Accuracy of periocular lesion assessment using telemedicine

被引:8
|
作者
Kang, Swan [1 ]
Dehabadi, Mohammad [1 ]
Sim, Dawn A. [2 ,3 ]
Thomas, Peter B. M. [2 ,3 ]
Ewusi, Doris Appiah [1 ]
Ezra, Daniel [1 ]
机构
[1] Moorfields Eye Hosp NHS Fdn Trust, Adnexal Dept, London, England
[2] Moorfields Eye Hosp NHS Fdn Trust, NIHR Biomed Res Ctr Ophthalmol, London, England
[3] UCL, Inst Ophthalmol, London, England
关键词
information systems; health care; medical informatics; patient care; CLINICAL-DIAGNOSIS; CUTANEOUS MELANOMA; EYELID LESIONS; RISK-FACTORS; SKIN; TELEOPHTHALMOLOGY; OPHTHALMOLOGY; SENSITIVITY; MANAGEMENT; PROGRAM;
D O I
10.1136/bmjhci-2020-100287
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objectives To assess the agreement in diagnosis and management plans reached between clinicians reviewing eyelid lesions remotely and in face-to-face clinics. Methods In this single-centre observational case series, data were prospectively collected on 50 consecutive adults referred with eyelid lesions suitable to be seen by a nurse. A proforma was completed to gather salient information. A nurse specialist saw patients in face-to-face clinics and collected information using the proforma, devising a diagnosis and management plan. Photographs of the eyelid lesions were taken by a medical photographer. A subsequent remote review was completed by an oculoplastic consultant using the proforma information and photographs in the absence of the patient. The diagnosis and management plan constructed by the nurse specialist were compared with those reached by the consultant. Results Complete data were available for 44 consecutive cases. There was an overall 91% agreement (40 cases out of 44) between the diagnoses reached by the nurse specialist, and the remote reviewer; kappa coefficient 0.88 (95% CI 0.76 to 0.99). There was an overall 82% agreement (36 out of 44 cases) in the management plans devised by the nurse-led clinic and remote reviewer; kappa coefficient 0.74 (95% CI 0.58 to 0.90). The average time taken for a remote reviewer to reach a diagnosis and management plan was 1 min and 20 s. Conclusions This study evaluated the feasibility of assessing eyelid lesions using asynchronous telemedicine. There was overall a high rate of concordance in the diagnosis reached, and management devised between the clinic and remote review.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] The role of telemedicine in the assessment of strabismus
    Dawson, E
    Kennedy, C
    Bentley, C
    Lee, J
    Murdoch, I
    [J]. JOURNAL OF TELEMEDICINE AND TELECARE, 2002, 8 (01) : 52 - 55
  • [42] Automated Precancerous Lesion Screening Using an Instance Segmentation Technique for Improving Accuracy
    Agustiansyah, Patiyus
    Nurmaini, Siti
    Nuranna, Laila
    Irfannuddin, Irfannuddin
    Sanif, Rizal
    Legiran, Legiran
    Rachmatullah, Muhammad Naufal
    Florina, Gavira Olipa
    Sapitri, Ade Iriani
    Darmawahyuni, Annisa
    [J]. SENSORS, 2022, 22 (15)
  • [43] Biometric Identification Using the Periocular Region
    Kumar, K. Kishore
    Rao, P. Trinatha
    [J]. INFORMATION AND COMMUNICATION TECHNOLOGY FOR INTELLIGENT SYSTEMS (ICTIS 2017) - VOL 2, 2018, 84 : 619 - 628
  • [44] ASSESSMENT OF LESION SEVERITY USING A NOVEL LESION MOLDING CATHETER - IN-VITRO VALIDATION STUDIES
    LUNDKVIST, AJS
    MULLEN, WL
    SUDHIR, K
    YOUR, AJJ
    YOCK, PG
    [J]. CIRCULATION, 1993, 88 (04) : 650 - 650
  • [45] Artificial intelligence to automate assessment of ocular and periocular measurements
    Rana, Khizar
    Beecher, Mark
    Caltabiano, Carmelo
    Macri, Carmelo
    Zhao, Yang
    Verjans, Johan
    Selva, Dinesh
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024,
  • [46] In vivo accuracy and reliability of color-coded image enhancements for the assessment of periradicular lesion dimensions
    Scarfe, WC
    Czerniejewski, VJ
    Farman, AG
    Avant, SL
    Molteni, R
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 88 (05): : 603 - 611
  • [47] ACCURACY OF INTRACARDIAC ULTRASOUND ASSESSMENT OF RF ABLATION LESION DIMENSIONS IN THE INTACT CANINE ATRIUM AND VENTRICLE
    CHAN, RC
    JOHNSON, SB
    SEWARD, JB
    PACKER, DL
    [J]. CIRCULATION, 1995, 92 (08) : 3820 - 3820
  • [48] Accuracy versus reproducibility: comprehensive assessment of four automated methods for multiple sclerosis lesion segmentation
    Fartaria, M. J.
    Corredor-Jerez, R.
    Richiardi, J.
    Marechal, B.
    Granziera, C.
    Cuadra, M. Bach
    Tsang, A.
    Bermel, R.
    Jones, S. E.
    Izbudak, I.
    Lui, Y. W.
    Krupp, L.
    Mowry, E. M.
    Fisher, E.
    Kober, T.
    [J]. MULTIPLE SCLEROSIS JOURNAL, 2018, 24 : 359 - 359
  • [49] Propranolol and Periocular Capillary Hemangiomas: Assessment of Refractive Effect
    Glasman, Peter
    Chandna, Arvind
    Nayak, Harish
    Mangat, Simran
    Kaye, Stephen
    [J]. JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2014, 51 (03) : 165 - 170
  • [50] A NOVEL APPROACH FOR DIAGNOSING LIVER LESION IMAGES IN TELEMEDICINE MODE
    Ulagamuthalvi, V.
    Kulanthaivel, G.
    Sridharan, D.
    [J]. NITTE UNIVERSITY JOURNAL OF HEALTH SCIENCE, 2012, 2 (04): : 50 - 53