Real-Time fast PCR amplification using designated and conventional real time thermal cycler systems: COVID-19 perspective

被引:6
|
作者
Hossain, Walid [1 ]
Hossain, Mohabbat [2 ]
Arafath, Khalid [1 ]
Ety, Subarna Sayed [1 ]
Shetu, Mahade Hasan [1 ]
Kabir, Mazbahul [1 ]
Noor, Farjana Akther [1 ,3 ]
Mannoor, Kalissar [1 ]
机构
[1] OMC Healthcare Pvt Ltd, Mol Biol Lab, Dhaka, Bangladesh
[2] Inst Developing Sci & Hlth Initiat, Infect Dis Lab, Dhaka, Bangladesh
[3] Tejgaon Coll, Dept Biochem & Mol Biol, Dhaka, Bangladesh
来源
PLOS ONE | 2022年 / 17卷 / 10期
关键词
D O I
10.1371/journal.pone.0276464
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The study aimed to shorten multiplex RT-PCR run time for detection of SARS CoV-2 N1 and N2 sequences and human RNase P (RP) sequence as internal mRNA control using conventional and designated real time thermal cycler systems. Optimization of Fast PCR protocol using plasmid-based N1 and N2 positive control and synthetic version of human RP was done on Applied Biosystems (ABI) QuantStudio(TM)5 (conventional), ABI 7500 Fast Dx (designated), and CFX96 Touch Real Time Detection System, Bio-Rad (conventional). Finally, a performance evaluation of Fast PCR was performed in terms of sensitivity, specificity, and precision. For a 40-cycle PCR with optimized Fast PCR protocols on QuantStudio(TM)5, ABI 7500 Fast Dx, and CFX96 Touch (conventional), standard/regular versus Fast PCR run times (min) were 84 vs. 49, 96 vs. 48, and 103 vs. 61, thereby saving 35, 48, and 43 min, respectively. For each thermal cycler, Standard and Fast PCR generated identical shapes of fluorescence curves, Ct values, and (3) R-2 (0.95 to 0.99) for 5 10-log dilution panels of each positive control. The fast PCR approach generated results with 100% sensitivity and specificity. Median test comparisons between standard PCR and Fast PCR Cts of COVID-19 samples did not produce significance (p>0.5), suggesting that Fast PCR and Standard PCR were comparable. Also, the median and mean of each target had closely-related values, further suggesting that the two approaches were comparable. That is, there is an equivalency between Conventional and Fast PCR instruments for detection of COVID-19.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Specification and analysis of real-time systems using Real-Time Maude
    Ölveczky, PC
    Meseguer, J
    FUNDAMENTAL APPROACHES TO SOFTWARE ENGINEERING, PROCEEDINGS, 2004, 2984 : 354 - 358
  • [32] Evaluating the efficiency of specimen (sample) pooling for real-time PCR based diagnosis of COVID-19
    Shukla, Surabhi
    Upadhyay, Vandana
    Maurya, Vinod Kumar
    INDIAN JOURNAL OF MEDICAL MICROBIOLOGY, 2021, 39 (03) : 339 - 342
  • [33] Three Novel Real-Time RT-PCR Assays for Detection of COVID-19 Virus
    Niu, Peihua
    Lu, Roujian
    Li Zhao
    Wang, Huijuan
    Huang, Baoying
    Ye, Fei
    Wang, Wenling
    Tan, Wenjie
    CHINA CDC WEEKLY, 2020, 2 (25): : 453 - 457
  • [34] REAL-TIME MECHANISTIC BAYESIAN FORECASTS OF COVID-19 MORTALITY
    Gibson, Graham C.
    Reich, Nicholas G.
    Sheldon, Daniel
    ANNALS OF APPLIED STATISTICS, 2023, 17 (03): : 1801 - 1819
  • [35] Real-time observations of the impact of COVID-19 on underwater noisea)
    Thomson, Dugald J. M.
    Barclay, David R.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2020, 147 (05): : 3390 - 3396
  • [36] Real-time face mask detection for COVID-19 prevention
    Sujon, Mohammad Rezaul Karim
    Hossain, Md Rasel
    Al Amin, Md Jaki
    Bepery, Chinmay
    Rahman, Md Mahbubur
    2022 IEEE 12TH ANNUAL COMPUTING AND COMMUNICATION WORKSHOP AND CONFERENCE (CCWC), 2022, : 341 - 346
  • [37] An intelligent garment for long COVID-19 real-time monitoring
    Nkengue, Marc Junior
    Zeng, Xianyi
    Koehl, Ludovic
    Tao, Xuyuan
    Dassonville, François
    Dumont, Nicolas
    Ye-Lehmann, Shixin
    Akwa, Yvette
    Ye, Hanwen
    Computers in Biology and Medicine, 2024, 181
  • [38] Towards a ubiquitous real-time COVID-19 detection system
    Sbai, Mohamed
    Taktak, Hajer
    Moussa, Faouzi
    INTERNATIONAL JOURNAL OF PERVASIVE COMPUTING AND COMMUNICATIONS, 2022, 18 (02) : 211 - 225
  • [39] Real-time observations of the impact of COVID-19 on underwater noise
    Thomson, Dugald J. M.
    Barclay, David R.
    Journal of the Acoustical Society of America, 2020, 147 (05): : 3390 - 3396
  • [40] Quantitative real-time PCR is not more sensitive than "Conventional" PCR
    Bastien, Patrick
    Procop, Gary W.
    Reischl, Udo
    JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (06) : 1897 - 1900