Amperometric Glucose Sensor Based on The Entrapment of Glucose Oxidase in Electrochemically Synthesized Pyrrole/N,N-Dimethylaminopyrrole (Py/DMAPy) Copolymer Film

被引:0
|
作者
Sen, S. [1 ]
机构
[1] Mehmet Akif Ersoy Univ, Dept Chem, Fac Arts & Sci, TR-15100 Burdur, Turkey
关键词
Pyrrole; N; N-Dimethylaminopyrrole; Copolymerization; Glucose oxidase; Sensor; POLYANILINE INVERSE OPALS; GLASSY-CARBON ELECTRODE; ENZYME ELECTRODES; POLYPYRROLE FILMS; COVALENT IMMOBILIZATION; CONDUCTING POLYMERS; BIOSENSOR; PYRROLE; ELECTROPOLYMERIZATION; NANOPARTICLES;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Glucose oxidase (GOx) was entrapped on the films obtained by electrochemical copolymerization of pyrrole (Py) and N,N-dimethylaminopyrrole (DMAPy), to fabricate GOx-immobilized electrodes for amperometric sensing of glucose. Polymeric film was characterized with cyclic voltammetry (CV) and Fourier transform infrared (FTIR) spectroscopy The amperometric response of the enzyme electrode was measured at +0.70V vs. Ag/AgCl, which was due to the electrooxidation of enzymatically, produced H(2)O(2). The effects of the composition of copolymer., pH. temperature and substrate concentration on the response of the enzyme electrode were investigated., The optimum pH was found to be 7.4 at 25 degrees C and response time of enzyme electrode was determined as 45 s. The upper limit of the linear working portion was obtained as 10 mM glucose concentration with a detection limit of (5.0 x 10(-6) M) with the calculated value of apparent Michaelis-Menten constant (KMapp) was 3.70 mM. The activation energy of this immobilized enzyme system were found to be 30.25 kJ mol(-1).
引用
收藏
页码:4063 / 4076
页数:14
相关论文
共 23 条
  • [1] Amperometric glucose sensor based on glucose oxidase immobilized in electrochemically generated poly(ethacridine)
    Xu, JJ
    Chen, HY
    ANALYTICA CHIMICA ACTA, 2000, 423 (01) : 101 - 106
  • [2] Amperometric glucose biosensor based on entrapment of glucose oxidase in a poly(3,4-ethylenedioxythiophene) film
    Nien, Po-Chin
    Tung, Tsai-Shih
    Ho, Kuo-Chuan
    ELECTROANALYSIS, 2006, 18 (13-14) : 1408 - 1415
  • [3] Planar amperometric glucose sensor based on glucose oxidase immobilized by chitosan film on Prussian blue layer
    Zhu, JH
    Zhu, ZQ
    Lai, ZS
    Wang, R
    Guo, XM
    Wu, XQ
    Zhang, GX
    Zhang, ZR
    Zhang, ZR
    Wang, YT
    Chen, ZY
    SENSORS, 2002, 2 (04): : 127 - 136
  • [4] Covalent immobilization of glucose oxidase on the film prepared by electrochemical polymerization of N-phenylglycine for amperometric glucose sensing
    Homma, Toshimasa
    Ichimura, Toshifumi
    Kondo, Mizuki
    Kuwahara, Takashi
    Shimomura, Masato
    EUROPEAN POLYMER JOURNAL, 2014, 51 : 130 - 135
  • [5] An amperometric sensor based on covalent immobilization of glucose oxidase in electropolymerized chloranil-N-aminopyrrole films
    Losada, J
    Armada, MPG
    ELECTROANALYSIS, 2001, 13 (12) : 1016 - 1021
  • [6] A NEW AMPEROMETRIC GLUCOSE SENSOR BASED ON BILAYER FILM COATING OF REDOX-ACTIVE CLAY FILM AND GLUCOSE-OXIDASE ENZYME FILM
    OHSAKA, T
    YAMAGUCHI, Y
    OYAMA, N
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1990, 63 (09) : 2646 - 2652
  • [7] Glucose oxidase immobilized on galvanostatically synthesized poly(N-methylpyrrole)/polyvinyl sulfonate film for determination of glucose
    Shirale, Dhammanand J.
    Gade, Vikas K.
    Gaikwad, Pradeep D.
    Savale, Padmakar A.
    Kakde, Kishor P.
    Kharat, Haridas J.
    Shirsat, Mahendra D.
    INTERNATIONAL JOURNAL OF POLYMER ANALYSIS AND CHARACTERIZATION, 2006, 11 (05) : 369 - 382
  • [8] An amperometric urea biosensor based on covalent immobilization of urease onto an electrochemically prepared copolymer poly (N-3-aminopropyl pyrrole-co-pyrrole) film
    Rajesh
    Bisht, V
    Takashima, W
    Kaneto, K
    BIOMATERIALS, 2005, 26 (17) : 3683 - 3690
  • [9] Amperometric detection of glucose based on immobilizing glucose oxidase on g-C3N4 nanosheets
    Tian, KaiJin
    Liu, Hui
    Dong, YongPing
    Chu, XiangFeng
    Wang, ShangBing
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2019, 581
  • [10] Properties of glucose sensors based on the immobilization of glucose oxidase in N-substituted polypyrrole film
    Yasuzawa, M
    Nieda, T
    Hirano, T
    Kunugi, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 66 (1-3) : 77 - 79