Vulnerability evaluation for monitoring wide area outage in transmission systems

被引:0
|
作者
Kim, Jin Hwan
Lim, Il Hyung
Lee, Seung Jae
Choi, Myeon Song
Lim, Seong Il
Kim, Sang Tae
Jin, Bo Gun
机构
关键词
C (programming language) - Electric load flow - Electric power transmission networks - Electric power transmission;
D O I
暂无
中图分类号
学科分类号
摘要
Defense systems are needed to prevent catastrophic failures of a power grid due to cascaded events. Cascaded events can be occurred by power flow overload. Especially, it is the most dangerous problem that overload line is outage, because it can make the power system face danger of cascaded. In this paper, vulnerability evaluation for monitoring wide are outage is proposed using by configuration information of transmission systems. This method of vulnerability evaluation is considered direct effect and indirect effect of power flow, especially overload. What is more, it can be used when the configuration of power system changes, as simple fault occurs or maintenance of facility. In the case studies, the estimation and simulation network have been testified and analysed in PSSE and C programming.
引用
收藏
页码:506 / 514
相关论文
共 50 条
  • [1] Wide-Area Line Outage Monitoring by Sparse Phasor Measurements
    Azizi, Sadegh
    Jegarluei, Mohammad Rezaei
    Kettner, Andreas Martin
    Dobakhshari, Ahmad Salehi
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2023, 38 (04) : 3621 - 3631
  • [2] On PMU Location Selection for Line Outage Detection in Wide-area Transmission Networks
    Zhao, Yue
    Goldsmith, Andrea
    Poor, H. Vincent
    [J]. 2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [3] Transmission Capability Improvement using Wide Area Monitoring and Control
    Karimi, M. J.
    Ranjbar, A. M.
    Nourizadeh, S.
    [J]. 2008 IEEE ELECTRICAL POWER AND ENERGY CONFERENCE, 2008, : 299 - 303
  • [4] Wide area monitoring system (WAMS) for the Czech transmission grid
    Sadecky, Bohumil
    Havrda, Marek
    Wittassek, Tomas
    [J]. PROCEEDINGS OF THE 7TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2013), 2013, : 504 - 507
  • [5] EVALUATION OF THE MARGINAL OUTAGE COSTS IN COMPOSITE GENERATION AND TRANSMISSION-SYSTEMS
    GHAJAR, R
    BILLINTON, R
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 1994, 31 (02) : 79 - 86
  • [6] Implementation and Applications of Wide-area monitoring systems
    Larsson, Mats
    Korba, Petr
    Zima, Marek
    [J]. 2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 669 - +
  • [7] Out of Step technique based Wide Area Monitoring in Transmission Line
    Datta, Devarshi
    Mohapatra, Srikant
    Mohanty, Subodh Kumar
    [J]. 2019 INNOVATIONS IN POWER AND ADVANCED COMPUTING TECHNOLOGIES (I-PACT), 2019,
  • [8] The View from the Wide Side: Wide-Area Monitoring Systems in India
    Soonee, S.K.
    Agrawal, V.K.
    Agarwal, P.K.
    Narasimhan, S.R.
    Thomas, Mini Shaji
    [J]. IEEE Power and Energy Magazine, 2015, 13 (05): : 49 - 59
  • [9] Towards DDoS Attack Resilient Wide Area Monitoring Systems
    Demir, Kubilay
    Suri, Neeraj
    [J]. PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON AVAILABILITY, RELIABILITY AND SECURITY (ARES 2017), 2017,
  • [10] Frequency Estimation in Power Systems for Wide Area Monitoring and Control
    Kumar, V. Seshadri Sravan
    Kumar, G. Manoj
    Kumar, A. Santosh
    Thukaram, D.
    [J]. 2016 IEEE ANNUAL INDIA CONFERENCE (INDICON), 2016,