Impact of the detector parameters on a Compton camera

被引:21
|
作者
Çonka-Nurdan, T [1 ]
Nurdan, K
Constantinescu, F
Freisleben, B
Pavel, NA
Walenta, AH
机构
[1] Ctr Adv European Studies & Res, CAESAR, D-53111 Bonn, Germany
[2] Univ Siegen, FB Phys, D-57068 Siegen, Germany
[3] Univ Siegen, FB Elektrotech & Informat, D-57068 Siegen, Germany
[4] Univ Bonn, Nukl Med Klin & Poliklin, D-53127 Bonn, Germany
关键词
In-113m; Compton camera; detector parameters; electronic collimation; emission tomography; silicon drift detector;
D O I
10.1109/TNS.2002.1039569
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Compton camera, in principle, can improve spatial resolution and efficiency with respect to today's PET and SPECT techniques. The optimization of a Compton camera system in terms of efficiency and resolution is a complex multi-parameter problem. The efficiency depends on various detector parameters (material, thickness, positioning, etc.). The influence of these parameters on the image reconstruction is investigated for a conventional reconstruction technique in order to find optimum detector parameters. The case studies are based on a model for a system consisting of a silicon drift detector (electron detector) and a scintillator detector (photon detector). Effects of secondary and background processes were not included in this model. It was found that high-energy gamma sources (300 keV and more) are preferable over lower-energy sources (e.g., 140 keV) commonly used for SPECT. A Si detector as an electron detector and an angular range between 30degrees and 80degrees is most useful considering the various physical and experimental constraints. Silicon drift detector (SDD) with integrated front-end electronics offers a very good energy resolution due to its low electronics noise. The intrinsic resolution of both detectors influence the overall resolution considerably. A relatively large pixel size of the SDD considered here reduces the number of readout channels, but also limits the intrinsic resolution. The thickness of the electron detector should be chosen in such a way that its effects on efficiency and spatial resolution are balanced. Interdetector distance of at least 15 cm was found to be appropriate for the detector setup considered in this paper.
引用
收藏
页码:817 / 821
页数:5
相关论文
共 50 条
  • [1] Effect of detector parameters on the image quality of Compton camera for 99mTc
    An, S. H.
    Seo, H.
    Lee, J. H.
    Lee, C. S.
    Lee, J. S.
    Kim, C. H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 251 - 254
  • [2] Performance evaluation of a table-top Compton camera for various detector parameters
    Lee, Se Hyung
    Seo, Hee
    An, So Hyun
    Lee, Jae Sung
    Kim, Chan Hyeong
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 88 - 91
  • [3] Characterisation of a clover detector - For the development of a compton camera
    Gros, S
    Norman, J
    Boston, A
    Cresswell, JR
    Hall, CJ
    Helsby, WI
    Lazarus, I
    Lewis, R
    Turk, G
    Mather, AR
    Nolan, PJ
    Berry, A
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 576 - 580
  • [4] Compton camera coincidences in the silicon drift detector
    Çonka-Nurdan, T
    Nurdan, K
    Walenta, AH
    Chiosa, I
    Freisleben, B
    Pavel, NA
    Strüder, L
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3839 - 3843
  • [5] A stacked CdTe pixel detector for a Compton camera
    Oonuki, Kousuke
    Tanaka, Takaaki
    Watanabe, Shin
    Takeda, Shin'ichiro
    Nakazawa, Kazuhiro
    Ushio, Masayoshi
    Mitani, Takefumi
    Takahashi, Tadayuki
    Tajima, Hiroyasu
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2): : 57 - 60
  • [6] Segmented germanium detector developments for Compton Camera application
    Piqueras, I
    Beck, FA
    Duchêne, G
    Medina, P
    Santos, C
    Villaumé, D
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 525 (1-2): : 275 - 278
  • [7] Detector Performance Effects on Compton Camera Data Quality
    Maggi, P.
    Peterson, S.
    Panthi, R.
    Mackin, D.
    Beddar, S.
    Polf, J.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E600 - E600
  • [8] Silicon detector for a Compton camera in nuclear medical imaging
    Meier, D
    Czermak, A
    Jalocha, P
    Sowicki, B
    Kowal, M
    Dulinski, W
    Mæhlum, G
    Nygård, E
    Yoshioka, K
    Fuster, J
    Lacasta, C
    Mikuz, M
    Roe, S
    Weilhammer, P
    Hua, CH
    Park, SJ
    Wildermann, SJ
    Zhang, L
    Clinthorne, NH
    Rogers, WL
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 812 - 816
  • [9] Silicon drift detector readout electronics for a Compton camera
    Nurdan, T
    Nurdan, K
    Walenta, AH
    Besch, HJ
    Fiorini, C
    Freisleben, B
    Pavel, NA
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 523 (03): : 435 - 440
  • [10] Sensitivity analysis of the efficiency of Compton camera to the detector parameters using the GEANT4 computer code
    Niknami, Mostafa
    Hosseini, Seyed Abolfazl
    Loushab, Mahdy Ebrahimi
    [J]. APPLIED RADIATION AND ISOTOPES, 2021, 176