Transmission Capability Improvement using Wide Area Monitoring and Control

被引:0
|
作者
Karimi, M. J. [1 ]
Ranjbar, A. M. [1 ]
Nourizadeh, S. [1 ]
机构
[1] Sharif Univ Technol, Dept Elect Engn, Tehran, Iran
关键词
phasor measurement unit; Power system dynamic stability; power system oscillation; power system stabilizer; transmission capability; Wide Area Monitoring and Control;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Operation of transmission lines are usually limited by stability limits rather than thermal capacity limits. Thermal limit of transmission lines is a physical limitation of their components and not related with the overall power system characteristics, but stability limits are strictly related with power system characteristics. This paper presents an approach for increasing stability limits using PSS.
引用
收藏
页码:299 / 303
页数:5
相关论文
共 50 条
  • [1] Wide Area Monitoring, Protection and Control
    Begovic, Miroslav M.
    Messina, Arturo R.
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2010, 4 (10) : 1083 - 1085
  • [2] Wide area system monitoring and control
    Karlsson, Daniel
    Hemmingsson, Morten
    Lindahl, Sture
    [J]. IEEE Power and Energy Magazine, 2004, 2 (05): : 68 - 76
  • [3] Latency Characterization of a Wide Area Monitoring Protection and Control Application in the Italian Transmission System
    Castello, Paolo
    Gallus, Giacomo
    Muscas, Carlo
    Pegoraro, Paolo Attilio
    Sitzia, Davide
    Campisano, Laura
    Giannuzzi, Giorgio Maria
    Maiolini, Camilla
    Pau, Pietro
    [J]. 2022 IEEE 12TH INTERNATIONAL WORKSHOP ON APPLIED MEASUREMENTS FOR POWER SYSTEMS (AMPS), 2022,
  • [4] Control and Monitoring of Power Transmission Lines Condition over Wide Area with the Help of UAVs
    Rezinkina, Marina
    Rezinkin, Oleg
    Karpaliuk, Igor
    Grabko, Volodymyr
    [J]. 2020 IEEE 7TH INTERNATIONAL CONFERENCE ON ENERGY SMART SYSTEMS (2020 IEEE ESS), 2020, : 172 - 175
  • [5] USING WIDE AREA MONITORING WSN
    Padwal, Sonar
    Holkar, Ashwini
    Khote, Shubhangi
    Maral, Prajakta
    Kadam, Vidya
    [J]. 2017 INTERNATIONAL CONFERENCE ON INFORMATION COMMUNICATION AND EMBEDDED SYSTEMS (ICICES), 2017,
  • [6] Wide area voltage sag control in transmission lines using modified UPFC
    Ranjbar, Soheil
    [J]. ELECTRICAL ENGINEERING, 2023, 105 (5) : 2675 - 2685
  • [7] Wide area voltage sag control in transmission lines using modified UPFC
    Soheil Ranjbar
    [J]. Electrical Engineering, 2023, 105 : 2675 - 2685
  • [8] Vulnerability evaluation for monitoring wide area outage in transmission systems
    Kim, Jin Hwan
    Lim, Il Hyung
    Lee, Seung Jae
    Choi, Myeon Song
    Lim, Seong Il
    Kim, Sang Tae
    Jin, Bo Gun
    [J]. Transactions of the Korean Institute of Electrical Engineers, 2010, 59 (03): : 506 - 514
  • [9] Wide area monitoring system (WAMS) for the Czech transmission grid
    Sadecky, Bohumil
    Havrda, Marek
    Wittassek, Tomas
    [J]. PROCEEDINGS OF THE 7TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2013), 2013, : 504 - 507
  • [10] Instantaneous Response of Wide Area Intrusion Sensor With Long Haul Monitoring Capability
    Pua, Chang Hong
    Chong, Wu Yi
    Ahmad, Harith
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2013, 25 (23) : 2255 - 2258