Virtual Single-Source Computed Tomography Using Dual-Source Acquisition A New Technique for the Dose-Neutral Intraindividual Comparison of Different Scan Protocols

被引:0
|
作者
Werncke, Thomas [1 ]
Meyer, Bernhard Christian [1 ]
Wacker, Frank K. [1 ]
von Falck, Christian [1 ]
机构
[1] Hannover Med Sch, Inst Diagnost & Intervent Radiol, D-30625 Hannover, Germany
关键词
dual source; computed tomography; phantom study; abdominal; radiation dose; virtual single-source CT; ITERATIVE RECONSTRUCTION TECHNIQUE; MODERN DIAGNOSTIC MDCT; NOISE POWER SPECTRUM; RADIATION-EXPOSURE; CANCER-RISKS; CT; REDUCTION; PERFORMANCE; VALIDATION; STANDARD;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The objective of this study was to compare the image quality of a standard single-source (SSS) computed tomography (CT) with that of a virtual single-source CT (VSS-CT) data set reconstructed from 2 raw data sets obtained by dual-source CT acquisition in abdominal CT to establish a radiation dose-neutral approach for the intraindividual comparison of 3 acquisition protocols at different radiation dose levels (RDLs). Materials and Methods: An abdominal phantom representing an 80-kg male was imaged using dual-source CT (SOMATOM Definition; Siemens Healthcare) at 3 RDLs with 120 kV(p) and different tube currents (low, standard, and high milliampere-second protocol). For each RDL, raw data were obtained once in single-source mode using x-ray tube A only and 5 times in dual-source mode using different ratios for tube current of x-ray tubes A and B (same total radiation dose; A/B: 90%/10%, 80%/20%, 70%/30%, 60%/40%, 50%/50%). For each RDL, SSS-CT and 5 virtual single-source image data sets (VSS-CT50-90) were reconstructed. To compare SSS-CT and VSS-CT data sets, image quality was assessed in terms of high- and low-contrast performance by calculating the modulation transfer function, image noise, noise power spectrum, and, for low contrast lesion detectability, the modified multiscale structural similarity index (MS-SSIM*). A maximum decrease of Delta = 5% of image quality compared with SSS-CT was defined as acceptable, and a noninferiority analysis with Delta was performed. Results: For modulation transfer function, noninferiority was observed for all VSS-CT data sets and RDL (P < 0.05). Image noise demonstrated an acceptable increase (<3.2%, P < 0.05) for each RDL and noise power spectrum showed only minor differences in the midfrequency range. The MS-SSIM* index demonstrated for the high RDL protocol a minor decrease for VSS-CT data sets (<2%, P < 0.05). For the standard and low RDL, the relative differences of the MS-SSIM* index increased and were only in 1 case above Delta (standard RDL, mean VSS-CT80 5.1%, P > 0.05). Conclusions: The image quality obtained by virtual and SSS reconstruction using equivalent total radiation exposure to the patient showed only negligible differences in image quality. Therefore, this technique might allow an intraindividual comparison of full and reduced radiation dose protocols within 1 image acquisition step by simply splitting the radiation dose between the 2 x-ray tubes of a dual-source CT.
引用
收藏
页码:742 / 748
页数:7
相关论文
共 50 条
  • [1] Image Quality Performance of Virtual Single-Source CT Using Dual-Source Computed Tomography
    Alikhani, Babak
    Werner, Martin
    Jamali, Leila
    Wacker, Frank
    Werncke, Thomas
    [J]. ACADEMIC RADIOLOGY, 2019, 26 (08) : 1095 - 1101
  • [2] Estimated radiation dose and image quality comparison of the scan protocols in dual-source computed tomography coronary angiography
    Karaarslan, Ercan
    Ulus, Sila
    Bavbek, Cengiz
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (04) : 407 - 414
  • [3] Dual-source computed tomography protocols for the pediatric chest - scan optimization techniques
    Rapp, Jordan B.
    Ho-Fung, Victor M.
    Ramirez, Karen, I
    White, Ammie M.
    Otero, Hansel J.
    Biko, David M.
    [J]. PEDIATRIC RADIOLOGY, 2023, 53 (07) : 1248 - 1259
  • [4] Dual-source computed tomography protocols for the pediatric chest — scan optimization techniques
    Jordan B. Rapp
    Victor M. Ho-Fung
    Karen I. Ramirez
    Ammie M. White
    Hansel J. Otero
    David M. Biko
    [J]. Pediatric Radiology, 2023, 53 : 1248 - 1259
  • [5] Radiation dose and image quality of computed tomography of the supra-aortic arteries: A comparison between single-source and dual-source CT Scanners
    Saba, Luca
    di Martino, Michele
    Siotto, Paolo
    Anzidei, Michele
    Argiolas, Giovanni Maria
    Porcu, Michele
    Suri, Jasjit S.
    Wintermark, Max
    [J]. JOURNAL OF NEURORADIOLOGY, 2018, 45 (02) : 136 - 141
  • [6] Dose Reduction in Abdominal Computed Tomography Intraindividual Comparison of Image Quality of Full-Dose Standard and Half-Dose Iterative Reconstructions With Dual-Source Computed Tomography
    May, Matthias S.
    Wuest, Wolfgang
    Brand, Michael
    Stahl, Christian
    Allmendinger, Thomas
    Schmidt, Bernhard
    Uder, Michael
    Lell, Michael M.
    [J]. INVESTIGATIVE RADIOLOGY, 2011, 46 (07) : 465 - 470
  • [7] Estimation and comparison of the radiation effective dose during coronary computed tomography angiography examinations on single-source 64-MDCT and dual-source 128-MDCT
    Khoramian, Daryoush
    Sistani, Soroush
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2017, 37 (04) : 826 - 836
  • [8] Dual-Source Parallel RF Transmission for Clinical MR Imaging of the Spine at 3.0 T: Intraindividual Comparison with Conventional Single-Source Transmission
    Nelles, Michael
    Koenig, Roy S.
    Gieseke, Juergen
    Guerand-van Battum, Marjolijn M.
    Kukuk, Guido M.
    Schild, Hans H.
    Willinek, Winfried A.
    [J]. RADIOLOGY, 2010, 257 (03) : 743 - 753
  • [9] Image quality and absorbed dose comparison of single- and dual-source cone-beam computed tomography
    Miura, Hideharu
    Ozawa, Shuichi
    Okazue, Toshiya
    Kawakubo, Atsushi
    Yamada, Kiyoshi
    Nagata, Yasushi
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (03): : 360 - 366
  • [10] Radiation Dose of Enhanced Dual-Source Computed Tomography Chest Scan in Congenital Heart Disease Children
    Hou, Z. H.
    Lv, B.
    Tang, X.
    Han, L.
    Jiang, S. L.
    [J]. CARDIOLOGY, 2010, 117 : 110 - 110