The respiratory occlusion discrimination task: A new paradigm to measure respiratory interoceptive accuracy

被引:15
|
作者
Van den Houte, Maaike [1 ,2 ,3 ]
Vlemincx, Elke [4 ]
Franssen, Mathijs [5 ]
Van Diest, Ilse [5 ]
Van Oudenhove, Lukas [2 ,6 ]
Luminet, Olivier [1 ,3 ]
机构
[1] UCLouvain, Res Grp Hlth Emot Cognit & Memory, Res Inst Psychol Sci, Louvain La Neuve, Belgium
[2] Katholieke Univ Leuven, Lab Brain Gut Axis Studies LaBGAS, UZ Herestr 49 Box 7003, B-3000 Leuven, Belgium
[3] Fund Sci Res FRS FNRS, Brussels, Belgium
[4] Vrije Univ Amsterdam, Dept Hlth Sci, Amsterdam, Netherlands
[5] Katholieke Univ Leuven, Hlth Psychol Res Grp, Leuven, Belgium
[6] Dartmouth Coll, Cognit & Affect Neurosci Lab, Hanover, NH 03755 USA
关键词
VALIDATION; PERCEPTION; HEARTBEAT; DISORDER; SCALE;
D O I
10.1111/psyp.13760
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
Interoception, or the sense of the internal state of the body, is hypothesized to be essential for a wide range of psychobiological processes and the development and perpetuation of several (mental) health problems. However, the study of interoceptive accuracy, the objectively measured capacity to detect or discriminate conscious bodily signals, has been hampered by the use of tasks with questionable construct validity and is often limited to studying interoception solely in the cardiac domain. We developed a novel task to measure interoceptive accuracy in the respiratory domain, the respiratory occlusion discrimination (ROD) task. In this task, interoceptive accuracy is defined as an individual's ability to detect small differences in lengths of short respiratory occlusions, assessed by means of an adaptive staircase procedure. This article describes a validation study (N = 97) aimed at investigating the internal consistency, test-retest reliability, and discriminant validity of the ROD task. The average just noticeable difference of lengths of respiratory occlusion was 74.22 ms, with large inter-individual variability (SD = 37.1 ms). The results of the validation study indicate acceptable internal consistency (Cronbach's alpha = 0.70), 1-week test-retest reliability (r = 0.53), and discriminant validity, as indicated by a lack of correlation between the ROD task and an auditory discrimination task with identical design (r = 0.18), and a weak correlation with breathing behavior (r = -0.27). The ROD task is a promising novel paradigm to study interoceptive accuracy and its role in various psychobiological processes and disorders.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] ESTABLISHING THE RELATIVE ACCURACY OF 3 NEW DEFINITIONS OF THE ADULT-RESPIRATORY-DISTRESS-SYNDROME
    MOSS, M
    GOODMAN, PL
    HEINIG, M
    BARKIN, S
    ACKERSON, L
    PARSONS, PE
    CRITICAL CARE MEDICINE, 1995, 23 (10) : 1629 - 1637
  • [32] New Outpatient Management Based on a Respiratory Virtual Clinic. An Effective Measure in Times of Austerity
    Figueira Goncalves, Juan Marco
    Hernandez Gracia, M. Carmen
    Batista Martin, Jose Julian
    ARCHIVOS DE BRONCONEUMOLOGIA, 2016, 52 (05): : 279 - 280
  • [33] EXPIRATORY VOLUME CLAMPING (EVC) - A NEW NONINVASIVE METHOD TO MEASURE PASSIVE RESPIRATORY MECHANICS IN INFANTS
    GRUNSTEIN, MM
    SPRINGER, C
    GODFREY, S
    BARYISHAY, E
    VILOZNI, D
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1986, 133 (04): : A8 - A8
  • [34] RESPIRATORY ACOUSTICAL IMPEDANCE - A NEW TECHNIQUE TO MEASURE AIRWAY RESPONSE DURING BRONCHIAL INHALATION CHALLENGES
    FEIHL, F
    BADAN, M
    DEPEURSINGE, F
    DEPEURSINGE, C
    LEUENBERGER, P
    PECOUD, A
    PERRET, C
    ANNALS OF ALLERGY, 1988, 61 (04): : 263 - 268
  • [35] A review of the literature on the accuracy, strengths, and limitations of visual, thoracic impedance, and electrocardiographic methods used to measure respiratory rate in hospitalized patients
    Bawua, Linda K.
    Miaskowski, Christine
    Hu, Xiao
    Rodway, George W.
    Pelter, Michele M.
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2021, 26 (05)
  • [36] A new method to measure real-world respiratory tract deposition of inhaled ambient black carbon
    Madueno, Leizel
    Kecorius, Simonas
    Londahl, Jakob
    Mueller, Thomas
    Pfeifer, Sascha
    Haudek, Andrea
    Mardonez, Valeria
    Wiedensohler, Alfred
    ENVIRONMENTAL POLLUTION, 2019, 248 : 295 - 303
  • [37] A new paradigm in respiratory hygiene: Increasing the cohesivity of airway secretions to improve cough interaction and reduce aerosol dispersion
    Zayas G.
    Dimitry J.
    Zayas A.
    O'Brien D.
    King M.
    BMC Pulmonary Medicine, 5 (1)
  • [38] The Accuracy of the New Landmark Using Respiratory Jugular Venodilation and Direct Palpation in Right Internal Jugular Vein Access
    Seo, Hyungseok
    Jang, Dong-Min
    Yi, Jung-Min
    Min, Hong-Gi
    Hwang, Jai-Hyun
    PLOS ONE, 2014, 9 (07):
  • [39] A Potential New Technique to Measure Respiratory Tidal Volume Using Optical Surface Imaging: A Geometric and Deformable Phantom Study
    Li, G.
    Li, D.
    Cohen, P.
    Ballangrud, A.
    Rimner, A.
    Yorke, E.
    Mechalakos, J.
    Amols, H.
    MEDICAL PHYSICS, 2012, 39 (06) : 3667 - 3668
  • [40] COMPUTER AIDED LUNG SOUND ANALYSIS A Preliminary Study to Assess its Potential as a New Outcome Measure for Respiratory Therapy
    Marques, Alda
    Bruton, Anne
    Barney, Anna
    HEALTHINF 2009: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON HEALTH INFORMATICS, 2009, : 251 - +