A novel enzyme-linked immunosorbent assay for detection of Escherichia coli O157:H7 using immunomagnetic and beacon gold nanoparticles

被引:74
|
作者
Shen, Zhiqiang [1 ]
Hou, Nannan [1 ]
Jin, Min [1 ]
Qiu, Zhigang [1 ]
Wang, Jingfeng [1 ]
Zhang, Bin [1 ]
Wang, Xinwei [1 ]
Wang, Jie [2 ]
Zhou, Dongsheng [2 ]
Li, Junwen [1 ]
机构
[1] Tianjin Inst Hlth & Environm Med, Key Lab Risk Assessment & Control Environm & Food, Tianjin 300050, Peoples R China
[2] Beijing Inst Microbiol & Epidemiol, State Key Lab Pathogen & Biosecur, Beijing 100071, Peoples R China
来源
GUT PATHOGENS | 2014年 / 6卷
基金
中国国家自然科学基金;
关键词
Escherichia coli O157:H7; ELISA; Immunomagnetic nanoparticles; Beacon gold nanoparticles; REAL-TIME PCR; IN-SITU HYBRIDIZATION; ELECTROCHEMICAL IMMUNOSENSOR; GROUND-BEEF; ULTRASENSITIVE DETECTION; E.COLI O157H7; MULTIPLEX PCR; ELISA; FOOD; SALMONELLA;
D O I
10.1186/1757-4749-6-14
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
This paper presents a functional nanoparticle-enhanced enzyme-linked immunosorbent assay (FNP-ELISA) for detection of enterohemorrhagic Escherichia coli (EHEC) O157:H7. Immunomagnetic nanoparticles (IMMPs) conjugated with monoclonal anti-O157:H7 antibody were used to capture E. coli O157:H7. Beacon gold nanoparticles (B-GNPs) coated with polyclonal anti-O157:H7 and biotin single-stranded DNA (B-DNA) were then subjective to immunoreaction with E. coli O157:H7, which was followed by streptavidin-horseradish peroxidase (Strep-HRP) conjugated with B-GNPs based on a biotin-avidin system. The solutions containing E. coli O157:H7, IMMPs, B-GNPs, and Strep-HRP were collected for detecting color change. The signal was significantly amplified with detection limits of 68 CFU mL(-1) in PBS and 6.8 x 10(2) to 6.8 x 10(3) CFU mL(-1) in the food samples. The FNP-ELISA method developed in this study was two orders of magnitude more sensitive than immunomagnetic separation ELISA (IMS-ELISA) and four orders of magnitude more sensitive than C-ELISA. The entire detection process of E. coli O157:H7 lasted only 3 h, and thus FNP-ELISA is considered as a time-saving method.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] A novel enzyme-linked immunosorbent assay for detection of Escherichia coli O157:H7 using immunomagnetic and beacon gold nanoparticles
    Zhiqiang Shen
    Nannan Hou
    Min Jin
    Zhigang Qiu
    Jingfeng Wang
    Bin Zhang
    Xinwei Wang
    Jie Wang
    Dongsheng Zhou
    Junwen Li
    [J]. Gut Pathogens, 6
  • [2] Enzyme-linked immunomagnetic chemiluminescent detection of Escherichia coli O157:H7
    Gehring, AG
    Irwin, PL
    Reed, SA
    Tu, SI
    Andreotti, PE
    Akhavan-Tafti, H
    Handley, RS
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 293 (1-2) : 97 - 106
  • [3] Chemiluminescent enzyme-linked immunosorbent assay on a strip to detect Escherichia coli O157:H7
    Park, Sojung
    Min, Junhong
    Kim, Young-Kee
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2012, 92 (06) : 655 - 664
  • [4] Enzyme-linked immunomagnetic electrochemical detection of live Escherichia coli O157:H7 in apple juice
    Gehring, AG
    Tu, SI
    [J]. JOURNAL OF FOOD PROTECTION, 2005, 68 (01) : 146 - 149
  • [5] Optimization of a fluorescence sandwich enzyme-linked immunosorbent assay for detection of Escherichia coli O157:H7 in apple juice
    Nyquist-Battie, C
    Frank, LE
    Lund, D
    Lim, DV
    [J]. JOURNAL OF FOOD PROTECTION, 2004, 67 (12) : 2756 - 2759
  • [6] Enzyme-linked Immunosorbent assay of Escherichia coli O157:H7 in surface enhanced Poly(Methyl methacrylate) microchannels
    Bai, Yunling
    Huang, Wei-Cho
    Yang, Shang-Tian
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 2007, 98 (02) : 328 - 339
  • [7] QCM immunosensor detection of Escherichia coli O157:H7 based on beacon immunomagnetic nanoparticles and catalytic growth of colloidal gold
    Shen, Zhi-Qiang
    Wang, Jing-Feng
    Qiu, Zhi-Gang
    Jin, Min
    Wang, Xin-Wei
    Chen, Zhao-Li
    Li, Jun-Wen
    Cao, Fu-Huan
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (07): : 3376 - 3381
  • [8] Enzyme-linked immunomagnetic chemiluminescence incorporating anti-H7 and anti-O157 antibodies for the detection of Escherichia coli O157:H7
    Gehring, Andrew G.
    Irwin, Peter L.
    Reed, Sue A.
    Tu, Shu-I
    [J]. JOURNAL OF RAPID METHODS AND AUTOMATION IN MICROBIOLOGY, 2006, 14 (04): : 349 - 361
  • [9] Microsystem for the immunomagnetic detection of Escherichia coli O157:H7
    Mujika, M.
    Arana, S.
    Castano, E.
    Tijero, M.
    Vilares, R.
    Ruano-Lopez, J. M.
    Cruz, A.
    Sainz, L.
    Berganza, J.
    [J]. PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2008, 205 (06): : 1478 - 1483
  • [10] Detection of Escherichia coli O157 in foods by a novel polymyxin-based enzyme-linked immunosorbent assay
    Blais, BW
    Leggate, J
    Bosley, J
    Martinez-Perez, A
    [J]. JOURNAL OF FOOD PROTECTION, 2005, 68 (02) : 233 - 238