Post-implant dosimetry using a Monte Carlo dose engine: A new clinical standard

被引:0
|
作者
Beaulieu, L.
Carrier, J.
d'Amours, M.
Verhaegen, F.
Martin, A.
Vigneault, E.
机构
[1] CHUQ, Dept Radiooncol, Quebec City, PQ, Canada
[2] CHUM, Dept Radiooncol, Montreal, PQ, Canada
[3] MUHC, Med Phys Unit, Montreal, PQ, Canada
关键词
D O I
10.1016/j.ijrobp.2006.07.164
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
133
引用
收藏
页码:S74 / S74
页数:1
相关论文
共 50 条
  • [1] Postimplant dosimetry using a Monte Carlo dose calculation engine:: A new clinical standard
    Carrier, Jean-Francois
    D'Amours, Michel
    Verhaegen, Frank
    Reniers, Brigitte
    Martin, Andre-Guy
    Vigneault, Eric
    Beaulieu, Luc
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (04): : 1190 - 1198
  • [2] Should Monte Carlo become the standard post-implant dose calculation method?
    Beaulieu, L.
    Carrier, J-F.
    Renier, B.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S420 - S420
  • [3] Monte Carlo dose calculations of clinical post-implant cases: A comparison to the TG43 standard
    Beaulieu, L.
    Carrier, J-F.
    D'Amours, M.
    Martin, A-G.
    Vigneault, E.
    RADIOTHERAPY AND ONCOLOGY, 2006, 80 : S42 - S43
  • [4] Calcifications and tissue composition in post-implant prostate dosimetry: a clinical study with Monte Carlo
    Carrier, J. F.
    D'Amours, M.
    Martin, A.
    Vigneault, E.
    Beaulieu, L.
    MEDICAL PHYSICS, 2006, 33 (07) : 2674 - 2674
  • [5] A Monte Carlo post-implant prostate dosimetry study: Interseed attenuation, tissue composition, and calcification
    Carrier, J. F.
    D'Amours, M.
    Martin, A.
    Vigneault, E.
    Beaulieu, L.
    MEDICAL PHYSICS, 2006, 33 (06) : 2199 - 2199
  • [6] Post-Implant Dosimetry On Prostatectomy CivaSheet Implant
    Sheu, R.
    Powers, A.
    Stock, R.
    Lo, Y.
    MEDICAL PHYSICS, 2019, 46 (06) : E200 - E200
  • [7] MCPI, an accelerated Monte Carlo dose-calculation engine for real-time prostate implant dosimetry
    Chibani, O
    Williamson, J
    MEDICAL PHYSICS, 2005, 32 (06) : 2165 - 2165
  • [8] A CT Based Monte Carlo Dosimetry for Post Implant LDR Brachytherapy
    Hadad, K.
    Ramzanzadeh, A.
    Hamilton, R.
    Watchman, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [9] Importance of post-implant dosimetry in permanent prostate brachytherapy
    Stock, RG
    Stone, NN
    EUROPEAN UROLOGY, 2002, 41 (04) : 434 - 439
  • [10] BREAST TISSUE MODELING IN MONTE CARLO POST-IMPLANT EVALUATION OF BREAST LDR BRACHYTHERAPY
    Afsharpour, H.
    Landry, G.
    Reniers, B.
    Pignol, J. P.
    Beaulieu, L.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S30 - S31