Can large-area avalanche photodiodes be used for a clinical PET/MRI block detector?

被引:0
|
作者
Peng, Hao [1 ]
Olcott, P. D. [1 ]
Spanoudaki, Virginia [1 ]
Levin, Craig S. [1 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
PET DETECTOR; SYSTEM;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We are investigating a high resolution, Angerlogic based PET block detector using large-area avalanche photodiodes (LAAPD). Such block detectors will be used in a simultaneous PET/MRI clinical scanner. Using a Monte-Carlo simulation tool, we systemically optimized the detector design taking into account the following factors: the dimensions of the scintillation crystal and the optical diffuser, the surface finish of crystals, the layout of APD arrays, and the signal-to-noise (SNR) of the system. Based on the simulation results, a block detector prototype was built with an 8x8 LYSO crystal array (crystal pitch size: 2.75 x 3.00 x 20 mm(3)) coupled to four APDs. The performance of the block detector with regard to the crystal resolving ability and the energy resolution is reported.
引用
收藏
页码:3948 / 3953
页数:6
相关论文
共 50 条
  • [41] Electrical characteristics and radiation detection performance of large-area photodiodes
    Bae, Jae Beom
    Hyun, Hyo Jung
    Kah, Dong Ha
    Kang, Kook Hyun
    Park, Hwan Bae
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (07) : 1418 - 1421
  • [42] Implementation of Noise Spectroscopy Using Biased Large-Area Photodiodes
    Langeveld, Willem G. J.
    Condron, Cathie
    Elsalim, Mashal
    Grudberg, Peter
    Hu, Victor
    Ryge, Peter
    Shaw, Tim
    Sinha, Shrabani
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 937 - 945
  • [43] LARGE-AREA GERMANIUM DETECTOR FOR RECTILINEAR SCANNING
    KRANER, HW
    LLACER, J
    ATKINS, HL
    RADIOLOGY, 1973, 106 (02) : 425 - 431
  • [44] Investigation of position sensitive avalanche photodiodes for a new high resolution PET detector design
    Levin, CS
    Foudray, AMK
    Olcott, PD
    Habte, F
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2262 - 2266
  • [45] Application of large area avalanche photodiodes for alpha liquid scintillation counting
    Reboli, A
    Aupiais, J
    Mialocq, JC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 550 (03): : 593 - 602
  • [46] Large area avalanche photodiodes in X-rays and light detection
    Moszynski, M
    Szawlowski, M
    Kapusta, M
    Balcerzyk, M
    Wolski, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) : 1297 - 1302
  • [47] Low energy γ-rays scintillation detection with Large Area Avalanche Photodiodes
    Soltan Inst for Nuclear Studies, Swierk-Otwock, Poland
    IEEE Trans Nucl Sci, 4 I (880-885):
  • [48] Response of large area avalanche photodiodes to low energy x rays
    Gentile, T. R.
    Bales, M.
    Arp, U.
    Dong, B.
    Farrell, R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (05):
  • [49] Magnetic field effects on large area avalanche photodiodes at cryogenic temperatures
    Gentile, T. R.
    Bass, C. D.
    Nico, J. S.
    Breuer, H.
    Farrell, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 520 - 523
  • [50] Large Area Avalanche Photodiodes in X-rays and scintillation detection
    Moszynski, M
    Kapusta, M
    Balcerzyk, M
    Szawlowski, M
    Wolski, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3): : 230 - 237