A comparison between the effect of systemic and coated drug delivery in osteoporotic bone after dental implantation

被引:2
|
作者
Ashrafi, Mehran [1 ]
Gholamian, Farzaneh [2 ]
Doblare, Manuel [1 ,3 ,4 ]
机构
[1] Univ Zaragoza, Aragon Inst Engn Res I3A, R&D Bldg,Block 5,1st Floor,Campus Rio Ebro,Mariano, Zaragoza 50018, Spain
[2] Sahand Univ Technol, Fac Biomed Engn, Tabriz, Iran
[3] Aragon Inst Hlth Res IIS Aragon, R&D Bldg,Block 5,1st Floor,Campus Rio Ebro,Mariano, Zaragoza 50018, Spain
[4] Ctr Invest Biomed Red Bioingn Biomat & Nanomed CIB, R&D Bldg,Block 5,1st Floor,Campus Rio Ebro,Mariano, Zaragoza 50018, Spain
关键词
Bone remodeling; Systemic drug delivery; Local drug delivery; Zoledronate; Finite element method; ZOLEDRONIC ACID; MICRODAMAGE ACCUMULATION; BIOMECHANICAL PROPERTIES; ORAL BISPHOSPHONATES; SODIUM ALENDRONATE; RANDOMIZED-TRIAL; MODEL; IBANDRONATE; OSSEOINTEGRATION; FIXATION;
D O I
10.1016/j.medengphy.2022.103859
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The increased life expectancy has boomed the demand of dental implants in the elderly. As a consequence, considering the effect of poorer bone quality, due to aging or associated diseases such as osteoporosis, on the success of dental restoration is becoming increasingly important. Bisphosphonates are one of the most used drugs to overcome the effect of osteoporosis as they increase bone density. Bisphosphonates modify the physiological bone remodeling process by adhering to the bone surface, reducing the activity of osteoclasts. This study aims at comparing the effect on bone remodeling of two drug delivery methods of Bisphosphonates: local delivery by coating the implant surface and systemic delivery. A chemo-mechano-biological bone remodeling model vali-dated in a previous paper was used here. The two drug delivery schemes were modeled by means of a finite element approach. In the systemic drug delivery case, the amount of drug that reaches the bone compartment was calculated using a pharmacokinetic model while in the local drug delivery system, the dose was calculated using Fickean diffusion. In particular, the effect of Zoledronate is studied here. The two drug delivery approaches are compared between them and with a control case with no drug. The results show that the use of Bisphosphonates increases the mechanical strength of bone, thus improving the implant fixation along time. Systemic drug delivery affects the entire skeleton, while local drug delivery only affects the area around the dental implant, which reduces the side effects of Bisphosphonates, such as increasing the mineral content, which may promote bone brittleness and microdamage far from the implant. These results support the conclusion that dental implants coated with Bisphosphonates can be a good solution for osteoporotic or low bone density patients without the long-term side effects of systemic drug delivery.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Bisphosphonate-coated BSA nanoparticles lack bone targeting after systemic administration
    Wang, Guilin
    Kucharski, Cezary
    Lin, Xiaoyue
    Uludag, Hasan
    JOURNAL OF DRUG TARGETING, 2010, 18 (08) : 611 - 626
  • [42] Comparison between sirolimus-coated and noncoated stent implantation in human coronary arteries
    Feres, F
    Costa, MA
    Abizaid, A
    Abizaid, AS
    Pinto, IMF
    Seixas, AC
    Staico, R
    Mattos, LAP
    Chaves, A
    Centemero, M
    Tanajura, LFL
    Falotico, R
    Jaeger, J
    Sousa, AGMR
    Eduardo, J
    Sousa, MR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 47A - 47A
  • [43] Computer modeling of drug delivery in the anterior human eye after subconjunctival and episcleral implantation
    Zhang, Feng
    Chen, Han
    Huang, Yukan
    COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 89 : 162 - 169
  • [44] Management of pericatheter cerebrospinal fluid leak after intrathecal implantation of a drug delivery system
    Singh, Prem K.
    Jain, Roopesh
    Mishra, Seema
    Kumar, Sunil
    Bhatnagar, Sushma
    Deo, Suryanand
    AMERICAN JOURNAL OF HOSPICE & PALLIATIVE MEDICINE, 2008, 25 (03): : 237 - 239
  • [45] Comparison in Sedative Effects between Dexmedetomidine and Midazolam in Dental Implantation: A Randomized Clinical Trial
    Wang, Li
    Zhou, Yi
    Zhang, Tiejun
    Huang, Lili
    Peng, Wei
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [46] Measuring Drug Therapy Effect on Osteoporotic Fracture Risk by Trabecular Bone Lacunarity: The LOTO Study
    Zaia, Annamaria
    Maponi, Pierluigi
    Sallei, Manuela
    Galeazzi, Roberta
    Scendoni, Pietro
    BIOMEDICINES, 2023, 11 (03)
  • [47] Comparison of bone biomechanical properties after bone marrow mesenchymal stem cell or alendronate treatment in an osteoporotic animal model
    Piao, Chengdong
    Li, Zhengwei
    Ding, Jie
    Kong, Daliang
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2019, 64 (06): : 721 - 727
  • [48] LUMBAR SPINE TO FOREARM RATIO OF BONE LOSS - COMPARISON BETWEEN HEALTHY AND OSTEOPOROTIC POSTMENOPAUSAL WOMEN
    ORTOLANI, S
    CARACENI, MP
    VERDOIA, C
    BIANCHI, ML
    TREVISAN, C
    ULIVIERI, FM
    CALCIFIED TISSUE INTERNATIONAL, 1986, 39 : A70 - A70
  • [49] Silica xerogel as an implantable carrier for controlled drug delivery - evaluation of drug distribution and tissue effects after implantation
    Kortesuo, P
    Ahola, M
    Karlsson, S
    Kangasniemi, I
    Yli-Urpo, A
    Kiesvaara, J
    BIOMATERIALS, 2000, 21 (02) : 193 - 198
  • [50] TRABECULAR BONE SCORE IN COMPARISON TO BONE MINERAL DENSITY IN DISCRIMINATION BETWEEN FEMALE POSTMENOPAUSAL PATIENTS WITH AND WITHOUT OSTEOPOROTIC FRACTURES
    Ignaszak-Szczepaniak, M.
    Michalak, M.
    OSTEOPOROSIS INTERNATIONAL, 2016, 27 : S525 - S526