Determination of platinum in tumour tissues after cisplatin therapy by electrothermal atomic absorption spectrometry

被引:22
|
作者
Milacic, R [1 ]
Cemazar, M [1 ]
Sersa, G [1 ]
机构
[1] INST ONCOL,LJUBLJANA 1105,SLOVENIA
关键词
platinum determination; electrothermal atomic absorption spectrometry with Zeeman background correction; aqueous standards and standard addition calibration; tumour tissues;
D O I
10.1016/S0731-7085(97)00045-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple procedure is described for the determination of platinum in tumours after cisplatin therapy. Tumours were digested in 65% nitric acid by incubation at 37 degrees C: for 2 days and platinum analysed under optimum conditions by electrothermal atomic absorption spectrometry with Zeeman background correction. The reproducibility of measurements in general was better than +/- 2%. The calibration graph nias linear from 30.0 up to 1000 mu g l(-1) of platinum, while the limit of detection (3 sigma) was found to be 3.0 mu g l(-1) (sample volume 20 mu). Aqueous standard solutions and the standard addition method were applied ic, the calibration procedure. Under the recommended analytical conditions, the sample matrix did not influence the determination of platinum significantly. In 72% of samples analysed the differences between results obtained by the two calibration procedures did not exceed +/- 5%. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:343 / 348
页数:6
相关论文