Transient radiative heating characteristics of slabs in a walking beam type reheating furnace

被引:65
|
作者
Han, Sang Heon [1 ]
Baek, Seung Wook [1 ]
Kim, Man Young [2 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Aerosp, Taejon 305701, South Korea
[2] Chonbuk Natl Univ, Sch Mech & Aerosp Syst Engn, Jeonju 561756, Chonbuk, South Korea
关键词
Reheating furnace; Radiative slab heating; Residence time; FINITE-VOLUME METHOD; NUMERICAL-ANALYSIS;
D O I
10.1016/j.ijheatmasstransfer.2008.07.030
中图分类号
O414.1 [热力学];
学科分类号
摘要
Transient radiative heating characteristics of slabs in a walking beam type reheating furnace is predicted by the finite-volume method (FVM) for radiation, The FVM can calculate the radiative intensity absorbed and emitted by hot gas as well as emitted by the wall with curvilinear geometry. The non-gray weighted sum of gray gas model (WSGGM) which is more realistic than the gray gas model is used for better accurate prediction of gas radiation. The block-off procedure is applied to the treatment of the slabs inside which intensity has no meaning. Entire domain is divided into eight sub-zones to specify temperature distribution, and each sub-zone has different temperatures and the same species composition. Temperature field of a slab is acquired by solving the transient 3D heat conduction equation. Incident radiation flux into a slab is used for the boundary condition of the heat conduction equation governing the slab temperature. The movement of the slabs is taken into account and calculation is performed during the residence time of a slab in the furnace. The slab heating characteristics is also investigated for the various slab residence times. Main interest of this study is the transient variation of the average temperature and temperature non-uniformity of the slabs. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1005 / 1011
页数:7
相关论文
共 50 条
  • [21] Optimum residence time analysis for a walking beam type reheating furnace
    Han, Sang Heon
    Chang, Daejun
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (15-16) : 4079 - 4087
  • [22] WALKING BEAM SLAB REHEATING FURNACE DESIGN
    ENK, AT
    METALLURGIA, 1970, 82 (491): : 87 - &
  • [23] FNNC Technology for Walking Beam Reheating Furnace
    Fu, Shuguang
    Zeng, Liangcai
    Chen, Kuisheng
    PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION (ICMS2009), VOL 1, 2009, : 428 - 434
  • [24] HEATING CHARACTERISTICS OF THE OPEN RADIANT TUBE TYPE REHEATING FURNACE
    MURANAKA, K
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1985, 71 : 1201 - 1201
  • [25] Optimisation of a slab heating pattern with various skid button heights in a walking-beam-type reheating furnace
    Jang, Jiin-Yuh
    Huang, Jun-Bo
    IRONMAKING & STEELMAKING, 2018, 45 (09) : 793 - 804
  • [26] Mathematical Model of the Heating Process in a Walking-Beam Billet Reheating Furnace.
    Janata, J.
    Gaswaerme International, 1985, 34 (10): : 400 - 404
  • [27] EXPERIMENTAL RESULTS OF CHARACTERISTICS FOR HEATING IN REHEATING FURNACE (DEVELOPMENT OF THE OPEN RADIANT TUBE TYPE REHEATING FURNACE - II).
    Ohtuki, Naoki
    Sasaji, Shun
    Inoue, Norio
    Matumoto, Yoshihumi
    Goto, Koichiro
    Transactions of the Iron and Steel Institute of Japan, 1983, 24 (03)
  • [28] MODELING OF STEEL SLAB REHEATING PROCESS IN A WALKING BEAM REHEATING FURNACE
    Tang, Guangwu
    Saavedra, Arturo
    Okosun, Tyamo
    Wu, Bin
    Zhou, Chenn Q.
    Bai, Dengqi
    Wang, Yufeng
    Bodnar, Rick
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2016, VOL 2, 2016,
  • [29] Numerical simulation of pressure distribution in a walking-beam type reheating furnace
    Li, Chaoxiang
    Huang, Yajun
    Sun, Junbo
    Ni, Yang
    Lu, Linlin
    FOURTH INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2020, 467
  • [30] Oxidation model of slabs in an industrial-scale walking-beam reheating furnace with mixed loading
    Xu, Jianxiang
    Li, Baokuan
    Qi, Fengsheng
    APPLIED THERMAL ENGINEERING, 2024, 256