MCPI, an accelerated Monte Carlo dose-calculation engine for real-time prostate implant dosimetry

被引:0
|
作者
Chibani, O [1 ]
Williamson, J [1 ]
机构
[1] Virginia Commonwealth Univ, Richmond, VA 23284 USA
关键词
D O I
10.1118/1.1998673
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present a new accelerated Monte Carlo code (MCPI: Monte Carlo for Prostate Implant) intended for use as a dose calculation engine for planning clinical prostate implants. MCPI simulates physically a set of radioactive seeds with arbitrary positions and orientations, merged in a 3D CT‐based heterogeneous phantom representing the prostate and surrounding tissue. Method and Materials: MCPI uses a phase space data source‐model to account for seed self‐absorption and seed anisotropy. A “hybrid geometry” model (full 3D seed geometry merged in a 3D mesh of voxels) is developed for rigorous treatment of the interseed attenuation effect. MCPI is based upon the GEPTS general‐purpose Monte Carlo code. Compton scattering, coherent scattering, and photoelectric effect (with emission of fluorescence X‐rays) are modeled in detail, using the XCOM/EPDL97/NIST95 cross‐section data. MCPI is benchmarked against the MCNP5 code for the case of an idealized prostate implant, consisting of 83 [formula omitted] (or [formula omitted]) seeds. Results: MCNP5 and MCPI are in excellent agreement. The average difference between the dose distributions from the two codes is less than 0.5% for both seed models. For a 2×2×2‐mm3 voxel mesh, MCPI calculates the [formula omitted] and [formula omitted] prostate dose distributions with 2% average statistical uncertainty in 2.1 to 2.2 minutes using a single Pentium 4 PC. More than 3 hours calculation time is required for MCNP5 to achieve the same statistical precision. MCPI is about 90 and 700 times faster than MCNP5 for 2 and 1‐mm3 voxels, respectively. Conclusion: The use of multiprocessor parallel calculation can further increase the speed of MCPI and makes sub‐minute dose calculations for prostate implant planning a reality. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2165 / 2165
页数:1
相关论文
共 50 条
  • [1] MCPI©:: A sub-minute Monte Carlo dose calculation engine for prostate implants
    Chibani, O
    Williamson, JF
    [J]. MEDICAL PHYSICS, 2005, 32 (12) : 3688 - 3698
  • [2] Complexity of Monte Carlo and deterministic dose-calculation methods
    Borgers, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (03): : 517 - 528
  • [3] Real-time hybrid Monte Carlo for dose calculation in proton therapy
    Ibanez, P.
    Valladolid, V.
    Villa-Abaunza, A.
    Espinosa, A.
    Arias, F.
    Galve, P.
    Sanchez-Parcerisa, D.
    Udias, J. M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1532 - S1533
  • [4] Towards real-time photon Monte Carlo dose calculation in the cloud
    Ziegenhein, Peter
    Kozin, Igor N.
    Kamerling, Cornelis Ph
    Oelfke, Uwe
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (11): : 4375 - 4389
  • [5] Postimplant dosimetry using a Monte Carlo dose calculation engine:: A new clinical standard
    Carrier, Jean-Francois
    D'Amours, Michel
    Verhaegen, Frank
    Reniers, Brigitte
    Martin, Andre-Guy
    Vigneault, Eric
    Beaulieu, Luc
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (04): : 1190 - 1198
  • [6] Monte Carlo simulations for configuring and testing an analytical proton dose-calculation algorithm
    Newhauser, Wayne
    Fontenot, Jonas
    Zheng, Yuanshui
    Polf, Jerimy
    Titt, Uwe
    Koch, Nicholas
    Zhang, Xiaodong
    Mohan, Radhe
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15): : 4569 - 4584
  • [7] A patient-specific Monte Carlo dose-calculation method for photon beams
    Wang, L
    Chui, CS
    Lovelock, M
    [J]. MEDICAL PHYSICS, 1998, 25 (06) : 867 - 878
  • [8] Post-implant dosimetry using a Monte Carlo dose engine: A new clinical standard
    Beaulieu, L.
    Carrier, J.
    d'Amours, M.
    Verhaegen, F.
    Martin, A.
    Vigneault, E.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S74 - S74
  • [9] A Methodology for Monte Carlo Simulation Time Reduction in Dose Calculation for Reference Dosimetry
    Reis, C.
    Nicolucci, P.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3714 - 3714
  • [10] Implementation of a Near Real-Time Dose Calculation Engine for IMRT
    Zou, W.
    Zhu, T.
    Chang, C.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)