End-expiratory lung volume during mechanical ventilation: a comparison with reference values and the effect of positive end-expiratory pressure in intensive care unit patients with different lung conditions

被引:57
|
作者
Bikker, Ido G. [1 ]
van Bommel, Jasper [1 ]
Miranda, Dinis Reis [1 ]
Bakker, Jan [1 ]
Gommers, Diederik [1 ]
机构
[1] Erasmus MC, Dept Intens Care Med, NL-3015 CE Rotterdam, Netherlands
来源
CRITICAL CARE | 2008年 / 12卷 / 06期
关键词
D O I
10.1186/cc7125
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Functional residual capacity (FRC) reference values are obtained from spontaneous breathing patients, and are measured in the sitting or standing position. During mechanical ventilation FRC is determined by the level of positive end-expiratory pressure (PEEP), and it is therefore better to speak of end-expiratory lung volume. Application of higher levels of PEEP leads to increased end-expiratory lung volume as a result of recruitment or further distention of already ventilated alveoli. The aim of this study was to measure end-expiratory lung volume in mechanically ventilated intensive care unit (ICU) patients with different types of lung pathology at different PEEP levels, and to compare them with predicted sitting FRC values, arterial oxygenation, and compliance values. Methods End-expiratory lung volume measurements were performed at PEEP levels reduced sequentially (15, 10 and then 5 cmH(2)O) in 45 mechanically ventilated patients divided into three groups according to pulmonary condition: normal lungs (group N), primary lung disorder (group P), and secondary lung disorder (group S). Results In all three groups, end-expiratory lung volume decreased significantly (P < 0.001) while PEEP decreased from 15 to 5 cmH(2)O, whereas the ratio of arterial oxygen tension to inspired oxygen fraction did not change. At 5 cmH(2)O PEEP, end-expiratory lung volume was 31, 20, and 17 ml/kg predicted body weight in groups N, P, and S, respectively. These measured values were only 66%, 42%, and 34% of the predicted sitting FRC. A correlation between change in end-expiratory lung volume and change in dynamic compliance was found in group S (P < 0.001; R-2 = 0.52), but not in the other groups. Conclusions End-expiratory lung volume measured at 5 cmH(2)O PEEP was markedly lower than predicted sitting FRC values in all groups. Only in patients with secondary lung disorders were PEEP-induced changes in end-expiratory lung volume the result of derecruitment. In combination with compliance, end-expiratory lung volume can provide additional information to optimize the ventilator settings.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [1] End-expiratory lung volume during mechanical ventilation: a comparison with reference values and the effect of positive end-expiratory pressure in intensive care unit patients with different lung conditions
    Ido G Bikker
    Jasper van Bommel
    Dinis Reis Miranda
    Jan Bakker
    Diederik Gommers
    Critical Care, 12
  • [2] Erratum to: End-expiratory lung volume during mechanical ventilation: a comparison with reference values and the effect of positive end-expiratory pressure in intensive care unit patients with different lung conditions
    Ido G Bikker
    Jasper van Bommel
    Dinis Reis Miranda
    Jan Bakker
    Diederik Gommers
    Critical Care, 13
  • [3] End-expiratory lung volume during mechanical ventilation: a comparison with reference values and the effect of positive end-expiratory pressure in intensive care unit patients with different lung conditions (vol 12, pg R145, 2008)
    Bikker, Ido G.
    van Bommel, Jasper
    Miranda, Dinis Reis
    Bakker, Jan
    Gommers, Diederik
    CRITICAL CARE, 2009, 13 (06):
  • [4] Positive end-expiratory pressure improves end-expiratory lung volume but not oxygenation after induction of anaesthesia
    Futier, Emmanuel
    Constantin, Jean-Michel
    Petit, Antoine
    Jung, Boris
    Kwiatkowski, Fabrice
    Duclos, Martine
    Jaber, Samir
    Bazin, Jean-Etienne
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (06) : 508 - 513
  • [5] Variations in end-expiratory pressure during partial liquid ventilation - Impact on gas exchange, lung compliance, and end-expiratory lung volume
    Manaligod, JM
    Bendel-Stenzel, EM
    Meyers, PA
    Bing, DR
    Connett, JE
    Mammel, MC
    CHEST, 2000, 117 (01) : 184 - 190
  • [6] Positive end-expiratory pressure individualization guided by continuous end-expiratory lung volume monitoring during laparoscopic surgery
    Gerardo Tusman
    Mats Wallin
    Cecilia Acosta
    Bruno Santanera
    Facundo Portela
    Federico Viotti
    Nora Fuentes
    Magnus Hallbäck
    Fernando Suarez-Sipmann
    Journal of Clinical Monitoring and Computing, 2022, 36 : 1557 - 1567
  • [7] Positive end-expiratory pressure individualization guided by continuous end-expiratory lung volume monitoring during laparoscopic surgery
    Tusman, Gerardo
    Wallin, Mats
    Acosta, Cecilia
    Santanera, Bruno
    Portela, Facundo
    Viotti, Federico
    Fuentes, Nora
    Hallback, Magnus
    Suarez-Sipmann, Fernando
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (05) : 1557 - 1567
  • [8] Positive end-expiratory pressure in the pediatric intensive care unit
    Kneyber, Martin C. J.
    PAEDIATRIC RESPIRATORY REVIEWS, 2024, 49 : 5 - 8
  • [9] INADVERTENT POSITIVE END-EXPIRATORY PRESSURE DURING MECHANICAL VENTILATION
    BANCALARI, E
    JOURNAL OF PEDIATRICS, 1986, 108 (04): : 567 - 569
  • [10] EFFECT OF TIDAL VOLUME AND POSITIVE END-EXPIRATORY PRESSURE ON COMPLIANCE DURING MECHANICAL VENTILATION
    SUTER, PM
    FAIRLEY, HB
    ISENBERG, MD
    CHEST, 1978, 73 (02) : 158 - 162