Remote-Controlled Fully Implantable Neural Stimulator for Freely Moving Small Animal

被引:24
|
作者
Yun, Seunghyeon [1 ,2 ]
Koh, Chin Su [3 ]
Jeong, Joonsoo [4 ]
Seo, Jungmin [1 ,2 ]
Ahn, Seung-Hee [1 ,2 ]
Choi, Gwang Jin [1 ,2 ]
Shim, Shinyong [1 ,2 ]
Shin, Jaewoo [3 ]
Jung, Hyun Ho [3 ]
Chang, Jin Woo [3 ]
Kim, Sung June [1 ,2 ,5 ]
机构
[1] Seoul Natl Univ, Coll Engn, Dept Elect & Comp Engn, Seoul 08826, South Korea
[2] Seoul Natl Univ, Interuniv Semicond Res Ctr, Seoul 08826, South Korea
[3] Yonsei Univ, Coll Med, Dept Neurosurg, Seoul 03722, South Korea
[4] Pusan Natl Univ, Sch Med, Dept Biomed Engn, Yangsan 50612, South Korea
[5] Seoul Natl Univ, Coll Med, Inst Aging, Seoul 08826, South Korea
关键词
electrical stimulation; cortical stimulation; wireless telemetry; implantable neural stimulator; polymer packaging; ELECTRICAL-STIMULATION; BRAIN-STIMULATION; TELEMETRY SYSTEM; RAT NAVIGATION; RECORDINGS; POTENTIALS; PLASTICITY; DOPAMINE; RELEASE; RADIO;
D O I
10.3390/electronics8060706
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The application of a neural stimulator to small animals is highly desired for the investigation of electrophysiological studies and development of neuroprosthetic devices. For this purpose, it is essential for the device to be implemented with the capabilities of full implantation and wireless control. Here, we present a fully implantable stimulator with remote controllability, compact size, and minimal power consumption. Our stimulator consists of modular units of (1) a surface-type cortical array for inducing directional change of a rat, (2) a depth-type array for providing rewards, and (3) a package for accommodating the stimulating electronics, a battery and ZigBee telemetry, all of which are assembled after independent fabrication and implantation using customized flat cables and connectors. All three modules were packaged using liquid crystal polymer (LCP) to avoid any chemical reaction after implantation. After bench-top evaluation of device functionality, the stimulator was implanted into rats to train the animals to turn to the left (or right) following a directional cue applied to the barrel cortex. Functionality of the device was also demonstrated in a three-dimensional (3D) maze structure, by guiding the rats to better navigate in the maze. The movement of the rat could be wirelessly controlled by a combination of artificial sensation evoked by the surface electrode array and reward stimulation. We could induce rats to turn left or right in free space and help their navigation through the maze. The polymeric packaging and modular design could encapsulate the devices with strict size limitations, which made it possible to fully implant the device into rats. Power consumption was minimized by a dual-mode power-saving scheme with duty cycling. The present study demonstrated feasibility of the proposed neural stimulator to be applied to neuroprosthesis research.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Fully remote-controlled system for 3 MV ultra-high voltage electron microscope
    Hayashi, S
    Katsuta, T
    Matsui, I
    Takaoka, A
    ELECTRON MICROSCOPY 1998, VOL 1: GENERAL INTEREST AND INSTRUMENTATION, 1998, : 279 - 280
  • [32] Wireless-controlled cubic neural stimulator for free-moving animals
    Liu, Xinyu
    Su, Zhenling
    Gao, Qingran
    Ping, Yanna
    Xie, Hang
    Yang, Yang
    Wang, Dongyun
    ROYAL SOCIETY OPEN SCIENCE, 2023, 10 (03):
  • [33] Wireless Compact Neural Interface for Freely Moving Animal Subjects: A Review on Wireless Neural Interface SoC Designs
    Zhang M.
    Zhao Z.
    Ma Y.
    Zhang C.
    Song W.
    Lei J.
    Xie C.
    IEEE Solid-State Circuits Magazine, 2023, 15 (04): : 20 - 29
  • [34] Towards chronic deep brain stimulation in freely moving hemiparkinsonian rats: applicability and functionality of a fully implantable stimulation system
    Apetz, Nadine
    Paralikar, Kunal
    Neumaier, Bernd
    Drzezga, Alexander
    Wiedermann, Dirk
    Iyer, Rajesh
    Munns, Gordon
    Scott, Erik
    Timmermann, Lars
    Endepols, Heike
    JOURNAL OF NEURAL ENGINEERING, 2021, 18 (03)
  • [35] Fully flexible implantable neural probes for electrophysiology recording and controlled neurochemical modulation
    Malekoshoaraie, Mohammad Hassan
    Wu, Bingchen
    Krahe, Daniela D.
    Ahmed, Zabir
    Pupa, Stephen
    Jain, Vishal
    Cui, Xinyan Tracy
    Chamanzar, Maysamreza
    MICROSYSTEMS & NANOENGINEERING, 2024, 10 (01):
  • [36] Design, implementation and testing of an implantable impedance-based feedback-controlled neural gastric stimulator
    Arriagada, A. J.
    Jurkov, A. S.
    Neshev, E.
    Muench, G.
    Andrews, C. N.
    Mintchev, M. P.
    PHYSIOLOGICAL MEASUREMENT, 2011, 32 (08) : 1103 - 1115
  • [37] AN IMPLANTABLE MYOGRAPHY ELECTRODE FOR RECORDING MUSCLE-ACTIVITY IN FREELY MOVING SMALL ANIMALS - A NEW TECHNOLOGICAL APPROACH
    SIGRIST, GVM
    KLEINEBECKEL, DKE
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1982, 29 (11) : 730 - 736
  • [38] Clinical use of fully remote-controlled retinal optical coherence tomography (OCT) during the COVID-19 pandemic
    Straub, Jochen
    Callan, Thomas
    Makedonsky, Katherine
    Sha, Patricia
    Malvania, Pranav
    Durbin, Mary K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [39] Attenuation correction for freely moving small animal brain PET studies based on a virtual scanner geometry
    Angelis, G. I.
    Kyme, A. Z.
    Ryder, W. J.
    Fulton, R. R.
    Meikle, S. R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (19): : 5651 - 5666
  • [40] ONE-YEAR TRIAL OF A REMOTE-CONTROLLED IMPLANTABLE INSULIN INFUSION SYSTEM IN TYPE-I DIABETIC-PATIENTS
    HEPP, KD
    LANCET, 1988, 2 (8616): : 866 - 869