Mammographic density measurement: A comparison of automated volumetric density measurement to BIRADS

被引:5
|
作者
McEntee, Mark F. [1 ]
Damases, Christine N. [1 ]
机构
[1] Univ Sydney, Lidcombe, NSW 2141, Australia
关键词
Breast density; Mammography; Automated software (Volpara); BIRADS categories; BI-RADS CATEGORIES; BREAST-CANCER RISK;
D O I
10.1117/12.2042966
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The aim of this study is to compare mammographic breast density assessment with automated volumetric software with Breast Imaging Reporting and Data System (BIRADS) categorization by radiologists on two imaging systems. A data set of 120 mammograms was classified by twenty American Board of Radiology (ABR) Examiners. The mammograms were of 20 women (mean age, 60 years; range, 42-89 years). These women were image twice once with GE system and the following year with Hologic system. These images also had their volumetric density classified by using Volpara Density Grade (VDG). The radiologists were asked to estimate the mammographic density according to BIRADS categories (14). There was a moderate agreement between VDG classification and radiologist BIRADS density shown with Cohen's Kappa (K=0.45; p<0.001). Radiologists estimated percentage density to be lower by an average of 0.37, the radiologist's BIRADS having a mean of 2.13 and the mean VDG higher at 2.50 (t = -11.99; p<0.001). VDG and radiologist's BIRADS showed a positive strong correlation (r=0.84; p<0.001). Radiologist BIRADS and VDG AvBD% also showed a strong positive correlation (r=0.86; p<0.001). There was a large spread of radiologist's BIRADS categories for each of the VDG AvBD% classifications. Using Volpara, the Hologic system showed a higher meanAvBD% (10.02 vs. 9.97). However using BIRADS the Hologic systems showed a lower mean (2.05 vs. 2.21). Automated systems demonstrated higher internal validity. The results demonstrated a moderate agreement and a strong correlation between VDG classification and radiologist BIRADS density assessment.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Comparison of subjective and fully automated methods for measuring mammographic density
    Moshina, Nataliia
    Roman, Marta
    Sebuodegard, Sofie
    Waade, Gunvor G.
    Ursin, Giske
    Hofvind, Solveig
    [J]. ACTA RADIOLOGICA, 2018, 59 (02) : 154 - 160
  • [32] Evaluation of Automated Mammographic Density Classification in Tomosynthesis: Comparison with Radiologists
    Kiziloglu, Hueseyin Alper
    Beyhan, Murat
    Gokce, Erkan
    Birisik, Yasar
    Battal, Muhammet Furkan
    Ceker, Muhammed Erkam
    Demir, Osman
    [J]. EUROPEAN JOURNAL OF THERAPEUTICS, 2024, 30 (03): : 258 - 266
  • [33] Visual versus automatic measurement of mammographic breast density (MBD)
    Izquierdo, M.
    Browne, J.
    Rodriguez, I.
    Tresserra, F.
    Garcia, M.
    Ara, C.
    Baulies, S.
    Pascual, M. A.
    Fabregas, R.
    [J]. EUROPEAN JOURNAL OF CANCER, 2020, 138 : S120 - S120
  • [34] Mammographic Breast Density Evaluation in Korean Women Using Fully Automated Volumetric Assessment
    Youn, Inyoung
    Choi, SeonHyeong
    Kook, Shin Ho
    Choi, Yoon Jung
    [J]. JOURNAL OF KOREAN MEDICAL SCIENCE, 2016, 31 (03) : 457 - 462
  • [35] Validation of a new automated volumetric breast density measurement system as a marker of breast cancer risk
    Pinker, K.
    Perry, N.
    Milner, S.
    Mokbel, K.
    Duffy, S.
    [J]. BREAST CANCER RESEARCH, 2010, 12
  • [36] Validation of a new automated volumetric breast density measurement system as a marker of breast cancer risk
    K Pinker
    N Perry
    S Milner
    K Mokbel
    S Duffy
    [J]. Breast Cancer Research, 12
  • [37] Mammographic Density Assessment by Artificial Intelligence-Based Computer-Assisted Diagnosis: A Comparison with Automated Volumetric Assessment
    Lee, Si Eun
    Son, Nak-Hoon
    Kim, Myung Hyun
    Kim, Eun-Kyung
    [J]. JOURNAL OF DIGITAL IMAGING, 2022, 35 (02) : 173 - 179
  • [38] Mammographic Density Assessment by Artificial Intelligence-Based Computer-Assisted Diagnosis: A Comparison with Automated Volumetric Assessment
    Si Eun Lee
    Nak-Hoon Son
    Myung Hyun Kim
    Eun-Kyung Kim
    [J]. Journal of Digital Imaging, 2022, 35 : 173 - 179
  • [39] Automated volumetric breast density estimation: A comparison with visual assessment
    Seo, J. M.
    Ko, E. S.
    Han, B. -K.
    Ko, E. Y.
    Shin, J. H.
    Hahn, S. Y.
    [J]. CLINICAL RADIOLOGY, 2013, 68 (07) : 690 - 695
  • [40] Assessment of a fully automated, high-throughput mammographic density measurement tool for use with processed digital mammograms
    A. M. Couwenberg
    H. M. Verkooijen
    J. Li
    R. M. Pijnappel
    K. R. Charaghvandi
    M. Hartman
    C. H. van Gils
    [J]. Cancer Causes & Control, 2014, 25 : 1037 - 1043