Implementation of an iterative scatter correction, the influence of attenuation map quality and their effect on absolute quantitation in SPECT

被引:43
|
作者
Vandervoort, Eric
Celler, Anna
Harrop, Ronald
机构
[1] Univ British Columbia, Dept Phys & Astron, Vancouver, BC V6T 1Z1, Canada
[2] Univ British Columbia, Dept Radiol, Vancouver, BC V5Z 1L8, Canada
[3] Simon Fraser Univ, Sch Comp Sci, Burnaby, BC V5A 1S6, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 05期
关键词
D O I
10.1088/0031-9155/52/5/020
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We investigated the accuracy of qSPECT, a quantitative SPECT reconstruction algorithm we have developed which employs corrections for collimator blurring, photon attenuation and scatter, and provides images in units of absolute radiotracer concentrations (kBq cm(-3)). Using simulated and experimental phantom data with characteristics similar to clinical cardiac perfusion data, we studied the implementation of a scatter correction (SC) as part of an iterative reconstruction protocol. Additionally, with experimental phantom studies we examined the influence of CT-based attenuation maps, relative to those obtained from conventional SPECT transmission scans, on SCs and quantitation. Our results indicate that the qSPECT estimated scatter corrections did not change appreciably after the third iteration of the reconstruction. For the simulated data, qSPECT concentrations agreed with images reconstructed using ideal, scatter-free, simulated data to within 6%. For the experimental data, we observed small systematic differences in the scatter fractions for data using different combinations of SCs and attenuation maps. The SCs were found to be significantly influenced by errors in image coregistration. The reconstructed concentrations using CT-based corrections were more quantitatively accurate than those using attenuation maps from conventional SPECT transmission scans. However, segmenting the attenuation maps from SPECT transmission scans could provide sufficient accuracy for most applications.
引用
收藏
页码:1527 / 1545
页数:19
相关论文
共 50 条
  • [1] The influence of attenuation-map quality on the absolute quantitative accuracy of SPECT images
    Vandervoort, E
    Celler, A
    Wells, G
    Blinder, S
    Dixon, K
    Pang, YX
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2700 - 2704
  • [2] Impact of the attenuation map on relative and absolute quantitation in brain SPECT.
    El Fakhri, G
    Moore, SC
    Kijewski, MF
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 61P - 62P
  • [3] IMPROVEMENT OF QUANTITATION IN SPECT - ATTENUATION AND SCATTER CORRECTION USING NON-UNIFORM ATTENUATION DATA
    MUKAI, T
    TORIZUKA, K
    DOUGLASS, KH
    WAGNER, HN
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (05) : P91 - P91
  • [4] Attenuation correction in SPECT without attenuation map
    Kacperski, Krzysztof
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3820 - 3822
  • [5] ATTENUATION AND SCATTER CORRECTION AIMING AT QUANTITATIVE SPECT
    AXELSSON, B
    ISRAELSSON, A
    LARSSON, SA
    MSAKI, P
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1984, 9 (07): : A83 - A83
  • [6] DEVELOPMENT OF AN ITERATIVE SCATTER CORRECTION TECHNIQUE FOR SPECT
    BAILEY, DL
    HUTTON, BF
    MEIKLE, SR
    FULTON, RR
    JACKSON, CB
    [J]. AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1988, 18 (03): : 501 - 501
  • [7] Attenuation compensation and Compton scatter correction: Improvement in brain SPECT image quality
    Naimi, A
    Papazyan, J
    Allaoua, M
    Buchegger, F
    Slosman, DO
    [J]. RADIOLOGY, 1996, 201 : 1486 - 1486
  • [8] Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT
    Koichi Okuda
    Kenichi Nakajima
    Masato Yamada
    Hiroshi Wakabayashi
    Hajime Ichikawa
    Hiroyuki Arai
    Shinro Matsuo
    Junichi Taki
    Mitsumasa Hashimoto
    Seigo Kinuya
    [J]. Annals of Nuclear Medicine, 2014, 28 : 60 - 68
  • [9] Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT
    Okuda, Koichi
    Nakajima, Kenichi
    Yamada, Masato
    Wakabayashi, Hiroshi
    Ichikawa, Hajime
    Arai, Hiroyuki
    Matsuo, Shinro
    Taki, Junichi
    Hashimoto, Mitsumasa
    Kinuya, Seigo
    [J]. ANNALS OF NUCLEAR MEDICINE, 2014, 28 (01) : 60 - 68
  • [10] NON-UNIFORM ATTENUATION AND SCATTER CORRECTION IN SPECT
    SINGH, M
    HORNE, M
    MANEVAL, D
    AMARTEY, J
    BRECHNER, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 767 - 771