An advanced preamplifier for highly segmented germanium detectors

被引:26
|
作者
Pullia, A. [1 ]
Zocca, F.
Pascovici, G.
机构
[1] Univ Milan, Dept Phys, I-20133 Milan, Italy
[2] Ist Nazl Fis Nucl, I-20133 Milan, Italy
[3] Univ Cologne, Inst Kernphys, D-50937 Cologne, Germany
关键词
charge-sensitive preamplifier; gamma ray spectroscopy; germanium detector;
D O I
10.1109/TNS.2006.880402
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a fast low-noise hybrid charge-sensitive preamplifier for germanium position-sensitive gamma-ray detectors. In conjunction with a bulky 36-fold segmented detector it provided an excellent resolution of 1.71/1.77 keV fwhm on the 1.17/1.33 MeV60 Co lines. The preamplifier rise time, as measured at the test bench, is as fast as 7.5 ns, with a detector capacitance of 21 pF and with a 5 m 50 Omega twisted-pair cable connected at its output. The dynamic range of the preamplifier input stage is as large as 92 dB, ranging from 0.275 fC to 9.9 pC, i.e., from 5 keV to 180 MeV in terms of photon energy. On signals larger than 2 MeV a fast reset (similar to 10 MeV/mu s) is enforced to reduce the system dead time. An estimate of the amplitude of such large signals is derived from the reset time, still obtaining a high resolution. Using this technique we achieved an energy resolution of 0.3 % at 16.7 MeV.
引用
收藏
页码:2869 / 2875
页数:7
相关论文
共 50 条
  • [31] PIRE: A GLOBAL CONSORTIUM FOR ADVANCED GERMANIUM DETECTORS AND TECHNOLOGY
    Mei, Dongming
    PROCEEDINGS OF THE SOUTH DAKOTA ACADEMY OF SCIENCE, VOL 94, 2015, 94 : 352 - 352
  • [32] Position sensitive germanium detectors for the advanced compton telescope
    Kroeger, RA
    Johnson, WN
    Kurfess, JD
    Phlips, BF
    Luke, PN
    Momayezi, M
    Warburton, WK
    FIFTH COMPTON SYMPOSIUM, 2000, 510 : 794 - 798
  • [33] Local independent component analysis applied to highly segmented detectors
    Simas Filho, Eduardo F.
    de Seixas, Jose Manoel
    Caloba, Luiz Pereira
    PROCEEDINGS OF 2008 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-10, 2008, : 3005 - 3008
  • [34] Cross-Talk Limits of Highly Segmented Semiconductor Detectors
    Pullia, Alberto
    Weisshaar, Dirk
    Zocca, Francesca
    Bazzacco, Dino
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (03) : 1201 - 1205
  • [35] Cross-Talk Limits of Highly Segmented Semiconductor Detectors
    Pullia, A.
    Weisshaar, D.
    Zocca, F.
    Bazzacco, D.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1707 - +
  • [36] GAMMA-RAY IMAGING LABORATORY MEASUREMENTS USING EXTERNALLY SEGMENTED GERMANIUM DETECTORS
    CALLAS, JL
    MAHONEY, WA
    SKELTON, RT
    VARNELL, LS
    WHEATON, WA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (03) : 121 - 129
  • [37] Tracking γ rays in highly segmented HPGe detectors: A review of AGATA and GRETINA
    Korichi, A.
    Lauritsen, T.
    EUROPEAN PHYSICAL JOURNAL A, 2019, 55 (07):
  • [38] Improved energy resolution of highly segmented HPGe detectors by noise reduction
    A. Wiens
    B. Birkenbach
    B. Bruyneel
    J. Eberth
    H. Hess
    Gh. Pascovici
    P. Reiter
    D. Bazzacco
    E. Farnea
    C. Michelagnoli
    F. Recchia
    The European Physical Journal A, 2013, 49
  • [39] Improved energy resolution of highly segmented HPGe detectors by noise reduction
    Wiens, A.
    Birkenbach, B.
    Bruyneel, B.
    Eberth, J.
    Hess, H.
    Pascovici, Gh
    Reiter, P.
    Bazzacco, D.
    Farnea, E.
    Michelagnoli, C.
    Recchia, F.
    EUROPEAN PHYSICAL JOURNAL A, 2013, 49 (04): : 1 - 10
  • [40] A fast current preamplifier for silicon detectors
    Atkin, E. V.
    Voronin, A. G.
    Klyuev, A. D.
    Merkin, M. M.
    Pakhomov, A. Yu.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2010, 53 (01) : 86 - 88