Accuracy of different definitive impression techniques with the all-on-4 protocol

被引:8
|
作者
Ozan, Oguz [1 ]
Hamis, Oguz [2 ]
机构
[1] Near East Univ, Fac Dent, Dept Prosthodont, Nicosia, Mersin, Turkey
[2] Near East Univ, Fac Dent, Nicosia, Mersin, Turkey
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2019年 / 121卷 / 06期
关键词
IMPLANT ANGULATION; CLINICAL ACCURACY;
D O I
10.1016/j.prosdent.2018.08.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. A nonpassive fit of implant-supported restorations can jeopardize the biological and mechanical success of the treatment. Data regarding the fit of different impression techniques for the all-on-4 protocol are limited. Purpose. The purpose of this in vitro study was to digitally evaluate 4 different impression techniques used with the all-on-4 protocol, with distal multiunit analogs positioned in 4 different angulations. Material and methods. Four maxillary definitive cast models with 4 multiunit analogs (T0 32202; NucleOSS) were fabricated according to the all-on-4 treatment protocol. In the anterior region, the analogs were positioned in a parallel direction, whereas in the posterior region, they were positioned in different angulations (0, 10, 20, and 30 degrees). One hundred and sixty models were obtained by using 4 different impression techniques (closed tray without plastic cap, closed tray with plastic cap, splinted open tray, sectioned resplinted open tray) (n=10) and polyvinyl siloxane impression material. Definitive casts and definitive duplicate casts were scanned using a modified laser scanner (Activity 880; Smart Optics Sensortechnik GmbH), and data were transferred to a software program (VRMesh Studio; Virtual Grid Inc). The definitive casts and definitive duplicate cast scans were digitally aligned. Angular and linear deviations in all axes (x, y, and z) of the analogs between definitive and duplicate casts were calculated and subjected to statistical analyses (alpha=.05). Results. Mean angular deviations were in the range of 0.03 to 0.16 degrees, and linear deviations were in the range of 0.10 to 0.75 mm. The increased angulation between impression copings caused higher linear and angular deviations when closed-tray impression techniques were used (P<.05). Conclusions. Reduced linear and angular displacements were obtained from the open-tray impression techniques compared with the closed-tray impression techniques in the angulated groups. Angular and linear deviations increased with the increase in the angulation of the posterior analog.
引用
收藏
页码:941 / 948
页数:8
相关论文
共 50 条
  • [1] INFLUENCE OF 4 IMPRESSION TECHNIQUES ON IMPRESSION ACCURACY
    VANVUUREN, PAJ
    FERREIRA, MR
    NEL, JC
    [J]. JOURNAL OF DENTAL RESEARCH, 1982, 61 (04) : 611 - 611
  • [2] Accuracy of Three Implant Impression Techniques with Different Impression Materials and Stones
    Chang, Won-Gun
    Vahidi, Farhad
    Bae, Kwang-Hak
    Lim, Bum-Soon
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (01) : 44 - 47
  • [3] Comparison of Different Impression Techniques When Using the All-on-Four Implant Treatment Protocol
    Siadat, Hakimeh
    Alikhasi, Marzieh
    Beyabanaki, Elaheh
    Rahimian, Susan
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (03) : 265 - 270
  • [4] The speech outcome of definitive obturators constructed using two different impression techniques
    El-Maghraby R.M.
    El-Didi L.M.
    Al-Shimy A.M.
    Abdel Razek M.M.
    [J]. The Egyptian Journal of Otolaryngology, 2016, 32 (1) : 61 - 66
  • [5] Comparison of the Accuracy of Different Transfer Impression Techniques for Osseointegrated Implants
    Zen, Bruno Massucato
    Soares, Eveline Freitas
    Rodrigues, Mariana Agustinho
    Luthi, Leonardo Flores
    Consani, Rafael Leonardo X.
    Mesquita, Marcelo Ferraz
    Pessanha Henriques, Guilherme Elias
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : 662 - 667
  • [6] Evaluation of the accuracy of different transfer impression techniques for multiple implants
    Brigolini de Faria, Julio Cesar
    Silva-Concilio, Lais Regiane
    Claro Neves, Ana Christina
    Miranda, Milton Edson
    Teixeira, Marcelo Lucchesi
    [J]. BRAZILIAN ORAL RESEARCH, 2011, 25 (02) : 163 - 167
  • [7] Accuracy of Different Impression Techniques for Internal-Connection Implants
    Lee, Yun-Jung
    Heo, Seong-Joo
    Koak, Jai-Young
    Kim, Seong-Kyun
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 823 - 830
  • [8] The All-on-4 Shelf: Maxilla
    Jensen, Ole T.
    Adams, Mark W.
    Cottam, Jared R.
    Parel, Stephen M.
    Phillips, William R., III
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (10) : 2520 - 2527
  • [9] Accuracy of Definitive Casts Using 4 Implant-Level Impression Techniques in a Scenario of Multi-Implant System With Different Implant Angulations and Subgingival Alignment Levels
    Martinez-Rus, Francisco
    Garcia, Carmen
    Santamaria, Andrea
    Ozcan, Mutlu
    Pradies, Guillermo
    [J]. IMPLANT DENTISTRY, 2013, 22 (03) : 268 - 276
  • [10] All-on-4 Concept With Use Of Zygoma Implants for Rehabilitation in the Severely Atrophied Maxilla With a Definitive Immediate Restoration
    Brauer, Hans Ulrich
    Mamar, Abdel-Karim
    Bartols, Andreas
    Korsch, Michael
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (03) : 173 - 177