Chromatic aberration correction of the human eye for retinal imaging in the near infrared

被引:61
|
作者
Fernandez, Enrique J. [1 ]
Unterhuber, Angelika
Povazay, Boris
Hermann, Boris
Artal, Pablo
Drexler, Wolfgang
机构
[1] Med Univ Vienna, Ctr Biomed Engn & Phys, Vienna, Austria
[2] Univ Murcia, Dept Fis, Lab Opt, E-30071 Murcia, Spain
关键词
D O I
10.1364/OE.14.006213
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An achromatizing lens has been designed for the human eye in the near infrared range, from 700 to 900 nm, for retinal imaging purposes. Analysis of the performance of the lens, including tolerance to misalignments, has been mathematically accomplished by using an existing eye model. The calculations have shown a virtually perfect correction of the ocular longitudinal chromatic aberration, while still keeping a high optical quality. Ocular aberrations in five subjects have been measured with and without the achromatizing lens by using a Hartmann-Shack wavefront sensor and a broad bandwidth femtosecond Ti:sapphire laser in the spectral range of interest with a set of interference filters, studying the benefits and limits in the use of the achromatizing lens. Ocular longitudinal chromatic aberration has been experimentally demonstrated to be fully corrected by the proposed lens, with no induction of any other parasitic aberration. The practical implementation of the achromatizing lens for Ophthalmoscopy, specifically for optical coherence tomography where the use of polychromatic light sources in the near infrared portion of the spectrum is mandatory, has been considered. The potential benefits of using this lens in combination with adaptive optics to achieve a full aberration correction of the human eye for retinal imaging have also been discussed.
引用
收藏
页码:6213 / 6225
页数:13
相关论文
共 50 条
  • [41] Joint Chromatic Aberration correction and Demosaicking
    Singh, Mritunjay
    Singh, Tripurari
    DIGITAL PHOTOGRAPHY VIII, 2012, 8299
  • [42] Teaching optics - On correction of chromatic aberration
    Masajada, J
    Nowak, J
    Zajac, M
    OPTICA APPLICATA, 1999, 29 (04) : 619 - 631
  • [43] Correction of chromatic aberration in hybrid objectives
    Zajac, M
    Nowak, J
    OPTIK, 2002, 113 (07): : 299 - 302
  • [44] THE CHROMATIC EYE - A NEW REDUCED-EYE MODEL OF OCULAR CHROMATIC ABERRATION IN HUMANS
    THIBOS, LN
    YE, M
    ZHANG, XX
    BRADLEY, A
    APPLIED OPTICS, 1992, 31 (19) : 3594 - 3600
  • [45] Optimizing near-infrared polariscopic imaging for the living human eye
    Jarecki, Quinn
    Kupinski, Meredith
    OPTICS EXPRESS, 2024, 32 (10): : 18113 - 18126
  • [46] Digital aberration correction for in-vivo retinal OCT imaging
    Leitgeb, Rainer A.
    Ginner, Laurin
    Kumar, Abhishek
    Fechtig, Daniel
    2016 15TH WORKSHOP ON INFORMATION OPTICS (WIO), 2016,
  • [47] TEST OF CORRECTION DEVICE FOR CHROMATIC ABERRATION AND SPHERICAL-ABERRATION
    KUCK, G
    MIKROSKOPIE, 1978, 34 (5-6) : 181 - 182
  • [49] Chromatic contrast sensitivity without correction for chromatic aberration.
    Valberg, A
    Fosse, P
    Gjerde, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4173 - 4173
  • [50] Aberration correction technology based on chromatic aberration prior constraints
    Zhang Jin-gang
    Xiang Li-bin
    Wen De-sheng
    Wang Shu-zhen
    CHINESE OPTICS, 2018, 11 (04): : 560 - 567