Relation between B-mode Gray-scale Median and Clinical Features of Carotid Stenosis Vulnerability

被引:11
|
作者
Kolkert, Joe L. [1 ]
Meerwaldt, Robbert [2 ]
Loonstra, Jan [1 ]
Schenk, Miranda [3 ]
van der Palen, Job [4 ]
van den Dungen, Jan J. [1 ]
Zeebregts, Clark J. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Surg, Div Vasc Surg, Groningen, Netherlands
[2] Med Spectrum Twente, Dept Surg, Enschede, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Div Clin Neurophysiol, Dept Neurol, Groningen, Netherlands
[4] Med Spectrum Twente, Dept Clin Epidemiol, Enschede, Netherlands
关键词
CEREBROVASCULAR SYMPTOMS; PLAQUE ECHOLUCENCY; HIGH-RISK; ENDARTERECTOMY; EVENTS; TRIALS; STROKE;
D O I
10.1016/j.avsg.2013.04.025
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Vulnerability of the carotid plaque might be useful as a predictor for ischemic stroke risk. The gray-scale median (GSM) of the carotid plaque at B-mode imaging has been described as an objective tool to quantify vulnerability. However, its use is disputed in the published literature. This study sought to validate the GSM as a predictor for carotid plaque vulnerability. Methods: We included 89 consecutive patients (64 men; mean +/- SD age: 68 +/- 1 years) who were evaluated for carotid endarterectomy. The GSM was derived from preoperative B-mode images and related to the presence of clinical symptoms, the presence of ipsilateral infarction on neuroimaging, and to the number of intraoperative ipsilateral microemboli (ME) detected by transcranial Doppler ultrasonography. In addition, we combined the GSM with its standard deviation (GSM-SD), which we hypothesized to be a measure for plaque heterogeneity and thereby vulnerability. Results: B-mode imaging revealed a wide variety in GSM among all plaques (median: 36; range: 6-89). The GSM could not be related to cardiovascular risk factors and was not different between symptomatic and asymptomatic patients (37.8 +/- 8.9 vs 37.6 +/- 17.1; P = 0.97). The GSM of plaques in patients with ipsilateral ischemic lesions on neuroimaging did also not differ from plaques in patients without (36.0 +/- 14.6 vs 37.8 +/- 16.9; P = 0.64). Finally, no relation between GSM and the presence of intraoperative ME (Spearman correlation; n = 73; rho = 0.039; P = 0.75) was found. Combining GSM with its GSM-SD also could not identify more vulnerable plaques. Conclusions: No relation was found between the GSM and any clinical, radiologic, or intra-and postoperative neurologic phenomena. These data showed no additional value of the use of GSM in evaluating plaque vulnerability.
引用
收藏
页码:404 / 410
页数:7
相关论文
共 50 条
  • [21] Grading internal carotid artery stenosis using B-mode ultrasound (in vivo study)
    Jmor, S
    El-Atrozy, T
    Griffin, M
    Tegos, T
    Danjhl, S
    Nicolaides, A
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1999, 18 (04) : 315 - 322
  • [22] Is B-mode ultrasound alone a sufficient screening tool for carotid stenosis? A pilot study
    Bhandari T.
    Socransky S.J.
    [J]. Critical Ultrasound Journal, 2014, 6 (1)
  • [23] ECO B-MODE ASSESSMENT OF THE RELATIONSHIP BETWEEN HYPERCHOLESTEROLEMIA AND CAROTID ATHEROSCLEROSIS
    FERUGLIO, FS
    FISICARO, M
    TONIZZO, M
    CATTIN, L
    DACOL, PG
    NADALUT, D
    [J]. ADVANCES IN VASCULAR PATHOLOGY 1989, VOLS 1 & 2, 1989, 868 : 89 - 92
  • [24] Stratified gray-scale median analysis and color mapping of the carotid plaque - Correlation with endarterectomy specimen histology of 28 patients
    Sztajzel, R
    Momjian, S
    Momjian-Mayor, I
    Murith, N
    Djebaili, K
    Boissard, G
    Comelli, M
    Pizolatto, G
    [J]. STROKE, 2005, 36 (04) : 741 - 745
  • [25] B-mode ultrasonography and gray scale histogram for evaluation of the nuchal ligament in Quarter horse
    Santos, Wildemberto A.
    Vettorato, Michel C.
    Fogaca, Jessica L.
    Mazzante, Nayara M. G.
    Oliveira, Fernanda G.
    Nogueira, Guilherme P.
    Luvizotto, Maria C. R.
    Machado, Vania M. V.
    [J]. PESQUISA VETERINARIA BRASILEIRA, 2019, 39 (08): : 663 - 667
  • [26] Characteristics of earlier atherosclerotic involvement in adolescent patients with Kawasaki disease and coronary artery lesions: Significance of gray scale median on B-mode ultrasound
    Noto, Nobutaka
    Okada, Tomoo
    Abe, Yuriko
    Miyashita, Michio
    Kanamaru, Hiroshi
    Karasawa, Kensuke
    Ayusawa, Mamoru
    Sumitomo, Naokata
    Mugishima, Hideo
    [J]. ATHEROSCLEROSIS, 2012, 222 (01) : 106 - 109
  • [27] B-mode ultrasound assessment of carotid artery structural features in patients with normocalcaemic hyperparathyroidism
    Elbuken, Gulsah
    Aydin, Cihan
    Ozturk, Beyza Olcay
    Aykac, Huseyin
    Topcu, Birol
    Zuhur, Sayid Shafi
    [J]. ENDOKRYNOLOGIA POLSKA, 2023, 74 (01) : 67 - 73
  • [28] Comparison of Multiresolution Features for Texture Classification of Carotid Atherosclerosis From B-Mode Ultrasound
    Tsiaparas, Nikolaos N.
    Golemati, Spyretta
    Andreadis, Ioannis
    Stoitsis, John S.
    Valavanis, Ioannis
    Nikita, Konstantina S.
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (01): : 130 - 137
  • [29] Carotid Plaque Strain Characterization in Clinical B-Mode Ultrasound Image Sequences
    Khan, Amir A.
    Hecker, Joseph C.
    Hatsukami, Tom
    Sikdar, Siddhartha
    Lal, Brajesh K.
    [J]. JOURNAL OF VASCULAR SURGERY, 2016, 64 (03) : 846 - 847
  • [30] Correlation between ultrasound B-mode images of carotid plaque and histological examination
    Jespersen, SK
    Gronholdt, MLM
    Wilhjelm, JE
    Wiebe, B
    Hansen, LK
    Sillesen, H
    [J]. 1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 1065 - 1068