of Implants in the Surgical Repair of Orbital Floor Fractures
    Mims, Mark M.
    Wang, Eric W.
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2020, 129 (05): : 456 - 461
  • [19] Repair of orbital floor fractures with bioactive glass implants - Discussion
    Mathog, RH
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 59 (12) : 1395 - 1396
  • [20] Orbital Adherence with Titanium Mesh Floor Implants: A Review of 10 Cases
    Kersey, Thomas L.
    Ng, Stephen G. J.
    Rosser, Paul
    Sloan, Brian
    Hart, Richard
    ORBIT-AN INTERNATIONAL JOURNAL ON ORBITAL DISORDERS AND FACIAL RECONSTRUCTIVE SURGERY, 2013, 32 (01): : 8 - 11