The respiratory occlusion discrimination task: A new paradigm to measure respiratory interoceptive accuracy

被引:15
|
作者
Van den Houte, Maaike [1 ,2 ,3 ]
Vlemincx, Elke [4 ]
Franssen, Mathijs [5 ]
Van Diest, Ilse [5 ]
Van Oudenhove, Lukas [2 ,6 ]
Luminet, Olivier [1 ,3 ]
机构
[1] UCLouvain, Res Grp Hlth Emot Cognit & Memory, Res Inst Psychol Sci, Louvain La Neuve, Belgium
[2] Katholieke Univ Leuven, Lab Brain Gut Axis Studies LaBGAS, UZ Herestr 49 Box 7003, B-3000 Leuven, Belgium
[3] Fund Sci Res FRS FNRS, Brussels, Belgium
[4] Vrije Univ Amsterdam, Dept Hlth Sci, Amsterdam, Netherlands
[5] Katholieke Univ Leuven, Hlth Psychol Res Grp, Leuven, Belgium
[6] Dartmouth Coll, Cognit & Affect Neurosci Lab, Hanover, NH 03755 USA
关键词
VALIDATION; PERCEPTION; HEARTBEAT; DISORDER; SCALE;
D O I
10.1111/psyp.13760
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
Interoception, or the sense of the internal state of the body, is hypothesized to be essential for a wide range of psychobiological processes and the development and perpetuation of several (mental) health problems. However, the study of interoceptive accuracy, the objectively measured capacity to detect or discriminate conscious bodily signals, has been hampered by the use of tasks with questionable construct validity and is often limited to studying interoception solely in the cardiac domain. We developed a novel task to measure interoceptive accuracy in the respiratory domain, the respiratory occlusion discrimination (ROD) task. In this task, interoceptive accuracy is defined as an individual's ability to detect small differences in lengths of short respiratory occlusions, assessed by means of an adaptive staircase procedure. This article describes a validation study (N = 97) aimed at investigating the internal consistency, test-retest reliability, and discriminant validity of the ROD task. The average just noticeable difference of lengths of respiratory occlusion was 74.22 ms, with large inter-individual variability (SD = 37.1 ms). The results of the validation study indicate acceptable internal consistency (Cronbach's alpha = 0.70), 1-week test-retest reliability (r = 0.53), and discriminant validity, as indicated by a lack of correlation between the ROD task and an auditory discrimination task with identical design (r = 0.18), and a weak correlation with breathing behavior (r = -0.27). The ROD task is a promising novel paradigm to study interoceptive accuracy and its role in various psychobiological processes and disorders.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] The duration discrimination respiratory task: A new test to measure respiratory interoceptive accuracy
    Bodart, Alice
    Invernizzi, Sandra
    De Leener, Melanie
    Lefebvre, Laurent
    Rossignol, Mandy
    PSYCHOPHYSIOLOGY, 2024, 61 (10)
  • [2] INTEROCEPTIVE FEAR CONDITIONING: A NEW PARADIGM WITH RESPIRATORY STIMULI
    Van Diest, Ilse
    Pappens, Meike
    Smets, Elyn
    Vansteenwegen, Debora
    Van den Bergh, Omer
    PSYCHOPHYSIOLOGY, 2011, 48 : S6 - S6
  • [3] Follow your breath: Respiratory interoceptive accuracy in experienced meditators
    Daubenmier, Jennifer
    Sze, Jocelyn
    Kerr, Catherine E.
    Kemeny, Margaret E.
    Mehling, Wolf
    PSYCHOPHYSIOLOGY, 2013, 50 (08) : 777 - 789
  • [4] Comparison of respiratory interoceptive accuracy with other organ domains: A scoping review
    Eimer, Tabea
    Bernard, Sam
    Schulz, Andre
    Guadagnoli, Livia
    van den Houte, Maaike
    Van Oudenhove, Lukas
    von Leupoldt, Andreas
    Weltens, Nathalie
    BIOLOGICAL PSYCHOLOGY, 2024, 193 : 10 - 11
  • [5] The heart rate discrimination task: A psychophysical method to estimate the accuracy and precision of interoceptive beliefs
    Legrand, Nicolas
    Nikolova, Niia
    Correa, Camile
    Braendholt, Malthe
    Stuckert, Anna
    Kildahl, Nanna
    Vejlo, Melina
    Fardo, Francesca
    Allen, Micah
    BIOLOGICAL PSYCHOLOGY, 2022, 168
  • [6] The effects of acute stress on interoceptive learning and somatic complaints in a differential respiratory conditioning paradigm
    Mueller, Ruta
    van Diest, Ilse
    Vogele, Claus
    Schulz, Andre
    BIOLOGICAL PSYCHOLOGY, 2024, 193 : 16 - 16
  • [7] MOUTH OCCLUSION PRESSURE AS A MEASURE OF RESPIRATORY CENTER OUTPUT IN MAN
    BURKI, NK
    MITCHELL, LK
    CHAUDHARY, B
    ZECHMAN, FW
    FEDERATION PROCEEDINGS, 1976, 35 (03) : 634 - 634
  • [8] OCCLUSION PRESSURE AS A MEASURE OF RESPIRATORY CENTER OUTPUT IN CONSCIOUS MAN
    WHITELAW, WA
    DERENNE, JP
    MILICEMILI, J
    RESPIRATION PHYSIOLOGY, 1975, 23 (02): : 181 - 199
  • [9] OCCLUSION PRESSURE AS A MEASURE OF RESPIRATORY CENTER OUTPUT IN CONSCIOUS MAN
    WHITELAW, WA
    DERENNE, JP
    MILICEMILI, J
    BULLETIN DE PHYSIO-PATHOLOGIE RESPIRATOIRE, 1975, 11 (02): : P77 - P78
  • [10] ACUTE STRESS AFTER HEARTBEAT PERCEPTION TRAINING INCREASES INTEROCEPTIVE ACCURACY IN THE HEARTBEAT COUNTING TASK, BUT NOT IN THE HEARTBEAT DISCRIMINATION TASK
    Mueller, Ruta
    Voegele, Claus
    van Diest, Ilse
    Le, Madeleine
    Bis, Pauline
    Schulz, Andre
    PSYCHOPHYSIOLOGY, 2023, 60 : S117 - S118