An international key comparison of free-field hydrophone calibrations in the frequency range 1 to 500 kHz

被引:22
|
作者
Robinson, Stephen P. [1 ]
Harris, Peter M.
Ablitt, Justin
Hayman, Gary
Thompson, Alex
van Buren, A. Lee
Zalesak, Joseph F.
Drake, Robert M.
Isaev, Alexander E.
Enyakov, Alexander M.
Purcell, Christopher
Zhu Houqing
Wang Yuebing
Zhang Yue
Botha, Pierre
Krueger, Dieter
机构
[1] Natl Phys Lab, Teddington TW11 0LW, Middx, England
[2] USN, Undersea Warfare Ctr, USRD, Newport, RI 02841 USA
[3] VNIIFTRI, Moscow 141570, Russia
[4] Def Res & Dev Canada, Dartmouth, NS B2Y 3Z7, Canada
[5] Natl Inst Metrol, Acoust Lab, Beijing 100013, Peoples R China
[6] CSIR, Natl Metrol Lab, ZA-0001 Pretoria, South Africa
[7] Wehrtech Dienstelle Schiffe & Marinewaffen, D-24340 Eckernforde, Germany
来源
关键词
D O I
10.1121/1.2228790
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A description is given of the results of a Key Comparison of primary free-field standards for underwater acoustics at frequencies from 1 to 500 kHz. This is the first such Key Comparison exercise in the field of underwater acoustic calibration and measurement. Laboratories from UK, Germany, USA, Russia, China, Canada, and South Africa participated by calibrating three reference hydrophones, with project coordination provided by the National Physical Laboratory, UK. The agreement between the results obtained from the comparison was generally encouraging, with the calibration values reported by the laboratories agreeing within quoted uncertainties over the majority of the frequency range, and the results generally lying within a 0.5-dB band for frequencies up to 300 kHz. A discussion is given of the general sources of uncertainties in the calibrations, in particular those which are thought to have contributed to the differences in the results between laboratories. The results of the participants have been used to estimate the equivalence of national measurement standards within this field.
引用
收藏
页码:1366 / 1373
页数:8
相关论文
共 30 条
  • [1] An international key comparison of free-field hydrophone calibrations in the frequency range 1 to 500 kHz
    Robinson, Stephen P.
    Harris, Peter M.
    Ablitt, Justin
    Hayman, Gary
    Thompson, Alex
    Van Buren, A. Lee
    Zalesak, Joseph F.
    Drake, Robert M.
    Isaev, Alexander E.
    Enyakov, Alexander M.
    Purcell, Christopher
    Houqing, Zhu
    Yuebing, Wang
    Yue, Zhang
    Botha, Pierre
    Krüger, Dieter
    [J]. Journal of the Acoustical Society of America, 2006, 120 (03): : 1366 - 1373
  • [2] International comparison of free-field hydrophone calibrations in the frequency range 10 kHz to 315 kHz
    Robinson, SP
    Green, GJ
    Preston, RC
    [J]. METROLOGIA, 1999, 36 (04) : 287 - 296
  • [3] COOMET.AUV.W-S1 supplementary comparison of free-field hydrophone calibrations in the frequency range 250 Hz to 8 kHz
    Isaev, A. E.
    Yi, Chen
    Matveev, A. N.
    Ping Zihong
    [J]. METROLOGIA, 2015, 52
  • [4] Comparison of hydrophone calibration by reciprocity and heterodyne interferometer in the frequency range 500 kHz to 15 MHz
    Xing, Guangzhen
    Yang, Ping
    He, Longbiao
    [J]. MEASUREMENT TECHNOLOGY AND ITS APPLICATION, PTS 1 AND 2, 2013, 239-240 : 10 - 15
  • [5] Interlaboratory Comparisons of Hydrophone Calibration in the 3–500 kHz Frequency Range
    A. Malarkodi
    G. Latha
    M. A. Atmanand
    A. E. Isaev
    A. N. Matveev
    N. G. Shcherbliuk
    F. Mann
    C. Jansen
    D. Milkert
    [J]. Measurement Techniques, 2016, 59 : 99 - 103
  • [6] Measurement Uncertainty in Microphone Free-Field Comparison Calibrations
    Garg, N.
    Surendran, P.
    Dhanya, M. P.
    Chandran, A. T.
    Asif, M.
    Singh, M.
    [J]. MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2019, 34 (03): : 357 - 369
  • [7] Measurement Uncertainty in Microphone Free-Field Comparison Calibrations
    N. Garg
    P. Surendran
    M. P. Dhanya
    A. T. Chandran
    M. Asif
    M. Singh
    [J]. MAPAN, 2019, 34 : 357 - 369
  • [8] COOMET Pilot Comparison 473/RU-a/09: Comparison of hydrophone calibrations in the frequency range 250 Hz to 200 kHz
    Yi, Chen
    Isaev, A. E.
    Wang Yuebing
    Enyakov, A. M.
    Teng, Fei
    Matveev, A. N.
    [J]. METROLOGIA, 2011, 48
  • [9] Interlaboratory Comparisons of Hydrophone Calibration in the 3-500 kHz Frequency Range
    Malarkodi, A.
    Latha, G.
    Atmanand, M. A.
    Isaev, A. E.
    Matveev, A. N.
    Shcherbliuk, N. G.
    Mann, F.
    Jansen, C.
    Milkert, D.
    [J]. MEASUREMENT TECHNIQUES, 2016, 59 (01) : 99 - 103
  • [10] Calibration of Ultrasonic Hydrophone Probes in the Frequency Range from 250 kHz to 1 MHz
    Umchid, Sumet
    [J]. 2015 8TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2015,