Variations in end-expiratory pressure during partial liquid ventilation - Impact on gas exchange, lung compliance, and end-expiratory lung volume

被引:14
|
作者
Manaligod, JM
Bendel-Stenzel, EM
Meyers, PA
Bing, DR
Connett, JE
Mammel, MC
机构
[1] Childrens Hosp & Clin, St Paul, MN USA
[2] Univ Minnesota, Dept Pediat, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Dept Biostat, Minneapolis, MN 55455 USA
关键词
lung compliance; lung injury; perfluorocarbon; positive end-expiratory pressure; ventilation;
D O I
10.1378/chest.117.1.184
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objectives: To determine the effects of different levels of positive end expiratory pressure (PEEP) during partial liquid ventilation (PLV) on gas exchange, lung compliance, and end-expiratory lung volume (EELV). Design: Prospective animal study. Setting: Animal physiology research laboratory. Subjects: Nine piglets. Interventions: Animals underwent saline solution lavage to produce lung injury. Perflubron was instilled via the endotracheal tube in a ovolume estimated to represent functional residual capacity. The initial PEEP setting was 4 cm H2O and stepwise changes in PEEP were made, At 30-min intervals, the PEEP was increased to a, then 12, then decreased back down to 8, then 4 cm H2O. Measurements and results: After 30 min at each level of PEEP, arterial blood eases, aortic and central venous pressures, heart rates, dynamic lung compliance, and changes in EELV were recorded. Paired t tests with Bonferroni correction were used to evaluate the data. There were no differences in heart rate or mean BP at the different PEEP levels. CO, elimination and oxygenation improved directly with the PEEP level and mean airway pressure (Paw). Compliance did not change with increasing PEEP, but did increase when PEEP nas lowered. EELV changes correlated directly with the level of PEEP. Conclusions: As previously reported during gas ventilation, oxygenation and CO, elimination vary directly with PEEP and proximal Paw during PLV. EELV also varies directly, with PEEP. Dynamic lung compliance, however, improved only when PEEP was lowered, suggesting an alteration in the distribution of perflubron due to changes in pressure-volume relationships.
引用
收藏
页码:184 / 190
页数:7
相关论文
共 50 条
  • [21] REGULATION OF END-EXPIRATORY LUNG-VOLUME DURING EXERCISE
    HENKE, KG
    SHARRATT, M
    PEGELOW, D
    DEMPSEY, JA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (01) : 135 - 146
  • [22] REGULATION OF END-EXPIRATORY LUNG-VOLUME DURING EXERCISE
    HENKE, KG
    SHARRATT, M
    PEGELOW, D
    DEMPSEY, J
    [J]. FEDERATION PROCEEDINGS, 1987, 46 (03) : 491 - 491
  • [23] Erratum to: End-expiratory lung volume during mechanical ventilation: a comparison with reference values and the effect of positive end-expiratory pressure in intensive care unit patients with different lung conditions
    Ido G Bikker
    Jasper van Bommel
    Dinis Reis Miranda
    Jan Bakker
    Diederik Gommers
    [J]. Critical Care, 13
  • [24] Searching for the optimal positive end-expiratory pressure for lung protective ventilation
    Sahetya, Sarina K.
    [J]. CURRENT OPINION IN CRITICAL CARE, 2020, 26 (01) : 53 - 58
  • [25] Positive end-expiratory pressure-induced changes in end-expiratory lung volume measured by spirometry and electric impedance tomography
    Grivans, C.
    Lundin, S.
    Stenqvist, O.
    Lindgren, S.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (09) : 1068 - 1077
  • [26] EXPIRATORY FLOW LIMITATION AND REGULATION OF END-EXPIRATORY LUNG-VOLUME DURING EXERCISE
    PELLEGRINO, R
    BRUSASCO, V
    RODARTE, JR
    BABB, TG
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (05) : 2552 - 2558
  • [27] Variability of End-Expiratory Lung Volume in Premature Infants
    Emeriaud, Guillaume
    Baconnier, Pierre
    Eberhard, Andre
    Debillon, Thierry
    Calabrese, Pascale
    Benchetrit, Gila
    [J]. NEONATOLOGY, 2010, 98 (04) : 321 - 329
  • [28] Heterogeneity in ventilation during positive end-expiratory pressure
    Mukesh Tripathi
    Mamta Pandey
    [J]. Critical Care, 14 (4):
  • [29] Intraoperative compliance profiles and regional lung ventilation improve with increasing positive end-expiratory pressure
    Wirth, S.
    Kreysing, M.
    Spaeth, J.
    Schumann, S.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2016, 60 (09) : 1241 - 1250
  • [30] Set positive end-expiratory pressure during protective ventilation affects lung injury
    Takeuchi, M
    Goddon, S
    Dolhnikoff, M
    Shimaoka, M
    Hess, D
    Amato, MBP
    Kacmarek, RM
    [J]. ANESTHESIOLOGY, 2002, 97 (03) : 682 - 692