Automatic protective ventilation using the ARDSNet protocol with the additional monitoring of electrical impedance tomography

被引:17
|
作者
Pomprapa, Anake [1 ]
Schwaiberger, David [2 ,3 ]
Pickerodt, Philipp [2 ,3 ]
Tjarks, Onno [2 ,3 ]
Lachmann, Burkhard [2 ,3 ]
Leonhardt, Steffen [1 ]
机构
[1] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, Philips Chair Med Informat Technol, D-52074 Aachen, Germany
[2] Campus Charite Mitte, Dept Anesthesiol & Intens Care Med, D-13353 Berlin, Germany
[3] Charite, Campus Virchow Klinikum, D-13353 Berlin, Germany
来源
CRITICAL CARE | 2014年 / 18卷 / 03期
关键词
ACUTE RESPIRATORY-DISTRESS; ACUTE LUNG INJURY; MECHANICAL VENTILATION; FEASIBILITY; SURVIVORS; FEATURES; OUTCOMES; MODEL;
D O I
10.1186/cc13937
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Automatic ventilation for patients with respiratory failure aims at reducing mortality and can minimize the workload of clinical staff, offer standardized continuous care, and ultimately save the overall cost of therapy. We therefore developed a prototype for closed-loop ventilation using acute respiratory distress syndrome network (ARDSNet) protocol, called autoARDSNet. Methods: A protocol-driven ventilation using goal-oriented structural programming was implemented and used for 4 hours in seven pigs with lavage-induced acute respiratory distress syndrome ( ARDS). Oxygenation, plateau pressure and pH goals were controlled during the automatic ventilation therapy using autoARDSNet. Monitoring included standard respiratory, arterial blood gas analysis and electrical impedance tomography (EIT) images. After 2-hour automatic ventilation, a disconnection of the animal from the ventilator was carried out for 10 seconds, simulating a frequent clinical scenario for routine clinical care or intra-hospital transport. Results: This pilot study of seven pigs showed stable and robust response for oxygenation, plateau pressure and pH value using the automated system. A 10-second disconnection at the patient-ventilator interface caused impaired oxygenation and severe acidosis. However, the automated protocol-driven ventilation was able to solve these problems. Additionally, regional ventilation was monitored by EIT for the evaluation of ventilation in real-time at bedside with one prominent case of pneumothorax. Conclusions: We implemented an automatic ventilation therapy using ARDSNet protocol with seven pigs. All positive outcomes were obtained by the closed-loop ventilation therapy, which can offer a continuous standard protocol-driven algorithm to ARDS subjects.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Electrical impedance tomography as a tool for monitoring mechanical ventilation. An introduction to the technique
    Maciejewski, Dariusz
    Putowski, Zbigniew
    Czok, Marcelina
    Krzych, Lukasz J.
    ADVANCES IN MEDICAL SCIENCES, 2021, 66 (02): : 388 - 395
  • [22] Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography
    Frerichs, I
    Hahn, G
    Golisch, W
    Kurpitz, M
    Burchardi, H
    Hellige, G
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1998, 42 (06) : 721 - 726
  • [23] Electrical Impedance Tomography: A Monitoring Tool for Ventilation-induced Lung Injury
    Fratti, Isabella
    Pozzi, Tommaso
    Hahn, Guenter
    Fioccola, Antonio
    Nicolardi, Rosmery V.
    Busana, Mattia
    Collino, Francesca
    Moerer, Onnen
    Camporota, Luigi
    Gattinoni, Luciano
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209 (12) : 1510 - 1513
  • [24] Monitoring of Regional Lung Ventilation Using Electrical Impedance Tomography After Cardiac Surgery in Infants and Children
    Ulrich Krause
    Kristin Becker
    Günter Hahn
    Jörg Dittmar
    Wolfgang Ruschewski
    Thomas Paul
    Pediatric Cardiology, 2014, 35 : 990 - 997
  • [25] Monitoring of Regional Lung Ventilation Using Electrical Impedance Tomography After Cardiac Surgery in Infants and Children
    Krause, Ulrich
    Becker, Kristin
    Hahn, Guenter
    Dittmar, Joerg
    Ruschewski, Wolfgang
    Paul, Thomas
    PEDIATRIC CARDIOLOGY, 2014, 35 (06) : 990 - 997
  • [26] Electrical impedance tomography guided ventilation therapy
    Putensen, Christian
    Wrigge, Hermann
    Zinserling, Joerg
    CURRENT OPINION IN CRITICAL CARE, 2007, 13 (03) : 344 - 350
  • [27] Electrical Impedance Tomography During Mechanical Ventilation
    Walsh, Brian K.
    Smallwood, Craig D.
    RESPIRATORY CARE, 2016, 61 (10) : 1417 - 1424
  • [28] Monitoring changes in distribution of pulmonary ventilation by functional electrical impedance tomography in anaesthetized ponies
    Auer, Ulrike
    Schramel, J. Peter
    Moens, Yves P.
    Mosing, Martina
    Braun, Christina
    VETERINARY ANAESTHESIA AND ANALGESIA, 2019, 46 (02) : 200 - 208
  • [29] BETS - a bladder monitoring system using electrical impedance tomography
    Baran, Bartlomiej
    Wojcik, Dariusz
    Oleszek, Michal
    Vejar, Andres
    Rymarczyk, Tomasz
    PROCEEDINGS OF THE TWENTIETH ACM CONFERENCE ON EMBEDDED NETWORKED SENSOR SYSTEMS, SENSYS 2022, 2022, : 804 - 805
  • [30] Monitoring lungs with electrical impedance tomography
    Bevilacqua, Joyce Da Silva
    Yoshikawaz, Roberto Masaishi
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2007, 15 (04) : 325 - 337