Histological comparison of corneal ablation with Er:YAG laser, Nd:YAG optical parametric oscillator, and excimer laser

被引:0
|
作者
Telfair, WB
Bekker, C
Hoffman, HJ
Yoder, PR
Nordquist, RE
Eiferman, RA
Zenzie, HH
机构
[1] IRVis Inc, San Jose, CA 95131 USA
[2] Wound Healing Oklahoma, Oklahoma City, OK USA
[3] VA Med Ctr, Res Serv, Louisville, KY USA
[4] Schwartz Electro Opt Inc, Concord, MA USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To use histological techniques to assess and compare the ablation depth, local damage, and surface quality of corneal ablations by a Q-switched Er:YAG laser, an optical parametric oscillator laser at 2.94 mu m, a long pulse Er:YAG laser, and a 193-nm excimer laser. METHODS: Human cadaver eyes and in vivo eat eyes were treated with a 6.0-mm diameter, 30-mu m-deep phototherapeutic keratectomy ablation and a 6.0-mm diameter, -5.00-D photorefractive keratectomy ablation. Human cadaver eyes mere also treated with a 5.0-mm diameter, -5.00-D laser in situ keratomileusis (LASIK) ablation, Fluences and pulse widths used were 200 mJ/cm(2) and 70 ns for the Q-switched Er:YAG, 150 mJ/cm(2) and 70 ns for the optical parametric oscillator laser (OPO), 500 mJ/cm(2) and 50 microseconds for the long pulse Er:YAG, and 160 mj/cm(2) and 20 ns for the excimer laser In the ablation rate study, 12 porcine eyes were ablated by the OPO laser with a range of layers and at different fluences ranging from 60 to 150 mJ/cm(2), all using a 1.5-mm spot on the eye. The ablation depth of these acute ablations was evaluated by Light microscopy examination. RESULTS: In the acute damage study, light microscopy showed a thin surface layer in all samples with minimal thermal damage except on the long pulse Er:YAG corneas. Transmission electron microscopy revealed less than 0.3-mu m surface damage for an specimens of both the optical parametric oscillator and the excimer laser samples with no evidence of collagen shrinkage. Transmission electron microscopy showed damage layers of 0.5 to 3 mu m for Q-switched Er:YAG and 3 to 10 mu m for long pulse Er:YAG. Scanning electron microscopy showed smooth surfaces in all eyes, although the excimer was the roughest. In the porcine eye study ablations were produced in both PTK and PRK modes with the ablation rate per layer increasing with the fluence. At 120 mJ/cm(2), the average ablation rate was 1.9 mu m per layer. CONCLUSIONS: The histology from the short pulse mid-infrared optical parametric oscillator laser at 2.94 mu m was comparable to the 193-nm excimer with a smooth, damage-free, ablation zone when performing PRK and LASIK.
引用
收藏
页码:40 / 50
页数:11
相关论文
共 50 条
  • [31] ER YAG LASER ABLATION OF TISSUE - MEASUREMENT OF ABLATION RATES
    WALSH, JT
    DEUTSCH, TF
    LASERS IN SURGERY AND MEDICINE, 1989, 9 (04) : 327 - 337
  • [32] Comparison between the removal effect of mechanical, Nd:YAG, and Er:YAG laser systems in carious dentin
    Yamada, Y
    Hossain, M
    Nakamura, Y
    Suzuki, N
    Matsumoto, K
    JOURNAL OF CLINICAL LASER MEDICINE & SURGERY, 2001, 19 (05): : 239 - 243
  • [33] Er:YAG laser ablation of cerebellar and cerebral tissue
    Gülsoy, M
    Çelikel, T
    Kurt, A
    Canbeyli, R
    Çilesiz, I
    LASERS IN MEDICAL SCIENCE, 2001, 16 (01) : 40 - 43
  • [34] Er:YAG Laser Ablation of Bone in Experimental Diabetics
    Akyol, Utkan
    Gungormus, Metin
    PHOTOMEDICINE AND LASER SURGERY, 2010, 28 (04) : 477 - 482
  • [35] Noncontact Er:YAG laser ablation: Clinical evaluation
    Dostalova, Tatjana
    Jelinkova, Helena
    Kucerova, Hana
    Krejsa, Otakar
    Hamal, Karel
    Kubelka, Jiri
    Prochazka, Stanislav
    Journal of Clinical Laser Medicine and Surgery, 1998, 16 (05): : 273 - 282
  • [36] Er:YAG Laser Ablation of Cerebellar and Cerebral Tissue
    M. Gülsoy
    T. Çelikel
    A. Kurt
    R. Canbeyli
    I. Çilesiz
    Lasers in Medical Science, 2001, 16 : 40 - 43
  • [37] Lens ablation with a mini Er:YAG laser.
    Shen, J
    Joos, KM
    Lim, C
    O'Day, DM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S11 - S11
  • [38] Noncontact Er:YAG laser ablation:: Clinical evaluation
    Dostalova, T
    Jelinkova, H
    Kucerova, H
    Krejsa, O
    Hamal, K
    Kubelka, J
    Prochazka, S
    JOURNAL OF CLINICAL LASER MEDICINE & SURGERY, 1998, 16 (05): : 273 - 282
  • [39] Nd:YAG Laser Pumped HgGa2S4 Parametric Oscillator
    Kato, Kiyoshi
    Miyata, Kentaro
    NONLINEAR FREQUENCY GENERATION AND CONVERSION: MATERIALS, DEVICES, AND APPLICATIONS XII, 2013, 8604
  • [40] MEASUREMENT OF ER - YAG LASER ABLATION PLUME DYNAMICS
    WALSH, JT
    DEUTSCH, TF
    APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1991, 52 (03): : 217 - 224