Automated immunomagnetic separation for the detection of Escherichia coli O157:H7 from spinach

被引:22
|
作者
Chen, Jing [1 ,2 ,3 ]
Shi, Xianming [1 ,2 ]
Gehring, Andrew G. [3 ]
Paoli, George C. [3 ]
机构
[1] Shanghai Jiao Tong Univ, MOST USDA, Joint Res Ctr Food Safety, Dept Food Sci & Technol, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, Bar Luh Food Safety Ctr, Shanghai 200240, Peoples R China
[3] USDA ARS ERRC, MOST, Joint Res Ctr Food Safety, Mol Characterizat Foodborne Pathogens Res Unit, Wyndmoor, PA 19038 USA
基金
中国国家自然科学基金;
关键词
E. coli O157:H7; Immunomagnetic separation; Pathogen detection; REAL-TIME PCR; LISTERIA-MONOCYTOGENES; FOOD; O157-H7; PRODUCE; BEADS;
D O I
10.1016/j.ijfoodmicro.2014.03.022
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Escherichia coli 0157:H7 is a major cause of foodborne illness and methods for rapid and sensitive detection of this deadly pathogen are needed to protect consumers. The use of immunomagnetic separation (IMS) for capturing and detecting foodborne pathogens has gained popularity, partially due to the introduction of automated and high throughput IMS instrumentation. Three methods for automated IMS that test different sample volumes, Kingfisher (R) mL, Pathatrix (R) Auto, and Pathatrix (R) Ultra, were compared using microbiological detection of E. coli O157:H7 from buffered peptone water (BPW), in the presence of background microbial flora derived from spinach leaves, and from culture enrichments from artificially contaminated spinach leaves. The average efficiencies of capture of E. coli O157:H7 using the three methods were 32.1%, 3.7%, and 13%, respectively, in BPW; 43.4%, 8.8%, 2.9%, respectively, in the presence of spinach microbial flora; and 63.0%, 7.0%, and 6.3%, respectively, from artificially contaminated spinach. Despite the large differences in IMS capture efficiencies between the KingFisher (R) and two Pathatrix (R) methods, all three methods allowed the detection of E. coli 0157:H7 from spinach that was artificially contaminated with the pathogen at relatively high (25 cfu/30 g sample) and low (1 cfu/30 g sample) levels after 4-6 h of culture enrichment. The differences in capture efficiency were compensated for by the differences in sample volume used by the KingFisher (R) mL (1 mL), Pathatrix (R) Auto (50 mL) and Pathatrix (R) Ultra (250 mL) instruments. Thus, despite the reduced capture efficiencies observed for the Pathatrix (R) methods, the large increase in sample volume results in a greater number of captured cells for downstream detection resulting in improved detection sensitivity. Published by Elsevier B.V.
引用
收藏
页码:33 / 37
页数:5
相关论文
共 50 条
  • [1] Microsystem for the immunomagnetic detection of Escherichia coli O157:H7
    Mujika, M.
    Arana, S.
    Castano, E.
    Tijero, M.
    Vilares, R.
    Ruano-Lopez, J. M.
    Cruz, A.
    Sainz, L.
    Berganza, J.
    [J]. PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2008, 205 (06): : 1478 - 1483
  • [2] Carbon nanotubes for immunomagnetic separation of Escherichia coli O157:H7
    Lin, Y
    Jiang, XP
    Elkin, T
    Fernando, KAS
    Gu, LR
    Taylor, S
    Yang, H
    Jones, E
    Wang, W
    Sun, YP
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2006, 6 (03) : 868 - 871
  • [3] Immunomagnetic separation and flow cytometry for rapid detection of Escherichia coli O157:H7
    Seo, KH
    Brackett, RE
    Frank, JF
    Hilliard, S
    [J]. JOURNAL OF FOOD PROTECTION, 1998, 61 (07) : 812 - 816
  • [4] Detection of Escherichia coli O157:H7 using immunomagnetic separation and absorbance measurement
    Liu, YC
    Li, YB
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2002, 51 (03) : 369 - 377
  • [5] Quantum dot biolabeling coupled with immunomagnetic separation for detection of Escherichia coli O157:H7
    Su, XL
    Li, YB
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (16) : 4806 - 4810
  • [6] Detection of Escherichia coli O157:H7 Using Automated Immunomagnetic Separation and Enzyme-Based Colorimetric Assay
    Park, Ji Young
    Park, Kisang
    Ok, Gyeongsik
    Chang, Hyun-Joo
    Park, Tae Jung
    Choi, Sung-Wook
    Lim, Min-Cheol
    [J]. SENSORS, 2020, 20 (05)
  • [7] Immunomagnetic separation of Escherichia coli O157:H7 from environmental and wastewater in South Africa
    Müller, EE
    Grabow, WOK
    Ehlers, MM
    [J]. WATER SA, 2003, 29 (04) : 427 - 432
  • [8] Application of Immunomagnetic Separation to E. coli O157: H7 Detection
    Tang Qian-qian
    Wang Jian-ping
    Ye Zun-zhong
    Gai Ling
    Ying Yi-bin
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (10) : 2614 - 2618
  • [9] Improvement of Immunomagnetic separation for Escherichia coli O157:H7 detection by the PickPen magnetic particle separation device
    Nou, Xiangwu
    Arthur, Terrance M.
    Bosilevac, Joseph M.
    Brichta-Harhay, Dayna M.
    Guerini, Michael N.
    Kalchayanand, Norasak
    Koohmaraie, Mohammad
    [J]. JOURNAL OF FOOD PROTECTION, 2006, 69 (12) : 2870 - 2874
  • [10] Rapid detection of Escherichia coli O157:H7 by immunomagnetic separation and real-time PCR
    Fu, Z
    Rogelj, S
    Kieft, TL
    [J]. INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2005, 99 (01) : 47 - 57