The limits of the Pourbaix diagram in the interpretation of the kinetics of corrosion and cathodic protection of underground pipelines

被引:13
|
作者
Barthel, Juergen [1 ]
Deiss, Rainer [2 ]
机构
[1] Max Streicher GmbH & Co KG Aktien, Delitzsch, Germany
[2] Netze BW GmbH, Schelmenwasenstr 15, D-70567 Stuttgart, Germany
来源
关键词
Butler-Volmer equation; cathodic protection; corrosion protection; electrochemical kinetics; equilibrium thermodynamics; Nernst equation; newly proposed verification criteria; Pourbaix diagram; underground pipelines;
D O I
10.1002/maco.202011977
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This article deals with the basics of corrosion and corrosion protection, with the focus on equilibrium thermodynamics. Particular attention is paid to the easy-to-understand creation of Pourbaix diagrams, their uses, and limitations of this tool. In addition, the basics of electrochemical kinetics are dealt with to provide an overview of the possibilities and the interaction of both methods. Finally, it is argued that the globally recognized and practice-proven protection potential criteria remain valid.
引用
收藏
页码:434 / 445
页数:12
相关论文
共 50 条