Aortic Artery and Cardiac Valve Calcification are Associated with Mortality in Chinese Hemodialysis Patients: A 3.5 Years Follow-up

被引:21
|
作者
Chen, Xiao-Nong [1 ]
Chen, Zi-Jin [1 ]
Ma, Xiao-Bo [1 ]
Ding, Bei [2 ]
Ling, Hua-Wei [2 ]
Shi, Zhong-Wei [3 ]
Chen, Nan [1 ]
机构
[1] Shanghai Jiao Tong Univ, Ruijin Hosp, Dept Nephrol, Shanghai 200025, Peoples R China
[2] Shanghai Jiao Tong Univ, Ruijin Hosp, Dept Radiol, Shanghai 200025, Peoples R China
[3] Shanghai Jiao Tong Univ, Ruijin Hosp, Dept Cardiol, Shanghai 200025, Peoples R China
关键词
FGF23; Hemodialysis; Mortality; Vascular Calcification; CHRONIC KIDNEY-DISEASE; GROWTH-FACTOR; 23; LEFT-VENTRICULAR HYPERTROPHY; STAGE RENAL-DISEASE; MAINTENANCE HEMODIALYSIS; CARDIOVASCULAR MORTALITY; DIALYSIS PATIENTS; ALL-CAUSE; VITAMIN-D; VALVULAR CALCIFICATION;
D O I
10.4103/0366-6999.167315
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study was to investigate the relationship among aortic artery calcification (AAC), cardiac valve calcification (CVC), and mortality in maintenance hemodialysis (MHD) patients. Methods: All MHD patients in Shanghai Ruijin Hospital in July 2011 were included. To follow up for 42 months, clinical data, predialysis blood tests, echocardiography, and lateral lumbar X-ray plain radiography results were collected. Plasma FGF23 level was measured using a C-terminal assay. Results: Totally, 110 MHD patients were involved in this study. Of which, 64 (58.2%) patients were male, the mean age was 55.2 1.4 years old, and the median dialysis duration was 29.85 (3.0-225.5) months. About 25.5% of the 110 MHD patients had CVC from echocardiography while 61.8% of the patients had visible calcification of aorta from lateral lumbar X-ray plain radiography. After 42 months follow-up, 25 (22.7%) patients died. Kaplan-Meier analysis showed that patients with AAC or CVC had a significant greater number of all-cause and cardiovascular deaths than those without. In multivariate analyses, the presence of AAC was a significant factor associated with all-cause mortality (hazard ratio [HR]: 3.149, P = 0.025) in addition to lower albumin level and lower 25-hydroxy Vitamin D (25(OH)D) level. The presence of CVC was a significant factor associated with cardiovascular mortality (HR: 3.800, P = 0.029) in addition to lower albumin level and lower 25(OH)D level. Conclusion: Lateral lumbar X-ray plain radiography and echocardiography are simple methods to detect AAC and CVC in dialysis patients. The presence of AAC and CVC was independently associated with mortality in MHD patients. Regular follow-up by X-ray and echocardiography could be a useful method to stratify mortality risk in MHD patients.
引用
收藏
页码:2764 / 2771
页数:8
相关论文
共 50 条
  • [31] LONG-TERM FOLLOW-UP OF PATIENTS WITH AORTIC VALVE REPLACEMENT
    REED, W
    DUNN, M
    [J]. CIRCULATION, 1970, 41 (05) : II44 - &
  • [32] FOLLOW-UP OF PATIENTS TREATED WITH BALLOON DILATATION OF THE AORTIC-VALVE
    TEIEN, D
    [J]. BRITISH HEART JOURNAL, 1990, 64 (01): : 107 - 107
  • [33] HOMOGRAFT REPLACEMENT OF AORTIC VALVE - FOLLOW-UP STUDIES IN 12 PATIENTS
    DAVIES, H
    ROBERTS, CI
    LESSOF, MH
    ROSS, DN
    [J]. LANCET, 1965, 1 (7392): : 926 - +
  • [34] A 5 years follow-up for ischemic cardiac outcomes in patients with carotid artery calcification on panoramic radiographs confirmed by doppler ultrasonography in Turkish population
    Akkemik, Ozlem
    Kazaz, Hakki
    Tamsel, Sadik
    Dundar, Nesrin
    Sahinalp, Sahin
    Ellidokuz, Hulya
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2020, 49 (04)
  • [35] Usefulness of MRI in the follow-up of patients with repaired aortic coarctation and bicuspid aortic valve
    Quenot, JP
    Boichot, C
    Petit, A
    Falcon-Eicher, S
    d'Athis, P
    Bonnet, C
    Wolf, JE
    Louis, P
    Brunotte, F
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 103 (03) : 312 - 316
  • [36] 20 YEARS FOLLOW-UP OF PATIENTS WITH MITRAL-VALVE REPAIR
    TANDON, AP
    HASSAN, SS
    IONESCU, MI
    [J]. CIRCULATION, 1980, 62 (04) : 293 - 293
  • [37] Reconstructed bicuspid aortic valve after 10 years: Clinical and echocardiographic follow-up
    Kasimir, MT
    Simon, P
    Seebacher, G
    Deviatko, E
    Simon-Kupilik, N
    Moritz, A
    Wolner, E
    Moidl, R
    [J]. HEART SURGERY FORUM, 2004, 7 (05): : E485 - E489
  • [38] AORTIC-VALVE REPLACEMENT WITH CRYOPRESERVED PULMONARY ALLOGRAFTS - 5 YEARS FOLLOW-UP
    MAIR, R
    HARRINGER, W
    WIMMERGREINECKER, G
    KLIMA, U
    GROSS, C
    PESCHL, F
    BRUCKE, P
    [J]. ANNALS OF THORACIC SURGERY, 1995, 60 (02): : S185 - S188
  • [39] Homograft Implantation for Aortic Valve Replacement Since 15 Years: Results and Follow-up
    Kilian, Eckehard
    Fries, Florian
    Kowert, Anke
    Vogt, Ferdinand
    Kreuzer, Eckart
    Reichart, Bruno
    [J]. HEART SURGERY FORUM, 2010, 13 (04): : E238 - E242
  • [40] Aortic valve function after balloon dilatation in 184 paediatric patients after 17 years follow-up
    Fratz, S
    Gildein, HP
    Balling, G
    Genz, T
    Eicken, A
    Sebening, W
    Hess, J
    [J]. EUROPEAN HEART JOURNAL, 2004, 25 : 447 - 447