Non-invasive measurement of cardiac output: Evaluation of new infrared absorption spectrometer

被引:2
|
作者
Baum, M. M.
Moss, J. A.
Kumar, S.
Wagner, P. D.
机构
[1] Oak Crest Inst Sci, Dept Chem, Pasadena, CA 91107 USA
[2] Univ Calif San Diego, Sch Med, Div Physiol, La Jolla, CA 92093 USA
关键词
infrared spectroscopy; open-circuit; inert gas;
D O I
10.1016/j.resp.2005.09.010
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The mass spectrometer (MS) traditionally has been the instrument of choice for measuring cardiac Output (Q(T)) non-invasively using the foreign gas uptake method. However, the size and cost of the MS has hampered widespread adoption of this technique outside of the laboratory. Here, we present results, from six normal human subjects at rest and during exercise, of simultaneous QT measurements by an MS and a new, portable infrared (IR) device developed in our laboratories. These measurements are made using on the open-circuit acetylene uptake method. The IR device measures inspired and end-tidal concentrations of acetylene, sulfur hexafluoride, and carbon dioxide by IR absorption spectroscopy with a 10-90% response time of 43 ms; accurate measurements were made down to sample flow rates of 50 mL min(-1). Excellent correlation [Q(T) (IR) = 0-98 QT (MS), R-2 = 0.94] was observed between instruments across the range from rest to heavy exercise. These results suggest that the IR device, which is small, light-weight, and rugged may enable the foreign gas uptake method to be used in clinical, field, and point-of-care settings for QT measurement. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:191 / 201
页数:11
相关论文
共 50 条
  • [21] Non-invasive cardiac output evaluation during progressive exercise test
    Richard, R
    Lonsdorfer-Wolf, E
    Charloux, A
    Oswald-Mammoser, M
    Mettauer, B
    Lampert, E
    Lonsdorfer, J
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2000, 440 (06): : R268 - R268
  • [22] Continuous non-invasive Measurement of Cardiac Output for internal Intensive Patients: Evaluation of CNAP- Technology
    Saugel, B.
    Grond, J.
    Fortin, J.
    Negulescu, I.
    Schoefthaler, M.
    Wagner, J.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2015, 110 (04) : 315 - 315
  • [23] NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT DURING ANESTHESIA - AN EVALUATION OF THE SOLUBLE GAS UPTAKE METHOD
    HENEGHAN, CPH
    BRANTHWAITE, MA
    BRITISH JOURNAL OF ANAESTHESIA, 1981, 53 (04) : 351 - 355
  • [24] NON-INVASIVE OSCILLOMETRIC CARDIAC OUTPUT CALCULATION
    Reshetnik, A.
    Schoelzel, A.
    Compton, F.
    Toelle, M.
    Zidek, M.
    van der Giet, M.
    JOURNAL OF HYPERTENSION, 2017, 35 : E120 - E120
  • [25] Non-invasive assessment of cardiac output in children
    Richardson, JR
    Ferguson, J
    Hiscox, J
    Rawles, J
    JOURNAL OF ACCIDENT & EMERGENCY MEDICINE, 1998, 15 (05): : 304 - 307
  • [26] Use of a Non-invasive Cardiac Output Measurement in a Patient with Low-output Dilated Cardiomyopathy
    Nakayama, Atsuko
    Iwama, Kentaro
    Makise, Naohiro
    Domoto, Yukako
    Ishida, Junichi
    Morita, Hiroyuki
    Komuro, Issei
    INTERNAL MEDICINE, 2020, 59 (12) : 1525 - 1530
  • [27] Non-invasive cardiac output assessment in children
    Childs, C
    Dark, P
    JOURNAL OF ACCIDENT & EMERGENCY MEDICINE, 1999, 16 (02): : 158 - 158
  • [28] Search for a non-invasive cardiac output monitor
    Thom, Ogilvie
    EMERGENCY MEDICINE AUSTRALASIA, 2008, 20 (03) : 199 - 200
  • [29] Non-invasive cardiac output (NICO) monitor
    Sutton, D
    ANAESTHESIA AND INTENSIVE CARE, 2001, 29 (01) : 81 - 81
  • [30] Non-invasive cardiac output monitoring in neonates
    Meyer, Sascha
    Todd, David
    Shadboldt, Bruce
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2010, 95 (06): : F464 - F464