Desiccant solutions, membrane technologies, and regeneration techniques in liquid desiccant air conditioning system

被引:25
|
作者
Oladosu, Temidayo Lekan [1 ]
Baheta, Aklilu Tesfamichael [1 ]
Oumer, Ahmed N. [2 ]
机构
[1] Univ Teknol PETRONAS, Dept Mech Engn, Seri Iskandar, Perak, Malaysia
[2] Univ Malaysia Pahang, Dept Mech Engn, Pekan, Pahang, Malaysia
关键词
bio‐ desiccants; energy‐ saving; ionic liquids; membranes; non‐ thermal regeneration; DEEP EUTECTIC SOLVENTS; VAPOR COMPRESSION REFRIGERATION; EVAPORATIVE COOLING SYSTEM; ION-EXCHANGE MEMBRANES; MASS-TRANSFER; PERFORMANCE ANALYSIS; LOW-TEMPERATURE; ELECTRODIALYSIS REGENERATION; DEHUMIDIFICATION SYSTEM; THERMAL REGENERATION;
D O I
10.1002/er.6482
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Liquid desiccant air dehumidification has gained substantial attention recently due to its attractive energy-saving capability, high moisture retention, and low regeneration temperature. However, there are still unresolved limitations in liquid desiccant air conditioning systems (LDACs). Among on-going studies are the search for greener desiccant solvents, high-performance membrane, and regeneration techniques hybridization. This review discusses up-to-date development of the performance influential components of LDACs, such as desiccant properties, regeneration techniques, membranes, energy sources, and hybrid system configurations. The corrosive nature of conventional halide salt solutions, non-biodegradability and high viscosity property of most ionic liquids necessitate the search for alternative solvents in LDACs. Deep eutectic solvents (DES) properties, such as non-corrosive, hygroscopic, biodegradable, and low viscosity idealize promising alternative desiccant solutions. Therefore, DES may be usefully explored and further investigated in LDACs to establish the degree of their capacities in replacing conventional desiccants. Non-thermal regeneration techniques and nanoparticle enhanced membranes were also found to improve the overall energy performance of the LDAC system. Non-thermal regeneration techniques can operate below 40 degrees C and reduce energy utilization between 10% and 50% in indoor space cooling. The coefficient of performance (COP) of this regeneration category is capable of being as high as 6, which is an indication of its promising energy-saving propensity. Highlights Review on liquid desiccant materials and the potential of deep eutectic solvents as bio-desiccants for air dehumidification. Nanoparticles enhanced ion exchange membrane tendency to eliminate membrane fouling and improve regeneration performance. Non-thermal liquid desiccant regeneration techniques eliminate re-cooling energies requirement in LDACs.
引用
收藏
页码:8420 / 8447
页数:28
相关论文
共 50 条
  • [1] Membrane Processes for the Regeneration of Liquid Desiccant Solution for Air Conditioning
    Hung Cong Duong
    Ashley Joy Ansari
    Long Duc Nghiem
    Hai Thuong Cao
    Thao Dinh Vu
    Thao Phuong Nguyen
    [J]. Current Pollution Reports, 2019, 5 : 308 - 318
  • [2] Membrane Processes for the Regeneration of Liquid Desiccant Solution for Air Conditioning
    Duong, Hung Cong
    Ansari, Ashley Joy
    Nghiem, Long Duc
    Cao, Hai Thuong
    Vu, Thao Dinh
    Nguyen, Thao Phuong
    [J]. CURRENT POLLUTION REPORTS, 2019, 5 (04) : 308 - 318
  • [3] Experimental Study on Vacuum Membrane Distillation Liquid Regeneration of Liquid Desiccant Air Conditioning System
    Zhou, Jun-Ming
    Zhang, Xiao-Song
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2020, 41 (11): : 2635 - 2640
  • [4] Liquid desiccant lithium chloride regeneration by membrane distillation for air conditioning
    Duong, Hung C.
    Hai, Faisal I.
    Al-Jubainawi, Ali
    Ma, Zhenjun
    He, Tao
    Nghiem, Long D.
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2017, 177 : 121 - 128
  • [5] Liquid desiccant regeneration for advanced air conditioning: A comprehensive review on desiccant materials, regenerators, systems and improvement technologies
    Su, Wei
    Lu, Zhifei
    She, Xiaohui
    Zhou, Junming
    Wang, Feng
    Sun, Bo
    Zhang, Xiaosong
    [J]. APPLIED ENERGY, 2022, 308
  • [6] Membrane distillation to regenerate different liquid desiccant solutions for air conditioning
    Duong, Hung C.
    Alvarez, Ivan R. C.
    Nguyen, Tinh V.
    Nghiem, Long D.
    [J]. DESALINATION, 2018, 443 : 137 - 142
  • [7] A Review of Regeneration Methods for Liquid Desiccant Air-Conditioning System
    Cheng, Qing
    Zhang, Xiaosong
    [J]. PROCEEDINGS OF THE 2013 INTERNATIONAL CONFERENCE ON MATERIAL SCIENCE AND ENVIRONMENTAL ENGINEERING (MSEE 2013), 2013, : 1 - 5
  • [8] A solar desiccant pre-treatment electrodialysis regeneration system for liquid desiccant air-conditioning system
    Cheng, Qing
    Zhang, Xiao-Song
    [J]. ENERGY AND BUILDINGS, 2013, 67 : 434 - 444
  • [9] Performance analysis of a novel multi-function liquid desiccant regeneration system for liquid desiccant air-conditioning system
    Cheng, Qing
    Xu, Wenhao
    [J]. ENERGY, 2017, 140 : 240 - 252
  • [10] Experimental comparative research on electrodialysis regeneration for liquid desiccant with different concentrations in liquid desiccant air-conditioning system
    Cheng, Qing
    Zhang, Xiaosong
    Jiao, Shun
    [J]. ENERGY AND BUILDINGS, 2017, 155 : 475 - 483