In vitro post-stenotic flow quantification and validation using echo particle image velocimetry (Echo PIV)

被引:21
|
作者
Walker, Andrew M. [1 ]
Scott, Joel [2 ]
Rival, David E. [1 ]
Johnston, Clifton R. [2 ]
机构
[1] Univ Calgary, Dept Mech & Mfg Engn, Calgary, AB T2N 1N4, Canada
[2] Dalhousie Univ, Dept Mech Engn, Halifax, NS B3H 4R2, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
VELOCITY PROFILES; PULSATILE FLOW; SHEAR-STRESS; STEADY; ARTERY; VISUALIZATION; RESOLUTION; MODEL;
D O I
10.1007/s00348-014-1821-6
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Echo particle image velocimetry (Echo PIV) presents itself as an attractive in vivo flow quantification technique to traditional approaches. Promising results have been acquired; however, limited quantification and validation is available for post-stenotic flows. We focus here on the comprehensive evaluation of in vitro downstream stenotic flow quantified by Echo PIV and validated in relation to digital particle image velocimetry (DPIV). A Newtonian blood analog was circulated through a closed flow loop and quantified immediately downstream of a 50 % axisymmetric blockage at two Reynolds numbers (Re) using time-averaged Echo PIV and DPIV. Centerline velocities were in good agreement at all Re; however, Echo PIV measurements presented with elevated standard deviation (SD) at all measurements points. SD was improved using increased line density (LD); however, frame rate or field of view (FOV) is compromised. Radial velocity profiles showed close agreement with DPIV with the largest disparity in the shear layer and near-wall recirculation. Downstream recirculation zones were resolved by Echo PIV at both Re; however, magnitude and spatial coverage was reduced compared to DPIV that coincided with reduced contrast agent penetration beyond the shear layer. Our findings support the use of increased LD at a cost to FOV and highlight reduced microbubble penetration beyond the shear layer. High local SD at near-wall measurements suggests that further refinement is required before proceeding to in vivo quantification studies of wall shear stress in complex flow environments.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Real-time multi-component Hemodynamic measurement in vascular aneurysms using echo particle image velocimetry:: Comparison of in vitro and computational results
    Liu, Lingli
    Zhang, Fuxing
    Wang, Rui
    Shandas, Robin
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 1097 - 1100
  • [42] Application of particle image velocimetry (PIV) for deformation measurement during granular silo flow
    Slominski, Cezary
    Niedostatkiewicz, Maciej
    Tejchman, Jacek
    [J]. POWDER TECHNOLOGY, 2007, 173 (01) : 1 - 18
  • [43] Flow field investigation of high solid anaerobic digestion by Particle Image Velocimetry (PIV)
    Hu, Yuying
    Wu, Jing
    Poncin, Souhila
    Cao, Zhiping
    Li, Zhonghua
    Li, Huai Z.
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 626 : 592 - 602
  • [44] Ultrasound wave propagation in tissue and scattering from microbubbles for echo particle image velocimetry technique
    Mukdadi, O
    Shandas, R
    [J]. BIOMEDICAL SCIENCES INSTRUMENTATION, VOL 40, 2004, 449 : 364 - 370
  • [45] Flow characteristics in free impinging jet reactor by particle image velocimetry (PIV) investigation
    Zhang, Jun
    Liu, Youzhi
    Qi, Guisheng
    Jiao, Weizhou
    Yuan, Zhiguo
    [J]. FLUID DYNAMICS RESEARCH, 2016, 48 (04)
  • [46] Measurement of red cell velocity in microvessels using particle image velocimetry (PIV)
    Nakano, A
    Sugii, Y
    Minamiyama, M
    Niimi, H
    [J]. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2003, 29 (3-4) : 445 - 455
  • [47] ANALYSIS OF WAKE STRUCTURES IN BUBBLY FLOWS USING PARTICLE IMAGE VELOCIMETRY (PIV)
    Lewandowski, Bjoern
    Fertig, Micha
    Krekel, Georg
    Ulbricht, Mathias
    [J]. CHEMICAL AND PROCESS ENGINEERING-INZYNIERIA CHEMICZNA I PROCESOWA, 2019, 40 (01): : 49 - 55
  • [48] Noninvasive Measurement of Steady and Pulsating Velocity Profiles and Shear Rates in Arteries Using Echo PIV: In Vitro Validation Studies
    Hyoung-Bum Kim
    Jean Hertzberg
    Craig Lanning
    Robin Shandas
    [J]. Annals of Biomedical Engineering, 2004, 32 : 1067 - 1076
  • [49] FLOW CHARACTERISTICS IN THE IMPROVED IMPINGING STREAM REACTOR BY MEANS OF PARTICLE IMAGE VELOCIMETRY (PIV)
    Liu Xueqing
    Lu Luyi
    [J]. PROCEEDINGS OF THE ASME POWER CONFERENCE JOINT WITH ICOPE-17, 2017, VOL 2, 2017,
  • [50] Particle Image Velocimetry (PIV) Investigation of Flow Characteristics in Confined Impinging Jet Reactors
    Gao, Zhengming
    Han, Jing
    Xu, Yingdao
    Bao, Yuyun
    Li, Zhipeng
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2013, 52 (33) : 11779 - 11786