Influence of ceramic thickness and type on micromechanical properties of light-cured adhesive bonding agents

被引:7
|
作者
Ozturk, Elif [1 ]
Bolay, Sukran [1 ]
Hickel, Reinhard [2 ]
Ilie, Nicoleta [2 ]
机构
[1] Hacettepe Univ, Fac Dent, Dept Restorat Dent, TR-06100 Ankara, Turkey
[2] Univ Munich, Sch Dent, Dept Restorat Dent, Munich, Germany
关键词
adhesive bonding agents; ceramic veneers; hardness; indentation modulus; micromechanical properties; MECHANICAL-PROPERTIES; POLYMERIZATION EFFICIENCY; PHYSICAL-PROPERTIES; DENTAL ADHESIVES; RESIN; STRENGTH; TRANSLUCENCY; VENEERS; SHEAR;
D O I
10.3109/00016357.2013.876661
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The aim of this study was to evaluate the micromechanical properties of different adhesive bonding agents when polymerized through ceramics. Materials and methods. Sixty sound extracted human third molars were selected and the crowns were sectioned perpendicular to the long axis in order to obtain dentin slices to be bonded with one of the following adhesives: Syntac/Heliobond (Ivoclar-Vivadent) or Adper-Scotchbond-1XT (3M-ESPE). The adhesives were cured by using a LED-unit (Bluephase (R), Ivoclar Vivadent) with three different curing times (10 s, 20 s and 30 s) under two ceramics (IPS-e. max-Press, Ivoclar-Vivadent; IPS-Empress (R) CAD, Ivoclar-Vivadent) of different thicknesses (0 mm, 0.75 mm, 2 mm). Thirty groups were included, each containing 60 measurements. Micromechanical properties (Hardness, HV; indentation modulus, E; and creep, Cr) of the adhesives were measured with an automatic microhardness indenter (Fisherscope H100C, Germany). Data were statistically analyzed by using one-way ANOVA and Tukey's post-hoc test, as well as a multivariate analysis to test the influence of the study parameters (SPSS 18.0). Results. Significant differences were observed between the micromechanical properties of the adhesives (p < 0.05). The ceramic type showed the highest effect on HV (Partial-eta squared (eta(2)) = 0.109) of the tested adhesives, while E (eta(2) = 0.275) and Cr (eta(2) = 0.194) were stronger influenced by the adhesive type. Ceramic thickness showed no effect on the E and Cr of the adhesives. Conclusions. The adhesive bonding agents used in this study performed well by curing through different thicknesses of ceramics. The micromechanical properties of the adhesives were determined by the adhesive type and were less influenced by ceramic type and curing time.
引用
收藏
页码:543 / 548
页数:6
相关论文
共 50 条
  • [21] Wear resistance of a novel light-cured ceramic stain system
    Lee, S
    Giordano, R
    Nathanson, D
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 124 - 124
  • [22] Color stability of a new light-cured ceramic stain system
    Lee, S
    Nathanson, D
    Giordano, R
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 123 - 123
  • [23] Influence of ceramic thickness on mechanical properties and polymer structure of dual-cured resin luting agents
    Meng, Xiangfeng
    Yoshida, Keiichi
    Atsuta, Mitsuru
    DENTAL MATERIALS, 2008, 24 (05) : 594 - 599
  • [24] Influence of instrument compliance and specimen thickness on the polymerization shrinkage stress measurement of light-cured composites
    Lee, Sue Hyun
    Chang, Juhea
    Ferracane, Jack
    Lee, In Bog
    DENTAL MATERIALS, 2007, 23 (09) : 1093 - 1100
  • [25] Highly transparent glass bonds: Quick processes with light-cured adhesive
    Witek, Günther
    Adhaesion Kleben und Dichten, 2008, (10): : 14 - 17
  • [26] Bond failure with a light-cured resin adhesive - A retrospective analysis.
    McFadzean, R
    Cattanach, D
    Pattison, J
    Millett, DT
    Hallgren, A
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1062 - 1062
  • [27] Easy Debonding of Ceramic Brackets Bonded with a Light-Cured Orthodontic Adhesive Containing Microcapsules with a CO2 Laser
    Arima, Shiori
    Namura, Yasuhiro
    Tamura, Takahiko
    Shimizu, Noriyoshi
    PHOTOMEDICINE AND LASER SURGERY, 2018, 36 (03) : 162 - 168
  • [28] Bonding of light-cured glass ionomer to polycarbonate resin with primers.
    Arakawa, N
    Itoh, T
    Matsumoto, M
    Yamada, I
    Fujita, N
    Fukushima, T
    Inoue, Y
    Miyazaki, K
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 679 - 679
  • [29] Light-cured sealants with fluoride: shear bonding strength and ARI.
    Primo, L
    Chevitarese, LM
    Souza, RB
    Chevitarese, O
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 968 - 968
  • [30] SHEAR-STRESS OF CERAMIC BRACKETS - LIGHT-CURED VERSUS CONCISE
    BARON, DI
    PONTIER, JP
    GUZMAN, RC
    RUDERT, MJ
    JOURNAL OF DENTAL RESEARCH, 1990, 69 : 313 - 313