Risk Factors for Mortality in Patients With Cardiac Device-Related Infection

被引:100
|
作者
Baman, Timir S. [1 ]
Gupta, Sanjaya K. [1 ]
Valle, Javier A. [1 ]
Yamada, Elina [1 ]
机构
[1] Univ Michigan, Dept Cardiol, Ann Arbor, MI 48109 USA
来源
关键词
infection; risk factors; mortality; outcome assessment; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; PERMANENT PACEMAKER; HEART-FAILURE; PULMONARY-EMBOLISM; DRUG-USERS; ENDOCARDITIS; MANAGEMENT; RESYNCHRONIZATION; ECHOCARDIOGRAPHY; PREVENTION;
D O I
10.1161/CIRCEP.108.816868
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Because of the increased use of pacemakers and implantable cardioverter defibrillators, infection has become a complication with significant morbidity and mortality. Data on risk factors for mortality in patients with cardiac-device related infection are limited. We evaluated the prognostic significance of key clinical and echocardiographic variables in a large retrospective population of patients with cardiac-device related infection. Methods and Results-Two hundred ten patients with cardiac-device related infection were identified at the University of Michigan between 1995 and 2006. Data were abstracted on key clinical and echocardiographic variables, treatment strategy, and 6-month outcomes. We used multivariable Cox proportional hazards models to examine clinical and echocardiographic variables that were associated with 6-month mortality. Mean age for our study population was 63 17 years, and 72 (44%) were women. All-cause 6-month mortality was 18% (n=37). Independent variables associated with death were systemic embolization (hazard ratio 7.11; 95% CI 2.74 to 18.48), moderate or severe tricuspid regurgitation (hazard ratio 4.24; 95% CI 1.84 to 9.75), abnormal right ventricular function (hazard ratio 3.59; 95% CI 1.57 to 8.24), and abnormal renal function (hazard ratio 2.98; 95% CI 1.17 to 7.59). Size and mobility of cardiac device vegetations were not independently associated with mortality. Conclusions-We identified several clinical and echocardiographic variables that identify patients with cardiac-device related infection who are at high-risk for mortality and may benefit from more aggressive evaluation. (Circ Arrhythmia Electrophysiol. 2009;2:129-134.)
引用
收藏
页码:129 / 134
页数:6
相关论文
共 50 条
  • [21] Device-related infection associated with increased mortality risk in de novo transvenous implantable cardioverter-defibrillator medicare patients
    El-Chami, Mikhael F.
    Liu, Yiyan
    Griffiths, Robert, I
    Knight, Bradley P.
    Weiss, Raul
    Mark, George E.
    Biffi, Mauro
    Probst, Vincent
    Lambiase, Pier D.
    Miller, Marc A.
    Jacobsen, Caroline M.
    Baddour, Larry M.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (04) : 725 - 730
  • [22] Mortality predictors of device-related infective endocarditis in cardiac resynchronization therapy recipients
    Jedrzejczyk-Patej, E.
    Mazurek, M.
    Kowalski, O.
    Sokal, A.
    Koziel, M.
    Adamczyk, K.
    Przybylska-Siedlecka, K.
    Morawski, S.
    Liberska, A.
    Szulik, M.
    Podolecki, T.
    Kowalczyk, J.
    Sawicka, M.
    Kalarus, Z.
    Lenarczyk, R.
    [J]. EUROPEAN HEART JOURNAL, 2017, 38 : 1168 - 1168
  • [23] Risk Factors of the Totally Implantable Venous Access Device-Related Infection in Patients With Brain Tumors Undergoing Chemotherapy After Surgery
    Li, Haihong
    Shan, Jing
    [J]. SURGICAL INFECTIONS, 2024, 25 (02) : 133 - 139
  • [24] Breaking the Chain of Infection in Older Adults A Review of Risk Factors and Strategies for Preventing Device-Related Infections
    Schrank, Gregory
    Branch-Elliman, Westyn
    [J]. INFECTIOUS DISEASE CLINICS OF NORTH AMERICA, 2017, 31 (04) : 649 - +
  • [25] Risk factors for treatment failure in orthopedic device-related methicillin-resistant Staphylococcus aureus infection
    Ferry, T.
    Uckay, I.
    Vaudaux, P.
    Francois, P.
    Schrenzel, J.
    Harbarth, S.
    Laurent, F.
    Bernard, L.
    Vandenesch, F.
    Etienne, J.
    Hoffmeyer, P.
    Lew, D.
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2010, 29 (02) : 171 - 180
  • [26] Risk factors for treatment failure in orthopedic device-related methicillin-resistant Staphylococcus aureus infection
    T. Ferry
    I. Uçkay
    P. Vaudaux
    P. François
    J. Schrenzel
    S. Harbarth
    F. Laurent
    L. Bernard
    F. Vandenesch
    J. Etienne
    P. Hoffmeyer
    D. Lew
    [J]. European Journal of Clinical Microbiology & Infectious Diseases, 2010, 29 : 171 - 180
  • [27] TEMPORAL TRENDS IN COMORBIDITIES AND OUTCOMES OF CARDIAC DEVICE-RELATED INFECTION IN THE YOUNGER ADULTS
    Shah, Kashyap
    Modi, Vivek Amit
    Thyagaturu, Harshith
    Pandya, Maharshi
    Shirani, Jamshid
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 153 - 153
  • [28] Rare enough ? Cardiac Device-related pocket Infection due to Mycobacterium fortuitum
    Golamari, Reshma
    Sahu, Nitasa
    Vunnam, Rama
    Bhatt, Dhirisha
    Thapa, Rameet
    Patel, Ravi
    Jain, Rohit
    [J]. CLINICAL CASE REPORTS, 2021, 9 (03): : 1566 - 1570
  • [29] New guidelines for prevention and management of implantable cardiac electronic device-related infection
    Sandoe, Jonathan A. T.
    Barlow, Gavin
    Chambers, John B.
    Gammage, Michael
    Guleri, Achyut
    Howard, Philip
    Olson, Ewan
    Perry, John D.
    Prendergast, Bernard D.
    Spry, Michael J.
    Steeds, Richard P.
    Tayebjee, Muzahir H.
    Watkin, Richard
    [J]. LANCET, 2015, 385 (9984): : 2225 - 2226
  • [30] Determining the incidence and risk factors of medical device-related pressure injury in intensive care patients
    Karacabay, Kevser
    Savci, Ayseguel
    Dalkilic, Mehmet
    Hergul, Filiz Kabu
    [J]. JOURNAL OF TISSUE VIABILITY, 2023, 32 (04) : 596 - 600