Comparative study of conductivity in mid-voltage cable XLPE insulation

被引:0
|
作者
Frutos, F [1 ]
Acedo, M [1 ]
Jadraque, A [1 ]
Mudarra, M [1 ]
Sellarès, J [1 ]
Belana, J [1 ]
机构
[1] Univ Sevilla, Depto Fis Aplicada 1, Seville 41012, Spain
关键词
D O I
10.1109/ICSD.2004.1350304
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
It is well established that space charge conditions insulation lifetime. Because of this, space charge formation and relaxation processes characterization has become a very active research field, not only from an basic science point of view, but also in order to improve insulation performance in cable and other devices. In the case of mid-voltage power cable, crosslinked polyethylene is widely used as insulator. Service temperature of such cables is around 90degreesC, which in the case of the cable insulation studied is in the melting temperature range. In previous works it has been determined that at this temperature conductivity plays a relevant role in the space charge relaxation process, so that the characterization of conductive processes at service temperature may become important in order to enhance cable insulation performance. The aim of this work is to contribute to a better knowledge of the conductive properties of XLPE in both time and frequency domains.
引用
收藏
页码:119 / 122
页数:4
相关论文
共 50 条
  • [31] Electrical treeing caused by rapid DC-Voltage grounding of XLPE cable insulation
    Selsjord, Mildrid
    Ildstad, Erling
    [J]. CONFERENCE RECORD OF THE 2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2006, : 502 - +
  • [32] Electrical Tree Growth Characteristics in XLPE Cable Insulation under DC Voltage Conditions
    Liu, Ying
    Cao, Xiaolong
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (06) : 3676 - 3684
  • [33] Study on molded joint by curable pe block insulation for xlpe insulating cable under extra high voltage
    Toya, A
    Kurihara, M
    Shimomura, T
    Kondo, K
    Nakamura, S
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (02) : 669 - 675
  • [34] Analysis and Compare for Voltage Levels of The Mid-voltage Distribution Network
    Tang Bo
    Hu Peng
    Fu Yang
    Cao Wang-shu
    [J]. 2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [35] Breakdown mechanisms of XLPE cable with insulation defects
    Arachchige, Thanuja Gawasingha
    Narampanawa, Lakshitha
    Ekanayake, Chandima
    Ma, Hui
    [J]. 2020 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (2020 IEEE CEIDP), 2020, : 71 - 74
  • [36] LOCATION AND EXAMINATION OF DEFECTS IN XLPE CABLE INSULATION
    HAGEN, ST
    ILDSTAD, E
    SLETBAK, J
    FAREMO, H
    [J]. PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN SOLID DIELECTRICS, 1989, : 569 - 573
  • [37] Effect of water on aging of XLPE cable insulation
    Nikolajevic, SV
    Drca, R
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2001, 60 (01) : 9 - 15
  • [38] Study of an Initial Transient Relaxation in XLPE Cable Insulation by TSDC and PEA
    Belana, J.
    Diego, J. A.
    Orrit, J.
    Tamayo, I.
    Mudarra, M.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (06) : 2074 - 2082
  • [39] Study of Dielectric Response Characteristics for Thermal Aging of XLPE Cable Insulation
    Wang, Y.
    Zhao, A.
    Zhang, X.
    Shen, Y.
    Yang, F.
    Deng, J.
    Zhang, G.
    [J]. 2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 602 - 605
  • [40] Effect of Tree Channel Conductivity on Electrical Tree Shape and Breakdown in XLPE Cable Insulation Samples
    Chen, Xiangrong
    Xu, Yang
    Cao, Xiaolong
    Dodd, S. J.
    Dissado, L. A.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (03) : 847 - 860