End-expiratory lung volume during mechanical ventilation: a comparison with reference values and the effect of positive end-expiratory pressure in intensive care unit patients with different lung conditions

被引:57
|
作者
Bikker, Ido G. [1 ]
van Bommel, Jasper [1 ]
Miranda, Dinis Reis [1 ]
Bakker, Jan [1 ]
Gommers, Diederik [1 ]
机构
[1] Erasmus MC, Dept Intens Care Med, NL-3015 CE Rotterdam, Netherlands
来源
CRITICAL CARE | 2008年 / 12卷 / 06期
关键词
D O I
10.1186/cc7125
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Functional residual capacity (FRC) reference values are obtained from spontaneous breathing patients, and are measured in the sitting or standing position. During mechanical ventilation FRC is determined by the level of positive end-expiratory pressure (PEEP), and it is therefore better to speak of end-expiratory lung volume. Application of higher levels of PEEP leads to increased end-expiratory lung volume as a result of recruitment or further distention of already ventilated alveoli. The aim of this study was to measure end-expiratory lung volume in mechanically ventilated intensive care unit (ICU) patients with different types of lung pathology at different PEEP levels, and to compare them with predicted sitting FRC values, arterial oxygenation, and compliance values. Methods End-expiratory lung volume measurements were performed at PEEP levels reduced sequentially (15, 10 and then 5 cmH(2)O) in 45 mechanically ventilated patients divided into three groups according to pulmonary condition: normal lungs (group N), primary lung disorder (group P), and secondary lung disorder (group S). Results In all three groups, end-expiratory lung volume decreased significantly (P < 0.001) while PEEP decreased from 15 to 5 cmH(2)O, whereas the ratio of arterial oxygen tension to inspired oxygen fraction did not change. At 5 cmH(2)O PEEP, end-expiratory lung volume was 31, 20, and 17 ml/kg predicted body weight in groups N, P, and S, respectively. These measured values were only 66%, 42%, and 34% of the predicted sitting FRC. A correlation between change in end-expiratory lung volume and change in dynamic compliance was found in group S (P < 0.001; R-2 = 0.52), but not in the other groups. Conclusions End-expiratory lung volume measured at 5 cmH(2)O PEEP was markedly lower than predicted sitting FRC values in all groups. Only in patients with secondary lung disorders were PEEP-induced changes in end-expiratory lung volume the result of derecruitment. In combination with compliance, end-expiratory lung volume can provide additional information to optimize the ventilator settings.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [21] End-expiratory lung impedance change enables bedside monitoring of end-expiratory lung volume change
    Hinz, J
    Hahn, G
    Neumann, P
    Sydow, M
    Mohrenweiser, P
    Hellige, G
    Burchardi, H
    INTENSIVE CARE MEDICINE, 2003, 29 (01) : 37 - 43
  • [22] Optimizing lung aeration in positive end-expiratory pressure
    Rouby, JJ
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 170 (10) : 1039 - 1040
  • [23] End-expiratory lung volume and ventilation distribution with different continuous positive airway pressure systems in volunteers
    Andersson, B.
    Lundin, S.
    Lindgren, S.
    Stenqvist, O.
    Herges, H. Odenstedt
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (02) : 157 - 164
  • [24] POSITIVE END-EXPIRATORY PRESSURE IN ACUTE LUNG INJURY
    SHAPIRO, BA
    CANE, RD
    HARRISON, RA
    CHEST, 1983, 83 (03) : 558 - 563
  • [25] LUNG RUPTURE AND OCCULT POSITIVE END-EXPIRATORY PRESSURE
    STRATTON, D
    LANCET, 1976, 1 (7963): : 811 - 811
  • [26] Effects of manual chest compression on expiratory flow bias during the positive end-expiratory pressure-zero end-expiratory pressure maneuver in patients on mechanical ventilation
    Otoni Oliveira, Ana Carolina
    Lorena, Daiane Menezes
    Gomes, Livia Correa
    Reges Amaral, Bianca Lorrane
    Volpe, Marcia Souza
    JORNAL BRASILEIRO DE PNEUMOLOGIA, 2019, 45 (03)
  • [27] Set positive end-expiratory pressure during protective ventilation affects lung injury
    Takeuchi, M
    Goddon, S
    Dolhnikoff, M
    Shimaoka, M
    Hess, D
    Amato, MBP
    Kacmarek, RM
    ANESTHESIOLOGY, 2002, 97 (03) : 682 - 692
  • [28] MECHANICS OF VENTILATION WITH POSITIVE END-EXPIRATORY PRESSURE
    HOBELMANN, CF
    SMITH, DE
    VIRGILIO, RW
    PETERS, RM
    ANNALS OF THORACIC SURGERY, 1977, 24 (01): : 68 - 76
  • [29] Positive end-expiratory pressure-induced changes in end-expiratory lung volume measured by spirometry and electric impedance tomography
    Grivans, C.
    Lundin, S.
    Stenqvist, O.
    Lindgren, S.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (09) : 1068 - 1077
  • [30] Measurement of the end-expiratory lung volume without interruption of mechanical ventilation in pediatric patients
    IG Bikker
    T Scohy
    D Gommers
    Critical Care, 13 (Suppl 1):