Exergy Analysis of Flat Plate Solar Collectors

被引:58
|
作者
Ge, Zhong [1 ]
Wang, Huitao [1 ]
Wang, Hua [1 ]
Zhang, Songyuan [1 ]
Guan, Xin [2 ]
机构
[1] Kunming Univ Sci & Technol, Minist Educ, Engn Res Ctr Met Energy Conservat & Emiss Reduct, Kunming 650093, Peoples R China
[2] Shanghai Univ Sci & Technol, Sch Energy & Power Engn, Shanghai 200093, Peoples R China
来源
ENTROPY | 2014年 / 16卷 / 05期
关键词
flat plate collector; heat loss coefficient; exergy; exergy loss; BALANCE; ENERGY;
D O I
10.3390/e16052549
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
This study proposes the concept of the local heat loss coefficient and examines the calculation method for the average heat loss coefficient and the average absorber plate temperature. It also presents an exergy analysis model of flat plate collectors, considering non-uniformity in temperature distribution along the absorber plate. The computation results agree well with experimental data. The effects of ambient temperature, solar irradiance, fluid inlet temperature, and fluid mass flow rate on useful heat rate, useful exergy rate, and exergy loss rate are examined. An optimal fluid inlet temperature exists for obtaining the maximum useful exergy rate. The calculated optimal fluid inlet temperature is 69 degrees C, and the maximum useful exergy rate is 101.6 W. Exergy rate distribution is analyzed when ambient temperature, solar irradiance, fluid mass flow rate, and fluid inlet temperature are set to 20 degrees C, 800 W/m(2), 0.05 kg/s, and 50 degrees C, respectively. The exergy efficiency is 5.96%, and the largest exergy loss is caused by the temperature difference between the absorber plate surface and the sun, accounting for 72.86% of the total exergy rate.
引用
收藏
页码:2549 / 2567
页数:19
相关论文
共 50 条
  • [21] Entransy analysis on the thermal performance of flat plate solar air collectors
    Jie Deng
    Xudong Yang
    Yupeng Xu
    Ming Yang
    [J]. Building Simulation, 2017, 10 : 193 - 202
  • [22] Analysis of exergic efficiency formation in flat-plate solar collectors
    Avezov, R.R.
    [J]. Applied Solar Energy (English translation of Geliotekhnika), 2002, 38 (02): : 49 - 54
  • [23] TRANSIENT PLATE TEMPERATURE IN FLAT PLATE SOLAR COLLECTORS.
    Nayak, J.K.
    Goyal, I.C.
    Kaushik, S.C.
    Malik, M.A.S.
    [J]. Indian Journal of Pure and Applied Physics, 1979, 17 (12): : 851 - 853
  • [24] Experimental Study and Exergy Analysis About the Flat Plate Solar Collector
    Kareem, Fadhil Abdulrazzaq
    Skheal, Osamah Raad
    Lafta, Noor Samir
    [J]. INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2022, 14 (06): : 156 - 171
  • [25] Entransy analysis on the thermal performance of flat plate solar air collectors
    Deng, Jie
    Yang, Xudong
    Xu, Yupeng
    Yang, Ming
    [J]. BUILDING SIMULATION, 2017, 10 (02) : 193 - 202
  • [26] TRANSIENT PLATE TEMPERATURE IN FLAT-PLATE SOLAR COLLECTORS
    NAYAK, JK
    GOYAL, IC
    KAUSHIK, SC
    MALIK, MAS
    [J]. INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1979, 17 (12) : 851 - 853
  • [27] SELECTIVE FLAT-PLATE COLLECTORS FOR SOLAR DRYERS
    BOSE, ASC
    OJHA, TP
    RATNAM, VV
    DHINDAW, BK
    [J]. DRYING TECHNOLOGY, 1983, 1 (02) : 215 - 228
  • [28] Exergetic optimization research of flat plate solar collectors
    Ge, Zhong
    Wang, Huitao
    Wang, Hua
    Zhang, Songyuan
    Guan, Xin
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2015, 36 (07): : 1684 - 1689
  • [29] PARAMETRIC STUDY OF FLAT-PLATE SOLAR COLLECTORS
    TEST, FL
    [J]. ENERGY CONVERSION, 1976, 16 (1-2): : 23 - 33
  • [30] Performance of evacuated flat plate solar thermal collectors
    Moss, Roger
    Shire, Stan
    Henshall, Paul
    Arya, Farid
    Eames, Philip
    Hyde, Trevor
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 8 : 296 - 306