Photoelastic Stress Distribution Produced by Different Retention Systems for a Single-Implant Mandibular Overdenture

被引:8
|
作者
Machado Nascimento, Joao Francisco [1 ]
Aguiar-Junior, Fabio Afranio [2 ]
Nogueira, Tulio Eduardo [1 ]
Silveira Rodrigues, Renata Cristina [2 ]
Leles, Claudio Rodrigues [1 ]
机构
[1] Univ Fed Goias, Sch Dent, Dept Prevent & Oral Rehabil, BR-74605220 Goiania, Go, Brazil
[2] Univ Sao Paulo, Ribeirao Preto Sch Dent, Dept Dent Mat & Prosthodont, BR-14049 Ribeirao Preto, Brazil
关键词
Stress distribution; overdenture; implant; LOAD-TRANSFER; STANDARD; CARE; SATISFACTION; ANCHORAGE; DENTURE; NUMBER; TRIAL;
D O I
10.1111/jopr.12269
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: For patients poorly adapted to conventional dentures, the single-implant mandibular overdenture has been proposed as a simplified alternative for the two-implant treatment, together with the use of immediate loading of the implant. The aim of this in vitro study was to compare the photoelastic characteristics of stress transfer around the implant in a single-implant mandibular overdenture using different types of attachments. Materials and Methods: A photoelastic model of an edentulous mandible with a resilient edentulous ridge and a unique implant located at the symphyseal region was obtained to reproduce a single implant-retained mandibular overdenture. Six 2.0 mm height attachments were selected and inserted in the same photoelastic model in a random order. A universal testing machine was used to induce axial vertical loads of 70 Ncm applied at the central incisor and at the central region of the first right molar without contact on the contralateral side. The photoelastic analysis was performed using a polariscope integrated into the testing machine. Standard separate views were photographed, using only one model per system. A visual qualitative analysis of stress-induced fringes was performed to comparatively rank the different attachment systems. Results: All attachments showed a similar tension distribution concentrated in the apical third, and the highest stress concentration was at the apical level. There was a low stress concentration at the coronal third of the implant, with no discernible stress in the first threads of the implants, except for Dalla Bona, which showed low stress at the coronal part of the implant (1 fringe). No identifiable fringes were observed when the load was applied in the molar region, which resulted from the low amount of stress transmitted by the implant for all attachments. Conclusion: The load transferred to a single mandibular implant was evenly distributed around the implant with low stress concentration, irrespective of the type of retention system.
引用
收藏
页码:538 / 542
页数:5
相关论文
共 50 条
  • [41] Influence of Denture Cleansers on the Retention Loss of Attachment Systems Retained Implant Overdenture
    AlRumaih, Hamad S. S.
    Albarrak, Alhanouf A. A.
    AlMedaires, Muneera
    Alsulaiman, Ahmed A. A.
    Baba, Nadim Z. Z.
    Alshahrani, Faris A. A.
    Alqarawi, Firas K. K.
    Al-Dulaijan, Yousif A. A.
    Alzoubi, Fawaz
    Alhumaidan, Abdulkareem A. A.
    Gad, Mohammed M. M.
    [J]. INTERNATIONAL JOURNAL OF BIOMATERIALS, 2023, 2023
  • [43] Effect of implant angulation and patrice on the retention of overdenture attachment systems: An in vitro study
    Frantz, Kristen
    Funkenbusch, Paul
    Feng, Changyong
    Tsigarida, Alexandra
    Chochlidakis, Konstantinos
    Lo Russo, Lucio
    Ercoli, Carlo
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (05): : 452 - 459
  • [44] Use of a single implant to retain mandibular overdenture: A preliminary clinical trial of 13 cases
    Cheng, Tao
    Ma, Li
    Liu, Xi Ling
    Sun, Gui Feng
    He, Xiao Ji
    Huo, Jing Yu
    Wang, Yi Ning
    [J]. JOURNAL OF DENTAL SCIENCES, 2012, 7 (03) : 261 - 266
  • [45] METAL-REINFORCED SINGLE IMPLANT MANDIBULAR OVERDENTURE RETAINED BY AN ATTACHMENT: A CLINICAL REPORT
    Grageda, Edgar
    Rieck, Bastian
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (01): : 16 - 19
  • [46] Stress distribution of single-implant-retained overdenture reinforced with a framework: A finite element analysis study
    Amaral, Camilla F.
    Gomes, Rafael S.
    Rodrigues Garcia, Renata C. M.
    Del Bel Cury, Altair A.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (05): : 791 - 796
  • [47] Retention and wear behaviors of two implant overdenture stud-type attachments at different implant angulations
    Choi, Jae-Won
    Bae, Ji-Hyeon
    Jeong, Chang-Mo
    Huh, Jung-Bo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (05): : 628 - 635
  • [48] Evaluation of the retention characteristics of various stud attachment systems for implant retained overdenture
    Gonuldas, Fehmi
    Tokar, Emre
    Ozturk, Caner
    [J]. ACTA OF BIOENGINEERING AND BIOMECHANICS, 2018, 20 (04) : 135 - 141
  • [49] Photoelastic stress analysis of different thread designs of implant.
    Verayannont, P
    Namano, S
    Yongchareon, V
    [J]. JOURNAL OF DENTAL RESEARCH, 2003, 82 : 666 - 666
  • [50] Z LIMITED EVIDENCE SUGGESTS A SINGLE IMPLANT OVERDENTURE AS AN ALTERNATIVE TO TWO-IMPLANT-SUPPORTED MANDIBULAR OVERDENTURES
    Alqutaibi, Ahmed Yaseen
    [J]. JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2016, 16 (01) : 44 - 46